Panasonic Projector Pt Ez570u Operating Instructions
Have a look at the manual Panasonic Projector Pt Ez570u Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

Network ENGLISH - 81 Settings Network config page J You can change network settings on projector when connecting with the administrator authority. LAN settings z Click [Detailed set up] in the menu.1 ) Click [Change] to change the LAN settings.2 ) zTo return to the previous window, click [Back]. Complete the detailed settings and 3 ) click [Next]. When [Next] is clicked, the next page appears, enabling z you to complete the detailed settings as desired. Settings performed here are the same as the settings performed with the [Network] menu of the projector. Click [Submit].4 ) zThe settings will be registered. Note Changing the setting of LAN while connected with LAN might disconnect the connection. z

Network 82 - ENGLISH Settings Ping test page J This page makes it possible to check whether the network is connected to the e-mail server, POP server, DNS server, etc. Click [Detailed set up], then [Ping test] to display the Ping test page. Display which appears when the connection was successful. Display which appears when the connection failed. 1 Enter the IP address of the server to be tested. 2 Button for conducting the test. 2 1 ECO management set up page J This page makes it possible to set the savings of power consumption. Click [Detailed set up], then [Eco management set up] to display the ECO management set up page. Click [Submit] to execute the items you have set. 1 Set the brightness of the screen. 2 Set the conditions of the AUTO POWER SAVE. 3 Set the time of the countdown when no signal input. 1 2 3

Network ENGLISH - 83 Settings E-mail set up page J With this projector, if a problem occurs or if the lamp usage time reaches a set value, an e-mail message can be sent to one or more preset e-mail addresses (maximum two addresses). Click [Detailed set up], then [E-mail set up] to display the E-mail setup page. 1 Select Enable to use the e-mail function. 2 Enter the IP address or server name of the e-mail server (SMTP). The DNS server must be set if the server name is entered. 3 Enter the e-mail address of the projector. (maximum 63 characters) 4 The user can enter the location of, for example, the installed projector so that the recipient may easily identify the originator of the e-mail. (maximum 63 characters) 5 The user can modify the minimum time interval of temperature warning mail. The default value is 60 minutes. In this case, the user cannot send another mail for 60 minutes after sending previous temperature warning mail even the set warning temperature is reached again. 6 Select the temperature of the intake sensor at which to send a warning message. 1 Enter the E-mail Address1 of your desired recipient. 2 Select the conditions for sending e-mail. MAIL CONTENTS:Select [NORMAL] or [SIMPLE]. ERROR:An error is detected by self-diagnosis. LAMP RUNTIME:Remaining lamp service time has reached the value set in the field. INTAKE AIR TEMPERATURE:Intake air temperature has reached the value set in the field. 6 5 4 3 2 1 2 1

Network 84 - ENGLISH Settings E-mail set up page (continued) J 1 Enter the E-mail Address2 of your desired recipient. 2 Select the conditions for sending e-mail. MAIL CONTENTS:Select [NORMAL] or [SIMPLE]. ERROR:An error is detected by self-diagnosis. LAMP RUNTIME:Remaining lamp service time has reached the value set in the field. INTAKE AIR TEMPERATURE:Intake air temperature has reached the value set in the field. Authentication set up page J The POP/SMTP server is set on this page when POP/SMTP authentication is required for mail transmissions. Click [Detailed set up], then [Authentication set up] to display the Authentication server setup page. 1 Select the authentication method specified by your Internet service provider. 2 Set this if SMTP authentication has been selected. 3 POP server name field Available input characters: Alphanumeric characters (A - Z, a - z, 0 - 9), hyphen (-), period (.) 4 POP/SMTP server user name field 5 POP/SMTP server password field 6 Enter the port number for the SMTP server (normally “25”). 7 Enter the port number for the POP server (normally “110”). 8 Button to update settings 2 1 1 2 3 4 5 6 7 8

Network ENGLISH - 85 Settings Contents of mail sent J Mail with the contents shown below is sent when the e-mail settings have z been established. === Panasonic projector report(CONFIGURE) ===Projector Ty pe : PT-EZ570Serial No : 000000000----- E-mail setup data -----TEMPER ATURE WARNING SETUP MINIMUM TIME at [ 60] minutes interval INTAKE AIR TEMPER ATURE Over [ 32degC / 89degF ] ERROR [ OFF ] LA MP RUNTIME [ OFF ] at REM AIN [ 400] H LA MP RUNTIME [ OFF ] at REM AIN [ 200] H INTAKE AIR TEMPER ATURE [ OFF ] ----- check system -----M AIN CPU BUS [ OK ]FAN [ OK ]INTAKE AIR TEMPER ATURE [ OK ]AROUND LA MP TEMPER ATURE [ OK ]OPTICS MODULE TEMPER ATURE [ OK ]LA MP REM AIN TIME [ OK ]LA MP STATUS [ OK ]APERTURS(CONTR AST-SHUTTER) [ OK ]SHUTTER [ OK ]AIR FILTER [ OK ]FILTER UNIT [ OK ] (Error code 00 00 00 00 00 00 00 00) Intake air temperature :[ 31 degC / 87 degF ]AROUND LA MP temperature :[ 37 degC / 98 degF ]Optics module temperature :[ 39 degC / 102 degF ] PROJECTOR RUNTIME 1 H LA MP ECO 500 HLA MP NOR M AL 300 HLA MP REM AIN 2400 H -------- Current status ---------M AIN VERSION 1.00NETWORK VERSION 1.00LA MP STATUS LA MP=ONINPUT RGBSIGNAL NA ME XGA6SIGNAL FREQUENCY 0.00kHz / 0.00Hz ----- Wired Network configuration -----DHCP Client OFF IP address 192.168.10.100M AC address 04:20:9A:00:00:00 ----- Memo -----

Network 86 - ENGLISH Settings Mail with the contents shown below is sent when an error has occurred. z === Panasonic projector report(ERROR) === Projector Ty pe : PT-EZ570 Serial No : 000000000 ----- check system ----- M AIN CPU BUS [ OK ] FAN [ OK ] INTAKE AIR TEMPER ATURE [ OK ] AROUND LA MP TEMPER ATURE [ OK ] OPTICS MODULE TEMPER ATURE [ OK ] LA MP REM AIN TIME [ OK ] LA MP STATUS [ FAILED ] APERTURS(CONTR AST-SHUTTER) [ OK ] SHUTTER [ OK ] AIR FILTER [ OK ] FILTER UNIT [ OK ] (Error code 00 40 00 00 00 00 00 08) Intake air temperature :[ 31 degC / 87 degF ] AROUND LA MP temperature :[ 37 degC / 98 degF ] Optics module temperature :[ 39 degC / 102 degF ] PROJECTOR RUNTIME 1 H LA MP ECO 500 H LA MP NOR M AL 300 H LA MP REM AIN 2400 H -------- Current status --------- M AIN VERSION 1.00 NETWORK VERSION 1.00 LA MP STATUS LA MP=OFF INPUT NETWORK ----- Wired Network configuration ----- DHCP Client OFF IP address 192.168.10.100 M AC address 04:20:9A:00:00:00 ----- Memo ----- Command port set up page J Set the port number to be used with command control. Click [Detailed set up] → [Command port set up]. 1 Input the port number to be used with command control 2 Setting update button 1 2

Network ENGLISH - 87 Settings Change Password page J Click [Change password]. 1 Administrator 2 User Administrator mode 1 Account 2 Current user name input field 3 Current password input field 4 New user name input field 5 New password input field 6 New password input field (re- enter for confirmation) 7 Button for executing password change User account 1 Account 2 New user name input field 3 New password input field 4 New password input field (re- enter for confirmation) 5 Button for executing password change User mode A user can change password only. 1 Current password input field 2 New password input field 3 New password input field (re- enter for confirmation) 4 Button for executing password change Note When changing the administrator account, both “Current user name” and “Current password” are required. z No account is not available . z Administrator account and user account should be differed. z 2 1 7 65 4 3 2 1 5 4 3 2 1 4 3 2 1

Network 88 - ENGLISH Settings CRSTRON RoomView page J You can monitor or control the projector using RoomView. To display the operation page of RoomView from Web Control screen, access with the administrator rights is required. (The [CRESTRON RoomView] button is not displayed on the Web Control screen for user rights.) When you click [CRESTRON RoomView], the RoomView operation page is displayed. If Adobe Flash Player is not installed in your computer, or if the browser does not support Flash, this page does not appear. In this case, return to the previous page by clicking [Back] in the operation page. Operation page 1 Logout, Tools, Info, Help Exit the page when the password has changed and switches the pages for tools, information, help using the tab. 2 POWER Switches between on and off of the power. 3 VOL DOWN, AV MUTE, VOL UP Sets the volume, AV mute. When the power of the projector is turned off, VOL DOWN, AV MUTE and VOL UP are not available. 4 Input Select Sets the input selection. When the power of the projector is turned off, this operation is not available. 5 Operation buttons on the menu screen Operates on the menu screen. 6 Freeze, image quality adjustment Sets freeze, image quality details. 7 Back Returns to the previous page. Tools page Click Tools on the operation page. 1 Control system Sets the information required for the communication with the controller that is connected to the projector. 2 User Password Sets the password for the user rights in the operation page of RoomView. 3 Admin Password Sets the password for the administrator rights in the operation page of RoomView. 4 Network status Displays the setting of wired LAN. DHCP: Displays the value in the current setting. IpAddres: Displays the value in the current setting. SubnetMask: Displays the value in the current setting. DefaultGateway: Displays the value in the current setting. DNSServer: Displays the value in the current setting. 5 Exit Return to the operation page. 1 2 3 4 5 6 7 1 2 3 4 5

Network ENGLISH - 89 Settings Info page Click Info on the operation page. 1 Projector name Displays the name of the projector. 2 Mac Address Displays the MAC address. 3 Resolution Displays the resolution of the projector. 4 Lamp Hours Displays the lamp usage time (converted value). 5 Power Status Displays the status of the power. 6 Source Displays the selected video input. 7 Projector Position Displays the projection method of the projector. 8 Lamp Mode Displays the lamp mode. 9 Error Status Displays the error status. 10 Exit Return the operation page. User mode A user can change password only. 1 Help Desk Sends or receive messages to the adminidtrator who uses Crestron RoomView. 1 2 4 3 5 6 7 8 9 10 1

90 - ENGLISH Maintenance About indicator status If an indicator turns on If a problem occurs within the projector, it will be notified with the temperature indicator , the filter indicator , the shutter indicator *, and the lamp indicator . Check the status of the indicators and take the following action. * (Only for EZ570 series, EW630 series and EX600 series.) CAUTION Before you take a remedial measure, follow the procedure of switching the power off indicated in “Turning off the projector”. z (Æpage 40) If multiple indicators light or blink, verify the status of the projecto\ r by looking at each indicator. z Note Confirm the status of the power indicated on the indicator. z When operating correctly J The status of the indicator is displayed with the following symbols. : Off, : On, : Flashing, : Off or On or Flashing Indicators Status of the projectorGreen/Red/Orange Red Orange Blue Orange //The power plug has been removed from the outlet. //*1*1*1*1 The projector is in the standby mode. Turns on when pressing the button on the remote control or the button on the side control. //*1*1*1*1The projector is operating normally. //*2*1*1*1*1 The lamp is cooling down. The projector does not turn on when pressing the button on the remote control or the button on the side control until the standby indicator changes to red. *2//*1*1*1*1The projector is in the power management mode. The lamp will turn on when controlling the projector, allowing the user to start operating it. //*2*1*1*1*1Power management mode is [On] and the lamp is cooling down. //*1*1*1The shutter function has been turned on. Press any button on the remote control or the side control to cancel the function. //*1*1*2*1The projector is in the shutter management mode. The lamp will turn on when controlling the projector, allowing the user to start operating it. //*2*1*1*2*1Shutter management mode is [On] and the lamp is cooling down. *1: The indicator will change according to different conditions, regardless of the status of other indicators. *2: The indicator will flash in approximately 1-second intervals.