Page 61

PROGRAMMING PROCEDURES 
SECTION 300-006-300 
MAY 1986 
TABLE 2 
INITIALIZED DATA (continued) 
05 Program 
Automatic Recall From Hold Timing 0#5 Program 
Camp-on Timeout 
Recall time = 32 seconds Timeout = 32 seconds 
CO LINE OPTIONS 
06 Program 
Automatic Release On Hold Enable 
Disabled = All CO lines 
07 Program 
Automatic Release On Hold Timing 
ESS Timing = All CO lines 
09,09X Program 
CO Line Group Selection 
Dial 9 group = All CO lines 
0#9 Program 
OPL Line Hunting 
Hunting = Not assigned 
100...

Page 62

PROGRAMMING PROCEDURES 
SECTION 300-006-300 
MAY 1986 
TABLE 2 
INITIALIZED DATA (continued) 
STATION OPTIONS 
4XX Program 
Station Type Assignments 
1 O-key assigned = All stations 
CO 1 Start = All stations 
4#XX 
Program 
Station Flexible Key Assignment 
Assignment = Basic key strip 
5XX 
Program 
Station Class of Service #l 
Privacy Override = Not allowed, all stations 
DND Override = Not allowed, all stations 
Executive Override= Not allowed, all stations 
Door phone ring A, B, C = Not selected, all...

Page 63

PROGRAMMING PROCEDURES 
SECTION 300-006-300 
MAY 
1986 
Table Title 
Program 
Page 
3 
4 
: 
7 
8 
9 
10 
11 
12 
13 
14 
15 
16 
17 
18 
19 
20 
21 
22 
23 
4’: 24 
..- 
25 
26 
27 
28 
29 
30 
31 
z: 
34 
35 
36 
37 
38 
39 System Assignments (Basic) 
System Assignments (Options) 
Account Code Digit Length 
System Assignments (Options) 
VCOU MF/DP Outpulsing Selection 
Automatic Recall From Hold Timing 
Camp-on Timeout 
AROH Enable 
AROH Timing 
Night Ring Over External Page 
Single CO Line (Dial 9)...

Page 64

PROGRAMMING PROCEDURES 
SECTION 300-006-300 
MAY 1986 
TABLE 3 
PROGRAM 01 
SYSTEM ASSIGNMENTS (BASIC) 
SET LED on. 
1) Lock in the 
SET switch on the HKSU. Station 17 REP LED on. 
System is in program mode. 
2) Depress the m key on station 17. 
3) Dial 4 0 on the dial pad. Normal functions halt on station 17. 
SPKR LED steady on. 
SPKR LED flashes continuously. 
The various LEDs (see below) will indicate pres- 
ent data. 
4) Refer to the System Record Sheet. 
Using the various keys, turn the associated...

Page 65

PROGRAMMING PROCEDURES 
SECTION 300-006-300 
MAY 1986 
TABLE 4 
PROGRAM 02 
SYSTEM ASSIGNMENTS (OPTIONS) 
SET LED on. 
1) Lock in the 
SET switch on the HKSU. Station 17 REP LED on. 
System is in program mode. 
Normal functions halt on station 17. 
2) SPKR LED steady on. 
3) Dial 0 1 on dial pad. SPKR LED flashes continuously. 
The various LEDs (see below) will indicate pres- 
ent data. 
4) Refer to the System Record Sheet. 
Using the various keys, turn the associated 
LEDs on or off, as required. The...

Page 66

PROGRAMMING PROCEDURES 
SECTION 300-006-300 
MAY 1986 
TABLE 5 
PROGRAM 0#2 
ACCOUNT CODE DIGIT LENGTH ASSIGNMENT 
SET L.ED on. 
1) Lock in the 
SET switch on the HKSU. Station 17 REP LED on. 
System is in program mode. 
2) Depress the m key on station 17. 
3) Dial a fl 1 on the dial pad. Normal functions halt on station 17. 
SPKR LED steady on. 
SPKR LED flashes continuously. 
The various LEDs (see below) will indicate pres- 
ent data. 
4) Refer to the System Record Sheet. Using If the LED is already...

Page 67

PROGRAMMING PROCEDURES 
SECTION 300-006-300 
MAY 1986 
TABLE 6 
PROGRAM 03 
SYSTEM ASSIGNMENTS (OPTIONS) 
SET LED on. 
1) Lock in the 
SET switch on the HSKU. Station 17 REP LED on. 
System is in program mode. 
Normal functions halt on station 17. 
m key on station 17. 
2) Depress the 
l 
3) Dial m a on the dial pad. SPKR LED flashes continuously. 
CO, DND & MW/FL LEDs will be on according 
to present data. 
4) Refer to the System Record Sheet. 
An X on the record sheet means the LED should 
Using the...

Page 68

PROGRAMMING PROCEDURES 
SECTION 300-006-300 
MAY 1986 
TABLE 7 
PROGRAM 04 
VCOU MF/DP OUTPULSING SELECTION 
SET LED on. 
1) Lock in the 
SET switch on the HKSU. Station 17 REP LED on. 
System is in program mode. 
2) Depress the w key on station 17. 
3) Dial m a on the dial pad. 
4) Refer to the System Record Sheet. 
Each CO line represents itself: 
l LED OFF = DTMF 
B LED ON = DP Normal functions halt on station 17. 
SPKR LED steady on. 
SPKR LED flashes continuously. 
CO LEDs go on according to present...

Page 69

TABLE 8 
PROGRAM 05 PROGRAMMING PROCEDURES 
SECTION 300-006-300 
MAY 1966 
AUTOMATIC RECALL FROM HOLD TIMING 
(This program is used only if MW/FL, AD I and AD 2 LEDs are ALL off in Program 5Xx.) 
SET LED on. 
1) Lock in the SET switch on the HKSU 
. 
2) Depress them key on station 17. 
3) Dial g 1 on the dial pad. Station 17 REP LED on. 
System is in program mode. 
Normal functions halt on station 17. 
SPKR LED steady on. 
SPKR LED flashes continuously. 
An INT, CO or ACB LED will be on according to...

Page 70

PROGRAMMING PROCEDURES 
SECTION 300-006-300 
MAY 1986 
TABLE 9 
PROGRAM 0#5 
CAMP-ON TIMEOUT 
SET LED on. 
1) Lock in the SET switch on the HKSU . 
2) Depress the m key on station 17. 
3) Dial 1 fi g on the dial pad. Station 17 REP LED on. 
System is in program mode. 
Normal functions halt on station 17. 
SPKR LED steady on. 
SPKR LED flashes continuously. 
The INT or a CO LED will go on according to 
present data. 
4) Refer to the System Record Sheet. 
Using the various keys, turn one associated 
LED on...
Start reading Toshiba Strata Vie General Description Manual

Related Manuals for Toshiba Strata Vie General Description Manual

All Toshiba manuals