    							Chapter 4 Settings — [PROJECTOR SETUP] menu
    ENGLISH - 101
    [ECO MANAGEMENT]
    Set the ECO management function to reduce the power consumption depending on the usage condition.
    Setting [AUTO POWER SAVE] 
    Enable/disable the [AMBIENT LIGHT DETECTION] and [NO SIGNAL LIGHTS-OUT] functions.
    1) 
    Press 
     as to select [ECO MANAGEMENT].
    2)
     
    Press the  button.
     fThe 
    
    [ECO MANAGEMENT] screen is displayed.
    3)
     
    Press 
     as to select [AUTO POWER SAVE].
    4)
     
    Press 
     qw to switch the item.
     fThe items will switch each time you press the button.
    [OFF] Disables the auto power save setting.
    [ON] Enables the auto power save setting.
    5) Press as to select [AMBIENT LIGHT DETECTION] or [NO SIGNAL LIGHTS-OUT].
    [AMBIENT LIGHT 
    DETECTION] Adjusts the power of the light source in accordance with the brightness \
    of the installed location.
    [NO SIGNAL LIGHTS-OUT] Automatically turns off the light source of the projector when there is no input signal for specific 
    period.
    6) Press 
    qw to switch the item.
     fThe items will switch each time you press the button.
    [AMBIENT LIGHT 
    DETECTION] [OFF]
    Disables the ambient light detection function.
    [ON] Enables the ambient light detection function.
    [NO SIGNAL LIGHTS-OUT] [DISABLE]
    Disables the no signal lights-out function.
    [10SEC.] - [5MIN.] Turns off the light source when there is no input signal for the preset 
    period.
    Select [10SEC.], [20SEC.], [30SEC.], [1MIN.], [2MIN.], [3MIN.], or 
    [5MIN.].
    Note
     f
    [AMBIENT  LIGHT DETECTION] and [NO SIGNAL LIGHTS-OUT] cannot be set when [AUTO POWER SAVE] is set to [OFF]. fThe power indicator  will blink slowly in green while the no signal lights-out function is operating and the light source 
    is turned off.
     f When 
    
    [NO SIGNAL LIGHTS-OUT] is set to anything other than [DISABLE], the conditions to turn on the light source again from the condition 
    that the light source was turned off by this function are as follows.
     g When the signal has been input gWhen on-screen display such as menu screen (OSD) or input guide, a test pattern, or a warning message is displayed gWhen the power < v
    
    /b> button is pressed
     gWhen the operation to disable the shutter function (shutter: open) is performed, such as pressing the  button gWhen the operating environment temperature is around 0
    
      °C (32   °F) and the light source is forced to turn on due to warm-up
     fThe luminance may not be detected correctly when an object is placed on top of the projector , blocking the luminance sensor
    
    . In such a 
    case, it may not operate properly even if [AMBIENT LIGHT DETECTION] is set to [ON].
    Setting [NO SIGNAL SHUT-OFF]
    This is a function to automatically set the power of the projector to st\
    andby mode when there is no input signal for 
    specific period. The time before switching to standby can be set.
    1)
     
    Press 
     as to select [ECO MANAGEMENT].
    2)
     
    Press the  button.
     fThe 
    
    [ECO MANAGEMENT] screen is displayed.
    3)
     
    Press 
     as to select [NO SIGNAL SHUT-OFF].
    4)
     
    Press 
     qw to switch the item.
     fThe items will switch each time you press the button.   
    						
    							Chapter 4 Settings — [PROJECTOR SETUP] menu
    102 - ENGLISH
    [DISABLE]Disables the no signal shut-off function.
    [10MIN.] - [90MIN.] Sets the time in increments of 10 minutes.
    Setting [STANDBY MODE]
    Set the power consumption during standby and whether to enable the [QUICK ST ARTUP] function.
    1)  
    Press 
     as to select [ECO MANAGEMENT].
    2)
     
    Press the  button.
     fThe 
    
    [ECO MANAGEMENT] screen is displayed.
    3)
     
    Press 
     as to select [STANDBY MODE].
    4)
     
    Press 
     qw to switch the item.
     fThe items will switch each time you press the button.
    [NORMAL] Select this item when using the network function during standby.
    [ECO] Select this item to reduce power consumption during standby.
     fProceed to Step  5) when [NORMAL] is selected.
    5)
     
    Press 
     as to select [QUICK STARTUP].
    6)
     
    Press 
     qw to switch the item.
     fThe items will switch each time you press the button.
    [OFF] Disables the [QUICK STARTUP] function.
    [ON] Enables the [QUICK STARTUP] function until the specified time set in [VALID PERIOD] elapses after 
    the projector enters the standby mode. The time until the projection starts after the power is turned on 
    will be reduced during the period when the [QUICK STARTUP] function is valid.
     f
    Proceed to Step  7) when [ON] is selected.
    7)
     
    Press the  button.
     f The 
    
    [QUICK STARTUP] screen is displayed.
    8)
     
    Press 
     qw to switch [VALID PERIOD].
     fThe items will switch each time you press the button.
    [30MIN.]
    Sets the time until the [QUICK STARTUP] function is disabled after the projector enters the standby 
    mode.
    Select a desired valid period.
    [60MIN.]
    [90MIN.]
    Note
     f
    When [STANDBY MODE] is set to [NORMAL], the network function can be used during standby. fWhen [ST
    ANDBY MODE] is set to [ECO], the network function and the audio output function cannot be used during standby. Also, some 
    RS
    - 232C commands cannot be used.
     fWhen [ST
    
    ANDBY MODE] is set to [ECO], it takes longer for the projection to start after the power is turned on, compared to when set to 
    [NORMAL].
     f [ST
    
    ANDBY MODE] is fixed to [NORMAL] when the [PROJECTOR SETUP] menu → [SCHEDULE] is set to [ON].
     f[QUICK ST
    
    ARTUP] cannot be set when [STANDBY MODE] is set to [ECO].
     fWhen [QUICK ST
    
    ARTUP] is set to [ON], the power consumption during standby becomes high during the period when the [QUICK 
    STARTUP] function is valid.
     f If [QUICK ST
    
    ARTUP] is set to [ON], the [QUICK STARTUP] function is disabled when the time set in [VALID PERIOD] elapses after the 
    projector enters the standby mode. The startup time and power consumption will be the same as when [QUICK STARTUP] is set to [OFF].
     f When [QUICK ST
    
    ARTUP] is set to [ON], the power indicator  blinks in red while in the standby mode during the 
    period when the [QUICK STARTUP] function is valid. When [IN STANDBY MODE] in [AUDIO SETTING] is set to [OFF], the power indicator 
     will change to a red light when the specified time set in [VALID PERIOD] elapses after the projector enters the 
    standby mode.
     f When [QUICK ST
    
    ARTUP] is set to [ON], the period when the [QUICK STARTUP] function is valid will be added as the projector runtime.   
    						
    							Chapter 4 Settings — [PROJECTOR SETUP] menu
    ENGLISH - 103
    [OPERATION SETTING]
    Set the operation method of the projector.
    The settings are reflected when “Initial setting (operation setting)” (x
      page   43) in the [INITIAL SETTING] 
    screen is already set.
    If you change the settings while using the projector, the duration until the luminance of light source decreases by 
    half may shorten or the luminance may decrease.
    Setting [OPERATING MODE]
    1) Press  as to select [OPERATION SETTING].
    2)  
    Press the  button.
     fThe 
    
    [OPERATION SETTING]  screen is displayed.
    3)
     
    Press 
     as to select [OPERATING MODE].
    4)
     
    Press 
     qw to switch the item.
     fThe items will switch each time you press the button.
    [NORMAL] Set this item when high luminance is required. The estimated runtime is approximately 20   000 hours.
    [ECO] The luminance will decrease compared to [NORMAL], but set this item to increase the expected life of 
    the light source. The estimated runtime is approximately 24
      000 hours.
    [SILENT] The luminance will decrease compared to [NORMAL], but set this item to prioritize the operation with 
    less noise. The estimated runtime is approximately 20
      000 hours.
    [LONG LIFE1] The luminance will decrease compared to [ECO], but set this item to increase the expected life of the 
    light source. The estimated runtime is approximately 43
      000 hours.
    [LONG LIFE2] The luminance will decrease compared to [LONG LIFE1], but set this item to increase the expected 
    life of the light source. The estimated runtime is approximately 61
      000 hours.
    [LONG LIFE3] The luminance will decrease compared to [LONG LIFE2], but set this item to increase the expected 
    life of the light source. The estimated runtime is approximately 87
      000 hours.
    [USER1] [MAX LIGHT OUTPUT LEVEL] and [LIGHT OUTPUT] can be set individually.
    [USER2]
    [USER3]
    5) Press  as to select [APPLY].
    6)  
    Press the  button.
    7)
    
     
    When the confirmation screen is displayed, press  qw
    
     to select [OK], and press the  button.
    Note
     f The [OPERA TING MODE] setting does not return to the factory default setting even if the [PROJECT OR SETUP] menu → [INITIALIZE] → 
    [ALL USER DATA] is executed.
     f If the runtime exceeds 20
    
      000 hours, replacement of the components inside the projector may be required. Consult your dealer for details.
    Setting [MAX LIGHT OUTPUT LEVEL]
    Adjust the maximum level to correct screen brightness according to the changes in brightness of the light source.
    1) 
    Press 
     as to select [OPERATION SETTING].
    2)
     
    Press the  button.
     fThe 
    
    [OPERATION SETTING]  screen is displayed.
    3)
     
    Press 
     as to select [MAX LIGHT OUTPUT LEVEL].
    4)
     
    Press 
     qw to adjust.
    Operation AdjustmentRange of adjustment
    Press w. Increases the maximum level of brightness correction.
    5.0
      % - 100.0   %
    Press q. Decreases the maximum level of brightness correction.
    5) Press 
    as to select [APPLY].   
    						
    							Chapter 4 Settings — [PROJECTOR SETUP] menu
    104 - ENGLISH
    6) Press the  button.
    7)  
    When the confirmation screen is displayed, press  qw
    
     to select [OK], and press the  button.
    Note
     f [MAX LIGHT  OUTPUT LEVEL] cannot be adjusted when [OPERATING MODE] is set to [NORMAL], [ECO], [SILENT], [LONG LIFE1], 
    [LONG LIFE2], or [LONG LIFE3].
     f The brightness is corrected using this setting when the [PROJECT OR SETUP] menu 
    
    → [BRIGHTNESS CONTROL] → [BRIGHTNESS 
    CONTROL SETUP] → [CONSTANT MODE] is set to [AUTO] or [PC].
     f The [MAX LIGHT
    
     OUTPUT LEVEL] setting does not return to the factory default setting even if the [PROJECTOR SETUP] menu → 
    [INITIALIZE]  → [ALL USER DATA] is executed.
    Setting [LIGHT OUTPUT]
    Adjust the brightness of light source.
    The [LIGHT OUTPUT] setting is synchronized with the [PROJECTOR SETUP] menu → [LIGHT OUTPUT]. The 
    most recent setting is reflected in both items.
    1)
     
    Press 
     as to select [OPERATION SETTING].
    2)
     
    Press the  button.
     fThe 
    
    [OPERATION SETTING]  screen is displayed.
    3)
     
    Press 
     as to select [LIGHT OUTPUT].
    4)
     
    Press 
     qw to adjust.
    Operation Adjustment
    Range of adjustment
    Brightness Runtime (estimate)
    Press w. The screen becomes brighter. The runtime becomes shorter.
    5.0
      % - 100   %
    Press q. The screen becomes darker. The runtime becomes longer.
    5) Press 
    as to select [APPLY].
    6)  
    Press the  button.
    7)
    
     
    When the confirmation screen is displayed, press  qw
    
     to select [OK], and press the  button.
    Note
     f [LIGHT OUTPUT] can be adjusted individually for each setting item of [OPERATING MODE]. fIn such a case when configuring multiple screens with multiple projectors, uniformity of brightness between multiple screens can be 
    obtained by adjusting [LIGHT
     OUTPUT].
    Interrelation of luminance and runtime
    The projector can be operated at arbitrary brightness and duration of use by combining the settings of [MAX 
    LIGHT OUTPUT LEVEL], [LIGHT OUTPUT], and [CONSTANT MODE] in [BRIGHTNESS CONTROL SETUP].
    Interrelation of luminance and runtime is as follows. Make the settings depending on your desired duration of use 
    and brightness of the projected image.
    Values of the luminance and runtime are rough estimations.
     fT
    
    o set the projector based on the duration of use
    Duration of use  (hour) When [CONSTANT MODE] is set to [OFF] When [CONSTANT MODE] is set to [AUTO] or [PC]
    [MAX LIGHT 
    OUTPUT LEVEL]  (%) [LIGHT OUTPUT] 
    (%) Luminance (lm) [MAX LIGHT 
    OUTPUT LEVEL]  (%) [LIGHT OUTPUT] 
    (%) Luminance (lm)
    20
      000 100.0 100.05
      000100.0 50.02
      500
    24
      000 100.0 68.03
      400100.0 40.02
      000
    27
      000 100.0 28.01
      400100.0 34.01
      700
    31
      000 ―――100.0 26.01
      300
    35
      000 ―――100.0 20.01
      000
    40
      000 ―――100.0 14.0700   
    						
    							Chapter 4 Settings — [PROJECTOR SETUP] menu
    ENGLISH - 105
     fTo set the projector based on luminance
    Luminance (lm) When [CONSTANT MODE] is set to [OFF] When [CONSTANT MODE] is set to [AUTO] or [PC]
    [MAX LIGHT 
    OUTPUT LEVEL]  (%) [LIGHT OUTPUT] 
    (%) Runtime (hour) [MAX LIGHT 
    OUTPUT LEVEL]  (%) [LIGHT OUTPUT] 
    (%) Runtime (hour)
    5
      000 100.0 100.020
      000― ――
    4
      500 100.0 90.021
      500100.0 90.04
      400
    4
      000 100.0 80.022
      800100.0 80.07
      800
    3
      500 100.0 70.023
      900100.0 70.011
      600
    3
      000 100.0 60.025
      000100.0 60.015
      700
    2
      500 100.0 50.025
      800100.0 50.020
      000
    2
      000 100.0 40.026
      400100.0 40.024
      000
    1
      500 100.0 30.026
      900100.0 30.029
      000
    Note
     fUnder influences of characteristics of each light source, conditions of use, installation environment, etc., the runtime may be shorter than the 
    estimation.
     fThe duration of use is referred to as the runtime when you use the proje\
    ctor successively
    
    . The duration of use is an estimated duration and 
    is not the warranty period.
     f If the runtime exceeds 20
    
      000 hours, replacement of the components inside the projector may be required. Consult your dealer for details.
    Setting [BRIGHTNESS CONTROL SETUP]
    Set the operation of the brightness control function.
    The [BRIGHTNESS CONTROL SETUP] setting is synchronized with the [PROJECTOR SETUP] menu → 
    [BRIGHTNESS CONTROL]  → [BRIGHTNESS CONTROL SETUP]. The most recent setting is reflected in both 
    items.
    1)
     
    Press 
     as to select [OPERATION SETTING].
    2)
     
    Press the  button.
     fThe 
    
    [OPERATION SETTING]  screen is displayed.
    3)
     
    Press 
     as to select [CONSTANT MODE].
    4)
     
    Press 
     qw to switch the item.
     fThe items will switch each time you press the button.
    [OFF] Does not correct the brightness of the screen by the brightness sensor.
    [AUTO] Corrects the brightness of the screen by the brightness sensor.
    When the brightness of light source or white balance changes, the bright\
    ness of the screen is 
    automatically corrected.
    [PC] Synchronizes nine or more projectors using a computer and the dedicated software “Multi Monitoring 
    & Control Software”
    *1.
    *1 “Multi Monitoring & Control Software” is included in the supplied CD-ROM.
     f
    Proceed to Step  7) when [PC] is selected.
    5)
     
    Press 
     as to select [LINK].
    6)
     
    Press 
     qw to switch the item.
     fThe items will switch each time you press the button.
    [OFF] Performs correction by the brightness sensor on one projector without sy\
    nchronizing with the other 
    projectors.
    The duration that the constant brightness is kept will become longer by setting the value of [LIGHT
     
    OUTPUT] smaller.
    [GROUP A]
    [GROUP B]
    [GROUP C]
    [GROUP D] Performs correction by the brightness sensor in multiple projectors in s\
    ynchronization.
    Up to four groups (A to D) can be set within the same subnet by using the network function.
    Up to eight projectors can be registered and synchronized in one group.
    7) Press 
    as to select [CALIBRATION TIME].   
    						
    							Chapter 4 Settings — [PROJECTOR SETUP] menu
    106 - ENGLISH
    8) Press the  button.
     fThe projector will go into the adjustment mode (the time is blinking).
    9)
    
     
    Press 
     qw to select “hour” or “minute”, and press as or the number ( - ) buttons to set a 
    time.
     f Selecting “hour” allows setting of only the hour in increments of one hour , and selecting “minute” allows 
    setting of only the minute in increments of one minute between 00 and 59\
    .
     f When the time is not specified, select [OFF] between 23 and 00 of the hour , or between 59 and 00 of the 
    minute.
    10)
    
     
    Press the  button.
     f[CALIBRA
    
    TION TIME] is set.
     fBrightness and color are measured at the specified time. 
    
    The dynamic contrast function does not operate 
    during measurement.
    11)
     
    Press 
     as to select [CALIBRATION MESSAGE].
    12)
     
    Press 
     qw to switch the item.
     fThe items will switch each time you press the button.
    [ON] Displays the message while executing the calibration.
    [OFF] Does not display the message while executing the calibration.
    13) Press as to select [APPLY].
    14)  
    Press the  button.
     fWhen [CONST
    
    ANT MODE] in [BRIGHTNESS CONTROL SETUP] is set to anything other than [OFF], the 
    brightness and white balance of light source at the time when the  button is pressed is recorded 
    as the standard brightness and white balance.
     f The group name is displayed in the screen of the projectors set as the same group when the  
    button is pressed while [LINK] is set to an item from [GROUP
    
     A] to [GROUP D].
    LINKGROUP A
    15) When the confirmation screen is displayed, press  qw  to select [APPLY], and press the  
    button.
    Note
     f When [CONST ANT MODE] in [BRIGHTNESS CONTROL SETUP] is set to [AUTO] or [PC], keep the shutter function disabled (shutter: 
    open) for at least two minutes, since the brightness sensor calibration is performed after the [BRIGHTNESS CONTROL  SETUP] setting has 
    been completed.
     f If the shutter function is enabled (shutter: closed) within approximately 10 minutes after the light source has turned on while [CONST ANT
    
     
    MODE] in [BRIGHTNESS CONTROL SETUP] is set to [AUTO] or [PC], brightness and color cannot be measured. Therefore, brightness 
    may be corrected approximately two minutes after the shutter function is disabled (shutter: open).
     f Since the brightness and the color of the light source do not stabilize for approximately eight minutes after turning on the light source when 
    the projector operates with [CONST
    
    ANT MODE] in [BRIGHTNESS CONTROL SETUP] set to [AUTO] or [PC], the brightness and the color 
    of the light source will be automatically measured approximately eight minutes after the light source is turned on.  A correction is made based 
    on this measurement result so that the brightness and the color will be \
    the same as the standard brightness and color when adjusted with 
    the brightness control.
     f When the projector operates with [CONST
    
    ANT MODE] in [BRIGHTNESS CONTROL SETUP] set to [AUTO] or [PC], the items of 
    [OPERATING MODE] and [LIGHT OUTPUT] cannot be changed.
     f When the projector operates with [CONST
    
    ANT MODE] in [BRIGHTNESS CONTROL SETUP] set to [AUTO], and [LINK] set to [OFF], the 
    brightness will be corrected until it reaches the value set in [MAX LIGHT  OUTPUT LEVEL].
     fThe variation in brightness may increase due to dust accumulating on the\
     lens, screen, or inside the projector
    
    , depending on the installation 
    environment of the projector.
     f When the variation in brightness has increased due to aging of the light\
     source, or when you replaced the light source, readjust the 
    brightness control.
     fWhen the projector is used continuously for more than 24 hours, set the [CALIBRA TION 
    
    TIME] in [BRIGHTNESS CONTROL SETUP]. If it is 
    not set, correction will not be performed automatically.
     f The brightness control function and the dynamic contrast function will o\
    perate simultaneously
    
    , but the dynamic contrast function will not 
    operate while measuring the brightness and the color.
     f The [CALIBRA
    
    TION TIME] setting will be reflected when you enter the time.
     fThe [CALIBRA
    
    TION MESSAGE] setting will be reflected when items are switched using  qw.   
    						
    							Chapter 4 Settings — [PROJECTOR SETUP] menu
    ENGLISH - 107
    [LIGHT OUTPUT]
    Adjust the brightness of light source.
    The setting is reflected when it is already set with “Initial setting (operation setting)” (x
      page   43) in the [INITIAL 
    SETTING]  screen or with the [PROJECTOR SETUP] menu → [OPERATION SETTING]. The [LIGHT OUTPUT] 
    setting is synchronized with the [PROJECTOR SETUP] menu → [OPERATION SETTING]  → [LIGHT OUTPUT]. 
    The most recent setting is reflected in both items.
    1)
     
    Press 
     as to select [LIGHT OUTPUT].
    2)
     
    Press 
     qw to adjust.
    Operation Adjustment
    Range of adjustment
    Brightness Runtime (estimate)
    Press w. The screen becomes brighter. The runtime becomes shorter.
    5.0
      % - 100.0   %
    Press q. The screen becomes darker. The runtime becomes longer.
    Note
     f
    [LIGHT OUTPUT] can be adjusted individually for each setting item of [OPERATING MODE]. fIn such a case when configuring multiple screens with multiple projectors, uniformity of brightness between multiple screens can be 
    obtained by adjusting [LIGHT
     OUTPUT].
    [BRIGHTNESS CONTROL]
    The projector is equipped with a brightness sensor to measure brightness and color of the light source, and 
    corrects brightness and white balance of the projected image according t\
    o the changes in brightness and color of 
    the light source.
    By using this function, in such a condition that multiple screens are configured using multiple projectors, you can 
    reduce changes in overall brightness and white balance of the multiple s\
    creens due to aging of the light source 
    and suppress variation in brightness and white balance to preserve unifo\
    rmity.
    The setting is reflected when it is already set with “Initial setting (operation setting)” ( x
      page   43) in the [INITIAL 
    SETTING]  screen or with the [PROJECTOR SETUP] menu → [OPERATION SETTING]. The [BRIGHTNESS 
    CONTROL SETUP] setting is synchronized with the [PROJECTOR SETUP] menu → [OPERATION SETTING]  → 
    [BRIGHTNESS CONTROL SETUP]. The most recent setting is reflected in both items.
    Setting [BRIGHTNESS CONTROL SETUP]
    Set the operation of the brightness control function.
    1)
     
    Press 
     as to select [BRIGHTNESS CONTROL].
    2)
     
    Press the  button.
     fThe 
    
    [BRIGHTNESS CONTROL] screen is displayed.
    3)
     
    Press 
     as to select [BRIGHTNESS CONTROL SETUP].
    4)
     
    Press the  button.
     fThe 
    
    [BRIGHTNESS CONTROL SETUP] screen is displayed.
    5)
     
    Press 
     as to select [CONSTANT MODE].
    6)
     
    Press 
     qw to switch the item.
     fThe items will switch each time you press the button.
    [OFF] Does not correct the brightness of the screen by the brightness sensor.
    [AUTO] Corrects the brightness of the screen by the brightness sensor.
    When the brightness of light source or white balance changes, the bright\
    ness of the projected image 
    is automatically corrected.
    [PC] Synchronizes nine or more projectors using a computer and the dedicated software “Multi Monitoring 
    & Control Software”
    *1.
    *1 “Multi Monitoring & Control Software” is included in the supplied CD-ROM.
     f
    Proceed to Step  9) when [PC] is selected.
    7)
     
    Press 
     as to select [LINK].   
    						
    							Chapter 4 Settings — [PROJECTOR SETUP] menu
    108 - ENGLISH
    8) Press qw to switch the item.
     fThe items will switch each time you press the button.
    [OFF] Performs corrections by the brightness sensor on a single projector with\
    out synchronizing with the 
    other projectors.
    The duration that the constant brightness is kept will become longer by setting the value of [LIGHT
     
    OUTPUT] smaller.
    [GROUP A]
    [GROUP B]
    [GROUP C]
    [GROUP D] Performs correction by the brightness sensor in multiple projectors in s\
    ynchronization.
    Up to four groups (A to D) can be set within the same subnet by using the network function.
    You can register and synchronize up to eight projectors in one group.
    9) Press 
    as to select [CALIBRATION TIME].
    10)  
    Press the  button.
     fThe projector is in the adjustment mode (the time is blinking).
    1
    
    1)  
    Press 
     qw to select “hour” or “minute”, and press as or the number ( - ) buttons to set a 
    time.
     f Selecting “hour” allows setting of only the hour in increments of one hour , and selecting “minute” allows 
    setting of only the minute in increments of one minute between 00 and 59\
    .
     f When the time is not specified, select [OFF] between 23 and 00 of the hour , or between 59 and 00 of the 
    minute.
    12)
    
     
    Press the  button.
     f[CALIBRA
    
    TION TIME] is set.
     fBrightness and color are measured at the specified time. 
    
    The dynamic contrast function does not operate 
    during measurement.
    13)
     
    Press 
     as to select [CALIBRATION MESSAGE].
    14)
     
    Press 
     qw to switch the item.
     fThe items will switch each time you press the button.
    [ON] Displays messages during calibration.
    [OFF] Does not display messages during calibration.
    15) Press as to select [APPLY].
    16)  
    Press the  button.
     fIf the  button is pressed with [CONST
    
    ANT MODE] set to anything other than [OFF], the 
    brightness and white balance of light source at the time when the button\
     is pressed is recorded as the 
    standard brightness and white balance.
     f If the  button is pressed when [LINK] is set from [GROUP
    
     A] to [GROUP D], the group name is 
    displayed on the screens of projectors that have been set in the same gr\
    oup.
    LINK GROUP A
    Note
     fWhen [CONST ANT MODE] is set to [AUTO] or [PC], keep the shutter function disabled (shutter: open) for at least two minutes, since the 
    brightness sensor calibration is performed after the [BRIGHTNESS CONTROL  SETUP] setting has been completed.
     fIf the shutter function is enabled (shutter: closed) within approximately 10 minutes after the light source has been turned on while the 
    projector operates with [CONST
    
    ANT MODE] set to [AUTO] or [PC], brightness and color cannot be measured. Therefore, brightness may be 
    corrected approximately two minutes after the shutter function is disabled (shutter: open).
     f If the projector is operating with [CONST
    
    ANT MODE] set to [AUTO] or [PC], the brightness and color of the light source do not stabilize for 
    approximately eight minutes after the light source is turned on.  Therefore, the brightness and color of the light source will be automatically 
    measured after approximately eight minutes have elapsed after the light source is turned on.  A correction is made based on this 
    measurement result so that the brightness and color for the image will b\
    e the same as the standard brightness and color when adjusted with 
    the brightness control.
     f When the projector operates with [CONST
    
    ANT MODE] set to [AUTO], and [LINK] set to [OFF], the brightness will be corrected until it 
    reaches the value set in [MAX LIGHT OUTPUT LEVEL].
     f The variation in brightness may increase due to dust accumulating on the\
     lens, screen, or inside the projector
    
    , depending on the installation 
    environment of the projector.
     f When the variation in brightness has increased due to aging of the light\
     source, or when you replaced the light source, readjust the 
    brightness control.   
    						
    							Chapter 4 Settings — [PROJECTOR SETUP] menu
    ENGLISH - 109
     fWhen the projector is used continuously for more than 24 hours, set [CALIBRA TION  TIME]. If it is not set, correction will not be performed 
    automatically.
     f The brightness control function and the dynamic contrast function will o\
    perate simultaneously
    
    , but the dynamic contrast function will not 
    operate while measuring the brightness and the color.
     f The [CALIBRA
    
    TION TIME] setting will be reflected when you enter the time.
     fThe [CALIBRA
    
    TION MESSAGE] setting will be reflected at the time when the item is switched using  qw.
    Displaying [BRIGHTNESS CONTROL STATUS]
    Display the brightness control status.
    1)
     
    Press 
     as to select [BRIGHTNESS CONTROL].
    2)
     
    Press the  button.
     fThe 
    
    [BRIGHTNESS CONTROL] screen is displayed.
    3)
     
    Press 
     as to select [BRIGHTNESS CONTROL STATUS].
    4)
     
    Press the  button.
     fThe 
    
    [BRIGHTNESS CONTROL STATUS] screen is displayed.
    [BRIGHTNESS CONTROL STATUS] screen display example
    When [CONSTANT MODE] is set to [OFF]
    The screen shows the status that the brightness control is disabled.
    1
    RETURN
    BRIGHTNESS CONTROL STATUS
    CONSTANT MODE PROJECTOR OFFMENU
    When [CONSTANT MODE] is set to [AUTO], and [LINK] is set to [OFF]
    The screen shows the status of the brightness control in one projector.
    5
    1
    6
    RETURN
    LINK
    PROJECTOR OFF
    BRIGHTNESS CONTROL STATUSMENU   
    						
    							Chapter 4 Settings — [PROJECTOR SETUP] menu
    110 - ENGLISH
    When [CONSTANT MODE] is set to [AUTO], and [LINK] is set to [GROUP A] through [GROUP D]
    The screen shows the status of the brightness control of synchronized projectors (up to eight units), including the 
    projector being controlled through the on-screen menu.
    2 1
    3
    4
    5 
    7
    8
    1:
    2:
    3:
    4:
    5:
    6:
    7:192. 168. 30.   2
    192. 168. 30.   3
    192. 168. 30.   4
    LINK
    UPDATE PROJECTOR
    GROUP A
    PROJECTOR2
    PROJECTOR3
    BRIGHTNESS CONTROL STATUS
    MENU SELECT
    When [CONSTANT MODE] is set to [PC]
    5
    1
    6
    RETURN
    CONSTANT MODE
    PROJECTOR PC
    BRIGHTNESS CONTROL STATUSMENU
    1 Display the name of the projector
    .
    2  
    Display the synchronized group.
    3
    
     
    Display the IP
      address of the projector.
    4
     
    Display the names and IP
      addresses of projectors in same group detected over the network.
    5
     
    Display the status by color
     .
    Green: There is an allowance for brightness correction.
    Yellow: There is little allowance for brightness correction.
    Red: There is a brightness control error.
    6
     
    Display error detailed messages.
    7
    
     
    Display error messages.
    When the message [Failed to apply BRIGHTNESS CONTROL
    
     to some projectors.] appears, it means that synchronization with the 
    projector displayed in red has failed.
    Press as to select the projector displayed in red, and press the  button to display the error details.
    8
     
    Update to the latest status information.
     r Error details
    Error message Measures to take
    [Exceed maximum number of 
    projectors.]
     f Limit the number of projectors in one group to eight.
     fT
    
    o synchronize nine or more projectors, use a PC and the dedicated software “Multi Monitoring & 
    Control Software”
    *1.
    [Please check the COMMAND 
    CONTROL setting.]
     f Set [NETWORK CONTROL]  →
    
     [COMMAND CONTROL] to [ON] for the projector in error.
     fSet [NETWORK CONTROL]  →
    
     [COMMAND PORT] of all projectors to be linked to the same value.
    [Please check the USER NAME 
    and PASSWORD in the COMMAND 
    CONTROL setting.]
     f Assign the same [User name] and [Password] strings that have web control administrator rights to 
    all projectors to be linked.
    [Cannot apply BRIGHTNESS 
    CONTROL. Please check projector 
    status.]
     f The projector is in standby
    
    . Switch on the power.
    [Brightness Sensor Error]
     f There is a problem with the brightness sensor
    
    . If problems persist even after switching on the 
    power, consult your dealer.