Home > GE > Medical Equipment > GE S5 Service Manual

GE S5 Service Manual

    Download as PDF Print this page Share this page

    Have a look at the manual GE S5 Service Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 45 GE manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Appendix B, ElectroMagnetic Compatibility
    B-5
    Document no. M1031517-02
    Table 4 Recommended separation distances between portable and mobile RF 
    communications equipment and the S/5™ CAM/ CCCM
     (1  For impedance RESP measurement. For invasive pressure measurement in M-series modules 
    except M-PRE(S)TN. The invasive pressure measurement compliance level is dependent on the 
    transducer used, and only the lower level is guaranteed for all transducers.  
      (2 For BIS measurement in E-BIS/M-BIS, RESP measurement in M-(P)RE(S)TN and invasive 
    pressure measurement in M-COPSv/E-COPSv and M-COP/E-COP modules. The invasive 
    pressure measurement compliance level is dependent on the transducer used, and only the 
    lower level is guaranteed for all transducers.
    Recommended separation distances between portable and mobile RF communications 
    equipment and the S/5™ CAM/ CCCM.
    The S/5™ CAM/ CCCM is intended for use in an electromagnetic environment in which radiated RF disturbances are 
    controlled. The customer or the user of the S/5™ CAM/ CCCM can help prevent electromagnetic interference by 
    maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and 
    the S/5™ CAM/ CCCM as recommended below, according to the maximum output power of the communications 
    equipment.
    Rated maximum output 
    power of transmitter
    WSeparation distance according to frequency of transmitter
    m
    150 kHz to 80 MHz
     
     (1 80 MHz to 800 MHz
      (2 80 MHz to 800 MHz
      (2 
    0.01 0.12
      0.35
      (1 0.12
      0.35  (2 0.23
       0.70  (2 
    0.1 0.38
      1.1
      (1 0.38
     1.1 (2 0.73
     2.2 (2 
    11.2
      3.5
      (1 1.2
       3.5 (2 2.3
       7.0 (2 
    10 3.8
    11
     (1 3.8
     11 (2 7.3
    22 (2 
    100 12
        35
      (1 12
        35  (2 23
      70 (2 
    For transmitters rated at a maximum output power not listed above, the recommended separation distance d in 
    meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the 
    maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
    NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
    NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption 
    and reflection from structures, objects and people.
    d1.2P =
    d3.5P =
    d1.2P =
    d3.5P =
    d2.3P =
    d7P = 
    						
    							 
    B-6
    Document no.  M1031517-02
    For your notes: 
    						
    							All specifications are subject to change without notice.
    CAUTION: U.S. Federal law restricts this device to sale by or on the order of a licensed medical practitioner.
    Outside the USA, check local laws for any restriction that may apply.
    Document no. M1031518-02
    March, 2006
    Datex-Ohmeda Inc.
    P.O. Box 7550
    Madison, WI 53707-7550, USA
    Tel: +1 608 221 1551
    Fax: +1 608 222 9147
    GE Healthcare Finland Oy
    Helsinki, Finland
    P.O. Box 900
    FI-00031 GE, FINLAND
    Tel: +358 10 39411
    Fax: +358 9 1463310
     www.gehealthcare.com
    Copyright  2006 General Electric Company
    Datex-Ohmeda
    S/5
    TM Compact Anesthesia Monitor
    S/5
    TM Compact Critical Care Monitor
    Planned Maintenance Instructions 
    						
    							Table of contents
    i
                                                                                      Document no. M1031518-02
    Table of contents
    Table of contents i
    1 Planned maintenance instructions 1
    1.1 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
    1.2 Recommended tools  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
    1.2.1 Hemodynamic patient simulators  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
    1.3 Recommended parts  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
    1.4 Planned maintenance parts  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
    1.4.1 PM parts for Compact Airway Modules, E-CXXXXX/ M-CXXXXX without CO2 absorber
     - Anesthesia  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
    1.4.2 PM parts for Compact Airway Modules, E-CXXXXX/ M-CXXXXX without CO2 absorber
     - Critical Care. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
    1.4.3 PM parts for Compact Airway Modules, E-CXXXXX/ M-CXXXXX with CO2 absorber
     - Anesthesia  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
    1.4.4 PM parts for Compact Airway Modules, E-CXXXXX/ M-CXXXXX with CO2 absorber
     - Critical Care. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
    1.4.5 PM parts for Airway Module, E-miniC/ M-miniC  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
    2 Planned maintenance check list 8
    2.1 Visual inspection/preparation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
    2.1.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
    2.1.2 Compact Airway Module, E-CXXXXX/ M-CXXXXX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
    2.1.3 Single-width Airway Module, E-miniC/ M-miniC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
    2.1.4 Tonometry Module, E-TONO/ M-TONO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
    2.1.5 Recorder Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
    2.1.6 Modules with NIBP measurement  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
    2.2 Functional inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
    2.2.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
    2.2.2 Display  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
    2.2.3 Keyboard(s)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
    2.2.4 Display Unit  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
    2.2.5 Frame Unit  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
    2.2.6 Compact Airway Module, E-CXXXXX/ M-CXXXXX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
    2.2.7 Single-width Airway Module, E-miniC/ M-miniC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
    2.2.8 Tonometry Module, E-TONO/ M-TONO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
    2.2.9 Multiparameter Hemodynamic Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
    2.2.10 EEG Module, E-EEG/ M-EEG and EEG Headbox, N-EEG. . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
    2.2.11 BIS Module, E-BIS/ M-BIS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
    2.2.12 Entropy Module, E-ENTROPY/ M-ENTROPY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
    2.2.13 Pressure/Pressure Temp Modules, E-P, E-PT, M-P, M-PT. . . . . . . . . . . . . . . . . . . . . . . . . . . .19
    2.2.14 Dual pressure Module, E-PP, M-PP  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
    2.2.15 Cardiac Output Modules, E-COP, E-COPSv, M-COP, M-COPSv  . . . . . . . . . . . . . . . . . . . . . . .19
    2.2.16 NIBP module, M-NIBP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
    2.2.17 NeuroMuscular Module, E-NMT, M-NMT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
    2.2.18 Nellcor Compatible Saturation module, E-NSAT, M-NSAT. . . . . . . . . . . . . . . . . . . . . . . . . . .21
    2.2.19 Datex-Ohmeda Oxygen Saturation module, M-OSAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 
    						
    							Datex-Ohmeda S/5 Compact Anesthesia and Compact Critical Care Monitors
    ii
    Document no. M1031518-02                                                                    
    2.2.20 Memory   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
    2.2.21 Recorder   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
    2.2.22 Network Option  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
    2.2.23 Wireless Network Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
    2.2.24 Interface Module, E-INT, M-INT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
    2.2.25 Device Interfacing Solution, N-DISxxx  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
    2.2.26 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
    Appendix A: Planned maintenance check form, S/5 Compact Monitors  A-1 
    						
    							Planned maintenance instructions
    1
                                              Document no. M1031518-02
    1 Planned maintenance instructions
    1.1 Introduction
    These instructions include procedures for planned maintenance (PM) for the Datex-Ohmeda S/5 
    Compact Anesthesia Monitor and S/5 Compact Critical Care Monitor. The Planned maintenance 
    should be performed once a year.
    These instructions include “Planned maintenance check form, S/5 Compact Monitors” to be filled in 
    when performing the corresponding procedures.
    The symbol 
     in the instructions means that the procedure performed should be signed in the 
    check form.
    The procedures should be performed in ascending order, bypassing those that are not applicable for 
    a particular monitor. 
    If you need further information on how to perform a certain Planned maintenance procedure, please 
    refer to the corresponding slot in the Technical Reference Manual.
    All menu selections related to the Datex-Ohmeda monitors are written in the following typeface:
    e.g. Parameters - Gas Unit
    As you enter the service menus, you need following passwords:
    Monitor Setup - Install/Service (password 16-4-34) - Service (password 26-23-8)
    In case you evaluate the measurement accuracy with a patient simulator, add the simulator’s 
    accuracy specification to the one for the monitor.
    1.2 Recommended tools
    For product(s) Tool Order No.
    All Airway modulesFlowmeter
    Compact Airway Module, E-CAiO(VX)/ 
    M-CAiO(VX)Calibration gas and regulator 755583/755534*
    Compact Airway Module, E-COVX/ M-COVX Calibration gas and regulator 755587/755534*
    Compact Airway Module, E-CO(V), M-C, 
    M-CO(V)Calibration gas and regulator 755581/755534*
    E-miniC/ M-miniC Calibration gas and regulator 755580/755534*
    Compact Airway Module, E-COVX, E-CAiOVX, 
    M-COVX, M-CAiOVXSampling line, 2 m 73318
    All Airway modules w/ (V) Spirometry tube, 2 m 890031
    All Airway modules w/ (V) D-lite 733950
    All Airway modules Sampling line, 6 m/19.7 ft 73306
    Hemodynamic modules
    Hemodynamic modules w/ (P), 
    M-NIBPNIBP cuff and hose 2753E (cuff)
    877235 (hose) 
    						
    							Datex-Ohmeda S/5 Compact Anesthesia and Compact Critical Care Monitors
    2
    Document no. M1031518-02                                                                           
    Hemodynamic modules w/ (P) InvBP transducer 70077-001
    Multi-Link ECG accessories, IEC
    E-PSM(P)/ E-PRESTN/ M-PRESTN - Multi-link 3-leadwire set 412682-003
    - Multi-link 5-leadwire set 412681-003
    - Multi-link 5-leadwire set, C2-C6 416467-004
    E-PRESTN/ M-PRESTN w/ (E12) - Multi-link 12-lead ECG trunk cable 416035-002
    or Multi-Link ECG accessories, AHA 
    E-PSM(P)/ E-PRESTN/ M-PRESTN - Multi-link 3-leadwire set 412682-001
    - Multi-link 5-leadwire set 4162681-001
    - Multi-link 5-leadwire set, V2-V6 416467-003
    E-PRESTN/ M-PRESTN w/ (E12) - Multi-link 12-lead ECG trunk cable 416035-001
    M-NESTPR 3-lead ECG trunk cable 545302
    M-NESTPR 5-lead ECG cable 545303
    M-NE12STPR 10-leadwire ECG cable 545324
    E-PSM(P)/ E-PRESTN SpO
    2 finger probe OXY-F-UN
    SpO
    2 Interconnect Cable OXY-ES3
    M-PRESTN SpO
    2 finger probe OXY-F4-N or SAS-F4
    E-NSAT/ M-NSAT Nellcor SpO
    2 probe
    Hemodynamic modules w/ (T) Temperature test set 884515
    Hemodynamic E-Modules w/ (NIBP) Adult NIBP cuff hose with cuff ID 2021285-001
    Infant cuff hose without cuff ID 414874-001
    Hemodynamic M-Modules w/ (NIBP) Adult NIBP cuff 572435
    Adult NIBP cuff hose 877235
    E-COP, E-COPSv, M-COP, M-COPSv C.O. Catheter cable 16590
    E-COPSv/ M-COPSv SvO
    2 simulator 890121
    Tonometry Module, E-TONO/ M-TONO Calibration gas and regulator 755580/755534
    Sampling line 733251
    Luer plug
    Pressure manometer
    Tonometrics
    TM catheterTONO-14F or another 
    suitable TONO-_F catheter
    EEG Module, E-EEG/ M-EEG Earphones
    EEG simulator 90502 For product(s) Tool Order No. 
    						
    							Planned maintenance instructions
    3
                                              Document no. M1031518-02
    NOTE: * Ensure that the calibration gas and regulator are functioning properly before calibration. 
    Perform annual maintenance on the regulator as required. For more information see section 
    “Adjustments and calibrations” in Compact Airway modules slot.
    1.2.1 Hemodynamic patient simulators
    The following tables present the patient simulators’ compatibility with each hemodynamic module, and the 
    accessories needed:
    Table 1 Patient simulators’ compatibility with each hemodynamic module BIS Module, E-BIS/ M-BIS BIS simulator or
    BIS Sensor simulator900509
    900508
    E-ENTROPY/ M-ENTROPY Simulator for M-ENTROPY N-ES
    Entropy sensor cable 8002964
    E-NMT/ M-NMT NMT simulator 871251
    NMT ElectroSensor 888416
    NMT sensor cable 888415
    MemCard – Menu 893860 (English)
    MemCard – Data 887045 (English)
    All M-Modules Screwdrivers
    All E-Modules Torx screwdrivers; T8, T10
    Module ParameterPatient simulator
    M1010831 MedSim 874027
    E-PSM(P),E-PRESTN ECG Ok Multilink ECG acc. Not compatible
    T402015-004 402015-004 and
    M1010832
    InvBP OkM1010858 For product(s) Tool Order No.
    ECG 
    						
    							Datex-Ohmeda S/5 Compact Anesthesia and Compact Critical Care Monitors
    4
    Document no. M1031518-02                                                                           
    Table 2 Adapter cables for hemodynamic patient simulators
    1.3 Recommended parts
    M-PRESTN ECG Ok Multilink ECG acc. Not compatible
    TOkM1010832 M1010832
    InvBP Not compatible Ok Ok
    M-NESTPR ECG Not compatible 300 series acc. Ok
    12 lead ECG Not compatible 300 series acc. Not compatible
    TOkM1010832 M1010832
    InvBP Not compatible Ok Ok
    Patient simulator Adapter cables for simulators
    Hemodynamic patient simulator Dual temperature adapter cable 402015-004
    Hemodynamic patient simulator Dual Inv.BP adapter cable 2005772-001
    Medsim Temperature adapter cable M1010832
    Medsim Inv.BP adapter cable M1010858
    Lionheart & MPS450 Temperature adapter cable M1010846
    Lionheart & MPS450 Inv.BP adapter cable M1010862
    For product(s) Part Order No.
    CM(C) Frame Unit Fan filter 896085
    CM(C) Display Unit Fan filter 874594
    Central Processing Board Battery for SRAM/Timekeeper  197230
    Recorder paper 74205
    Tonometry Module, E-TONO/ M-TONO 733382 Module ParameterPatient simulator
    M1010831 MedSim 874027
    NIBP
    ECGSpO
    T1
    T2P1
    P2
    2
    Auto
    On/OffStart
    CancelZero
    P1Zero
    P2
    T2
    P1
    P2T1
    NIBP
    ECG+
    RespSpO2 
    						
    All GE manuals Comments (0)

    Related Manuals for GE S5 Service Manual