    							2.10 [4] Extension
    PC Programming Manual 281
    Default
    Current slot number
    Value Range
    Slot number
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    None
    Por t
    Indicates the por t number (reference only).
    Default
    Current port number
    Value Range
    Port number
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    2.7.4 [1-1] Slot—Extension Port
    Feature Manual References
    None
    Extension Number
    Specifies the extension number of the extension.
    To change the extension number of a wired extension, follow the steps below:
    1.Type the new extension number, then click Apply.
    2.Set the status of the extension port to OUS, then INS.
    When changing the extension number, make sure that the extension port is not in use. If the extension 
    number is changed while the por t is in use, the new extension number will not come into effect.
    Note that extensions that will have a mailbox using a VM in DPT integration must have extension 
    numbers of 2–4 digits. 
    						
    							2.10 [4] Extension
    282 PC Programming Manual
    Default
    Starting at 101
    (For port 01 of the first extension card that is installed. Extension numbers are preset for subsequent 
    extensions by adding one to the previous extension number.)
    Value Range
    Max. 5 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    2.7.5 [1-1] Slot—Extension Port—Port Command
    Feature Manual References
    None
    Extension Name
    Specifies the name of the extension.
    Default
    Not stored.
    Value Range
    Max. 20 characters
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    None
    Forced Automatic Answer
    Specifies whether the extension automatically answers all incoming calls (both intercom and CO line 
    calls) without going off-hook, regardless of the Hands-free Answerback setting.
    Default
    Off
    Value Range
    Off, On 
    						
    							2.10 [4] Extension
    PC Programming Manual 283
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    None
    Flexible Button Programming Mode
    Specifies whether the extension user can modify all flexible CO buttons without limitation, or only the 
    One-touch Dialing buttons. When the mode is set to One-touch Dial, there is no need to enter 2 
    before the number when customizing a One-touch Dialing button.
    Default
    No Limitation
    Value Range
    No Limitation, One-touch Dial
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    None
    Display Lock / SVM Lock
    Locks or unlocks the Incoming Call Log and Simplified Voice Message Log display (i.e., specifies 
    whether other extension users can see the Incoming Call Log and SVM Log information at the 
    extension).
    Default
    Unlock
    Value Range
    Unlock, Lock
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    2.10.7 [4-1-6] Wired Extension—Simplified Voice Message 
    						
    							2.10 [4] Extension
    284 PC Programming Manual
    Feature Manual References
    1.3.3 Call Log, Incoming
    1.16.5 SVM (Simplified Voice Message)
    Paging Deny
    Specifies whether paging of the extension from other extensions is enabled.
    Default
    Disable
    Value Range
    Disable, Enable
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    1.13.1 Paging
    Option 7
    Slot
    Indicates the slot position of each extension card (reference only).
    Default
    Current slot number
    Value Range
    Slot number
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    None
    Por t
    Indicates the port number (reference only). 
    						
    							2.10 [4] Extension
    PC Programming Manual 285
    Default
    Current port number
    Value Range
    Port number
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    2.7.4 [1-1] Slot—Extension Port
    Feature Manual References
    None
    Extension Number
    Specifies the extension number of the extension.
    To change the extension number of a wired extension, follow the steps below:
    1.Type the new extension number, then click Apply.
    2.Set the status of the extension port to OUS, then INS.
    When changing the extension number, make sure that the extension port is not in use. If the extension 
    number is changed while the por t is in use, the new extension number will not come into effect.
    Note that extensions that will have a mailbox using a VM in DPT integration must have extension 
    numbers of 2–4 digits.
    Default
    Starting at 101
    (For port 01 of the first extension card that is installed. Extension numbers are preset for subsequent 
    extensions by adding one to the previous extension number.)
    Value Range
    Max. 5 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    2.7.5 [1-1] Slot—Extension Port—Port Command
    Feature Manual References
    None
    Extension Name
    Specifies the name of the extension. 
    						
    							2.10 [4] Extension
    286 PC Programming Manual
    Default
    Not stored.
    Value Range
    Max. 20 characters
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    None
    Flash Mode during CO Conversation
    Selects the function of the FLASH/RECALL button during a CO line conversation.
    Default
    Flash Recall
    Value Range
    EFA, Terminate, Flash Recall
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    1.5.1 EFA (External Feature Access)
    1.6.2 Flash/Recall/Terminate
    Incoming Call Log Memory
    Specifies the number of incoming CO line calls that are retained in the extensions Incoming Call Log 
    memory.
    Default
    10
    Value Range
    0–100 
    						
    							2.10 [4] Extension
    PC Programming Manual 287
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    1.3.3 Call Log, Incoming
    Option 8
    Slot
    Indicates the slot position of each extension card (reference only).
    Default
    Current slot number
    Value Range
    Slot number
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    None
    Por t
    Indicates the por t number (reference only).
    Default
    Current port number
    Value Range
    Port number
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    2.7.4 [1-1] Slot—Extension Port 
    						
    							2.10 [4] Extension
    288 PC Programming Manual
    Feature Manual References
    None
    Extension Number
    Specifies the extension number of the extension.
    To change the extension number of a wired extension, follow the steps below:
    1.Type the new extension number, then click Apply.
    2.Set the status of the extension port to OUS, then INS.
    When changing the extension number, make sure that the extension port is not in use. If the extension 
    number is changed while the port is in use, the new extension number will not come into effect.
    Note that extensions that will have a mailbox using a VM in DPT integration must have extension 
    numbers of 2–4 digits.
    Default
    Starting at 101
    (For port 01 of the first extension card that is installed. Extension numbers are preset for subsequent 
    extensions by adding one to the previous extension number.)
    Value Range
    Max. 5 digits (consisting of 0–9)
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    2.7.5 [1-1] Slot—Extension Port—Port Command
    Feature Manual References
    None
    Extension Name
    Specifies the name of the extension.
    Default
    Not stored.
    Value Range
    Max. 20 characters
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    None 
    						
    							2.10 [4] Extension
    PC Programming Manual 289
    Feature Manual References
    None
    Group CW w/o Tone (Ring after Call)
    Enables an incoming call to an incoming call distribution group to arrive at a previously busy extension 
    at the moment that the extension goes on-hook for the previous call.
    Default
    Enable
    Value Range
    Disable, Enable
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    None
    Extension Caller ID
    Enables the extension to send Caller ID information to an SLT.
    Note that the setting of this parameter is only effective when a resource for sending extension Caller 
    ID is assigned in Extension Caller ID Resource-1, 2 for the port in 2.8.18 [2-10] Extension CID 
    Settings.
    Default
    Enable
    Value Range
    Disable, Enable
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    2.8.18 [2-10] Extension CID Settings—Extension Caller ID Resource-1, 2
    Feature Manual References
    1.3.1 Caller ID 
    						
    							2.10 [4] Extension
    290 PC Programming Manual
    Incoming Call Wait Timer for Extension Caller ID
    Specifies the length of time that the ringing for a call is delayed when the call follows immediately after 
    the previous unanswered call. When receiving two calls in quick succession (e.g., when a call waiting 
    in a queue is directed to an extension immediately after the previous unanswered call stops ringing), 
    some SLTs require a pause, after the first call stops ringing, to receive the second calls Caller ID 
    information.
    Note that the setting of this parameter is only effective when a resource for sending extension Caller 
    ID is assigned in Extension Caller ID Resource-1, 2 for the port in 2.8.18 [2-10] Extension CID 
    Settings.
    Default
    0
    Value Range
    0–15 s
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    2.8.18 [2-10] Extension CID Settings—Extension Caller ID Resource-1, 2
    Feature Manual References
    1.3.1 Caller ID
    Wrap-up Timer
    Specifies the length of time that must pass after completing a call before an extension will accept 
    another call when logged in as a member of an Incoming Call Distribution Group.
    Default
    0 s
    Value Range
    0–3000 s
    Maintenance Console Location
    2.10.1 [4-1-1] Wired Extension—Extension Settings
    Programming Manual References
    None
    Feature Manual References
    1.9.3 ICD Group Features—Log-in/Log-out 
    						