Home > Honeywell > Scanner > Honeywell 1900ghd-2 User Manual

Honeywell 1900ghd-2 User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Honeywell 1900ghd-2 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 178 Honeywell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							 ix
    Maintenance ...................................................................................................................... 14-1
    Cleaning the Scanner .................................................................................................. 14-1
    Cleaning the Window ................................................................................................... 14-1
    Health Care Housing ................................................................................................... 14-1
    Inspecting Cords and Connectors ............................................................................... 14-2
    Replacing Cables in Corded Scanners.............................................................................. 14-2
    Replacing a Xenon Interface Cable ............................................................................. 14-2
    Replacing a Granit Interface Cable.............................................................................. 14-2
    Replacing Cables and Batteries in Cordless Systems ...................................................... 14-2
    Replacing an Interface Cable in a Base ...................................................................... 14-2
    Changing a Xenon Scanner Battery ............................................................................ 14-3
    Changing a Granit Scanner Battery ............................................................................. 14-3
    Troubleshooting a Corded Scanner................................................................................... 14-3
    Troubleshooting a Cordless System.................................................................................. 14-4
    Troubleshooting a Base ............................................................................................... 14-4
    Troubleshooting a Cordless Scanner .......................................................................... 14-4
    Chapter 15 - Customer Support
    Technical Assistance ......................................................................................................... 15-1
    Product Service and Repair............................................................................................... 15-1
    Chapter A - Reference Charts
    Symbology Charts ...............................................................................................................A-1
    Linear Symbologies .......................................................................................................A-1
    2D Symbologies.............................................................................................................A-2
    Postal Symbologies .......................................................................................................A-2
    ASCII Conversion Chart (Code Page 1252) ........................................................................A-3
    Lower ASCII Reference Table .............................................................................................A-4
    ISO 2022/ISO 646 Character Replacements ......................................................................A-7
    Keyboard Key References.................................................................................................A-10
    Sample Symbols
    Programming Chart 
    						
    							1 - 1
    1
    Getting Started
    About This Manual
    This User’s Guide provides installation and programming instructions for the Xenon™ 1900 and 1910 corded area-imaging 
    scanners, the Xenon 1902 and 1912 cordless area-imaging scanners, the Granit 1910i and 1980i corded industrial scanners, 
    and the Granit 1911i and 1981i cordless industrial scanners.  Product specifications, dimensions, warranty, and customer sup-
    port information are also included.
    Honeywell bar code scanners are factory programmed for the most common terminal and communications settings.  If you need 
    to change these settings, programming is accomplished by scanning the bar codes in this guide.
    An asterisk (*) next to an option indicates the default setting.
    Unpacking Your Device
    After you open the shipping carton containing the product, take the following steps:
     Check for damage during shipment.  Report damage immediately to the carrier who delivered the carton.
     Make sure the items in the carton match your order.
     Save the shipping container for later storage or shipping.
    Connecting the Device
    Connecting with USB
    A scanner or a cordless base can be connected to the USB port of a computer. 
    1. Connect the appropriate interface cable to the device first, then to the computer.
    Corded Xenon Scanner 
    USB Connection: 
    						
    							1 - 2
    2. If you are connecting a Granit scanner, make sure the cable is pushed tightly into the scanner.  Loosen the locking plate 
    and slide it over the base of the cable connector to lock the cable in place.  Tighten the screw.
    Corded Granit Scanner 
    USB Connection:
    CCB01-010BT Base 
    USB Connection: 
    						
    							1 - 3
    Note: The power supply must be ordered separately, if needed.
    3. If you are connecting a CCB01-010BT Base, make sure the cables are secured in the wireways in the bottom of the 
    cordless base and the base sits flat on a horizontal surface.  If you are connecting a CCB02-100BT or CCB05-100BT 
    Base, see Mounting a CCB02-100BT/CCB05-100BT Baseon page 1-9.
    4. The scanner beeps.
    5. Verify the scanner or cordless base operation by scanning a bar code from the Sample Symbols in the back of this 
    manual.
    The unit defaults to a USB PC Keyboard.  Refer to page 2-3 for other USB terminal settings.
    For additional USB programming and technical information, refer to “USB Application Note,” available at www.honey-
    wellaidc.com.
    Connecting with Keyboard Wedge
    A scanner or cordless base can be connected between the keyboard and PC as a “keyboard wedge,” where the scanner 
    provides data output that is similar to keyboard entries.  
    Note: The Granit 1980i does not support the keyboard wedge interface.
    The following is an example of a keyboard wedge connection:
    1. Turn off power and disconnect the keyboard cable from the back of the terminal/computer.
    CCB02-100BT/CCB05-
    100BT Base USB 
    Connection: 
    						
    							1 - 4
    2. Connect the appropriate interface cable to the device and to the terminal/computer.
    3. If you are connecting a Granit scanner, make sure the cable is pushed tightly into the scanner.  Loosen the locking plate 
    and slide it over the base of the cable connector to lock the cable in place.  Tighten the screw.
    Corded Xenon Scanner 
    Keyboard Wedge 
    Connection:
    Corded Granit Scanner 
    Keyboard Wedge 
    Connection: 
    						
    							1 - 5
    Note: The power supply must be ordered separately, if needed.
    4. If you are connecting a CCB01-010BT Base, make sure the cables are secured in the wireways in the bottom of the 
    cordless base and the base sits flat on a horizontal surface.  If you are connecting a CCB02-100BT or CCB05-100BT 
    Base, see Mounting a CCB02-100BT/CCB05-100BT Baseon page 1-9.
    5. Turn the terminal/computer power back on.  The scanner beeps.
    6. Verify the scanner or cordless base operation by scanning a bar code from the Sample Symbols in the back of this 
    manual.  The scanner beeps once. If using a Granit scanner, it also vibrates. 
    The unit defaults to an IBM PC AT and compatibles keyboard wedge interface with a USA keyboard.  A carriage return (CR) 
    suffix is added to bar code data. 
    CCB01-010BT Base Keyboard 
    Wedge Connection:
    CCB02-100BT/CCB05-100BT  
    Base Keyboard Wedge 
    Connection: 
    						
    							1 - 6
    Connecting with RS232 Serial Port
    1. Turn off power to the terminal/computer.
    2. Connect the appropriate interface cable to the scanner.
    Note: For the scanner or cordless base to work properly, you must have the correct cable for your type of terminal/computer.
    Corded Xenon Scanner 
    RS232 Serial Port 
    Connection:
    Corded Granit Scanner RS232 Serial 
    Port Connection: 
    						
    							1 - 7
    3. If you are connecting a Granit scanner, make sure the cable is pushed tightly into the scanner.  Loosen the locking plate 
    and slide it over the base of the cable connector to lock the cable in place.  Tighten the screw.
    Note: The power supply must be ordered separately, if needed.
    4. If you are connecting a CCB01-010BT Base, make sure the cables are secured in the wireways in the bottom of the 
    cordless base and the base sits flat on a horizontal surface.  If you are connecting a CCB02-100BT or CCB05-100BT 
    Base, see Mounting a CCB02-100BT/CCB05-100BT Baseon page 1-9.
    5. Plug the serial connector into the serial port on your computer.  Tighten the two screws to secure the connector to the 
    port.
    6. Once the scanner or cordless base has been fully connected, power up the computer.
    This interface programs 115,200 baud, 8 data bits, no parity, and 1 stop bit. 
      
    CCB01-010BT Base 
    RS232 Serial Port  Connection:
    CCB02-100BT/CCB05/100BT Base 
    RS232 Serial Port Connection: 
    						
    							1 - 8
    Connecting with RS485
    A Xenon scanner or cordless base can be connected for an IBM POS terminal interface.  (This interface is not available in 
    the Granit devices.)
    1. Connect the appropriate interface cable to the device, then to the computer.
    Note: The power supply must be ordered separately, if needed.
    2. Make sure the cables are secured in the wireways in the bottom of the cordless base and the base sits flat on a 
    horizontal surface.
    3. Turn the terminal/computer power back on.  The scanner beeps.
    4. Verify the scanner or cordless base operation by scanning a bar code from the Sample Symbols in the back of this 
    manual.  The scanner beeps once.  If using a Granit scanner, it also vibrates.
    For further RS485 settings, refer to RS485, page 2-2.
    Corded Xenon Scanner 
    RS485 Connection:
    CCB01-010BT Base 
    RS485 Connection: 
    						
    All Honeywell manuals Comments (0)