    Mounting a CCB01-010BT Charge Base
    Mounting a CCB02-100BT/CCB05-100BT Base
    The CCB02-100BT or CCB05-100BT Base can be mounted on either a horizontal or vertical surface.  The cables can be routed 
    through either the top or the bottom of the base. 
    The cables can be routed down through the bottom of the base, securing the cables in the wireways.
    The cables can also be routed up through the top of the base, crossing them over and securing the cables in the wireways.  
    When routing the cables up through the top of the base, be sure to cross the cables over before placing in the wireways.  If not, 
    too much strain is placed on the cable connectors.
    8x32 thread 
    x .39 in. (10mm) deep 2.36 in.
    59.84mm
    3.35 in.
    85.09mm2.8 in.
    72.1mm 
    						
    							1 - 10
    When mounted on a vertical surface, a locking system is used to secure the scanner when it is in the stand.  When mounted on 
    a horizontal surface, the locking mechanism should be set to unlocked (pushed up).  When mounted on a vertical surface, the 
    locking mechanism should be set to locked (pushed down).
    Use 30mm screws, appropriate for the mounting surface material, to mount the base securely.
     
    Locked position 
    for vertical mountUnlocked position 
    for horizontal mount
    2 in.
    51.17mm5.31 in.
    134.92mm2.51 in.
    63.7mm
    2.36 in.
    60mm
    .84 in.
    21.42mm 
    						
    							1 - 11
    Reading Techniques
    Xenon 1900/1902/1910/1912 and Granit 1910i/1911i
    The Xenon 1900/1902 scanners have a view finder that projects a bright red aiming beam that corresponds to the scan-
    ner’s horizontal field of view.  The Xenon 1910/1912 and Granit 1910i/1911i scanners have an aiming pattern.  The aiming 
    beam or pattern should be centered over the bar code, but it can be positioned in any direction for a good read.
    Linear bar codes 
    with aiming beam
    2D Matrix symbol 
    with aiming beamLinear bar codes 
    with aiming pattern
    2D Matrix symbol 
    with aiming pattern 
    						
    							1 - 12
    Granit 1980i/1981i
    The Granit 1980i/1981i scanners use a laser aimer (red dot) and a red LED (red box) to locate bar codes.  Use the red LED 
    when scanning at a near distance (less than 11.8 inches / 30 cm) and center the box over the bar code.  The laser aimer 
    (red dot) appears to the right of the center of the bar code. Use the laser aimer (red dot) when scanning at a far distance 
    (up to 50 feet / 15.2 meters) and aim at the center of the bar code.  At far distances the red box may not be apparent.  For 
    both near distance and far distance, the aimers can be positioned in any direction for a good read. 
    The aiming beam or pattern is smaller when the scanner is closer to the code and larger when it is farther from the code.  
    Symbologies with smaller bars or elements (mil size) should be read closer to the unit.  Symbologies with larger bars or ele-
    ments (mil size) should be read farther from the unit.   To read single or multiple symbols (on a page or on an object), hold 
    the scanner at an appropriate distance from the target, pull the trigger, and center the aiming beam or pattern on the sym-
    bol.  If the code being scanned is highly reflective (e.g., laminated), it may be necessary to tilt the code up 15° to 18° to pre-
    vent unwanted reflection.
    Menu Bar Code Security Settings
    Honeywell scanners are programmed by scanning menu bar codes or by sending serial commands to the scanner.  If you want 
    to restrict the ability to scan menu codes, you can use the Menu Bar Code Security settings.  Please contact the nearest techni-
    cal support office (see Technical Assistance on page 15-1) for further information.
    Near distance scanning
    less than 11.8 in/30 cmFar distance scanning
    up to 50 ft/15.2 m 
    						
    							1 - 13
    Setting Custom Defaults
    You have the ability to create a set of menu commands as your own, custom defaults.  To do so, scan the Set Custom Defaults 
    bar code below before scanning the menu commands for your custom defaults.  If a menu command requires scanning numeric 
    codes from the back cover, then a Save code, that entire sequence will be saved to your custom defaults.  When you have 
    entered all the commands you want to save for your custom defaults, scan the Save Custom Defaults bar code.
    Note: When using a cordless system, the Custom Defaults settings apply to all workgroups.  Scanning the Save Defaults bar 
    code also causes both the scanner and the base or Access Point to perform a reset and become unlinked.  The scanner 
    must be placed in its base to re-establish the link before any setup codes are entered.  If using an Access Point, the linking 
    bar code must be scanned.  See Cordless System Operationbeginning on page 3-1 for additional information.
    You may have a series of custom settings and want to correct a single setting.  To do so, just scan the new setting to overwrite 
    the old one.  For example, if you had previously saved the setting for Beeper Volume at Low to your custom defaults, and decide 
    you want the beeper volume set to High, just scan the Set Custom Defaults bar code, then scan the Beeper Volume High 
    menu code, and then Save Custom Defaults.  The rest of the custom defaults will remain, but the beeper volume setting will be 
    updated.
    Resetting the Custom Defaults
    If you want the custom default settings restored to your scanner, scan the Activate Custom Defaults bar code below.  This is 
    the recommended default bar code for most users.  It resets the scanner to the custom default settings.  If there are no custom 
    defaults, it will reset the scanner to the factory default settings.  Any settings that have not been specified through the custom 
    defaults will be defaulted to the factory default settings.
    Note: If using a cordless system, scanning this bar code also causes both the scanner and the base or Access Point to perform 
    a reset and become unlinked.  The scanner must be placed in its base to re-establish the link.  If using an Access Point, 
    the linking bar code must be scanned.  See Cordless System Operationbeginning on page 3-1 for additional information.
    Set Custom Defaults
    Save Custom Defaults
    Activate Custom Defaults 
    						
    							2 - 1
    2
    Programming the Interface
    Introduction
    This chapter describes how to program your system for the desired interface.
    Programming the Interface - Plug and Play
    Plug and Play bar codes provide instant scanner set up for commonly used interfaces.
    Note: After you scan one of the codes, power cycle the host terminal to have the interface in effect.
    Keyboard Wedge
    If you want your system programmed for an IBM PC AT and compatibles keyboard wedge interface with a USA keyboard, scan 
    the bar code below.  Keyboard wedge is the default interface.
    Note: The Granit 1980i does not support the keyboard wedge interface.
    Note: The following bar code also programs a carriage return (CR) suffix.
    Laptop Direct Connect
    For most laptops, scanning the Laptop Direct Connect bar code allows operation of the scanner in parallel with the integral 
    keyboard.  The following Laptop Direct Connect bar code also programs a carriage return (CR) suffix and turns on Emulate 
    External Keyboard (page 2-16).
    Note: The Granit 1980i does not support Laptop Direct Connect.
    RS232 Serial Port
    The RS232 Interface bar code is used when connecting to the serial port of a PC or terminal.  The following RS232 Interface 
    bar code also programs a carriage return (CR) and a line feed (LF) suffix, baud rate, and data format as indicated below.  It also 
    changes the trigger mode to manual.
    OptionSetting
    Baud Rate 115,200 bps
    Data Format 8 data bits, no parity bit, 1 stop bit
    IBM PC AT and Compatibles with 
    CR suffix
    Laptop Direct Connect
    with CR suffix
    RS232 Interface 
    						
    							2 - 2
    RS485
    Scan one of the following “Plug and Play” codes to program the scanner for an IBM POS terminal interface.
    Note: This interface is not supported in Granit devices.
    After scanning one of these codes, you must power cycle the cash register.
    Each bar code above also programs the following suffixes for each symbology:
    * Suffixes programmed for Code 128 with IBM 4683 Port 5B, IBM 4683 Port 9B HHBCR-1, and IBM 4683 Port 17 Interfaces
    **Suffixes programmed for Code 128 with IBM 4683 Port 9 HHBCR-2 Interface
    RS485 Packet Mode
    The following selection allows you to break up large bar code data into smaller packets on an IBM POS terminal.  To break 
    up large bar codes into small packets, scan the Packet Mode On bar code below.  Scan the Packet Mode Off bar code if you 
    want large bar code data to be sent to the host in a single chunk.  Default = Packet Mode Off.
    SymbologySuffixSymbologySuffix
    EAN 8 0C Code 39 00  0A  0B
    EAN 13 16 Interleaved 2 of 5 00  0D  0B
    UPC A 0D Code 128 * 00  0A  0B
    UPC E 0A Code 128 ** 00  18  0B
    MaxiCode 00  2F  0B
    IBM Port 5B Interface
    IBM Port 9B 
    HHBCR-1 Interface
    IBM Port 17 Interface
    IBM Port 9B
    HHBCR-2 Interface
    * Packet Mode Off
    Packet Mode On 
    						
    							2 - 3
    RS485 Packet Length
    If you are using Packet mode, you can specify the size of the data “packet” that is sent to the host.  Scan the Packet 
    Length bar code, then then the packet size (from 20 - 256) from the Programming Chart inside the back cover of this 
    manual, then Save.  Default = 40.
    USB IBM SurePos
    Scan one of the following “Plug and Play” codes to program the scanner for an IBM SurePos (USB handheld scanner) or IBM 
    SurePos (USB tabletop scanner) interface.
    Note: After scanning one of these codes, you must power cycle the cash register.
    Each bar code above also programs the following suffixes for each symbology:
    USB PC or Macintosh Keyboard
    Scan one of the following codes to program the scanner for USB PC Keyboard or USB Macintosh Keyboard.  Scanning these 
    codes also adds a CR suffix.
    SymbologySuffixSymbologySuffix
    EAN 8 0C Code 39 00  0A  0B
    EAN 13 16 Interleaved 2 of 5 00  0D  0B
    UPC A 0D Code 128 00  18  0B
    UPC E 0A Code 39 00  0A  0B
    Packet Length
    USB IBM SurePos 
    (USB Handheld Scanner) 
    Interface
    USB IBM SurePos 
    (USB Tabletop Scanner) 
    Interface
    U
    SB
     
    K
    e
    yb
    o
    a
    r
    d 
    (
    P
    C
    )
    USB Keyboard (Mac)
    USB Japanese Keyboard (PC) 
    						
    							2 - 4
    USB HID
    Scan the following code to program the scanner for USB HID bar code scanners.
    USB Serial
    Scan the following code to program the scanner to emulate a regular RS232-based COM Port.  If you are using a Microsoft® 
    Windows® PC, you will need to download a driver from the Honeywell website (www.honeywellaidc.com).  The driver will use 
    the next available COM Port number.  Apple® Macintosh computers recognize the scanner as a USB CDC class device and 
    automatically use a class driver.  
    Note: No extra configuration (e.g., baud rate) is necessary.
    CTS/RTS Emulation
    ACK/NAK Mode
    Remote MasterMind™ for USB
    When using a USB interface, you may wish to configure your scanner to communicate with Remote MasterMind Scanner Man-
    agement Software (ReM).  Scan the ReM On bar code to communicate with ReM.  To disable this capability, scan ReM Off. 
    USB HID Bar Code Scanner
    USB Serial
    CTS/RTS Emulation On
    * CTS/RTS Emulation Off
    ACK/NAK Mode On
    * ACK/NAK Mode Off
    ReM Off 
    						