Home > Samsung > Communications System > Samsung Dcs 50si General Description Manual

Samsung Dcs 50si General Description Manual

Here you can view all the pages of manual Samsung Dcs 50si General Description Manual. The Samsung manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 11


access memory (NV-RAM) located on the remov-
able SMEM card. It is protected by a super capaci-
tor providing seven days of memory protection in
the event of loss of AC power to the system.
2.4 INTERFACE CARDS
2 SLI
This card is installed in a dedicated slot on the KSU
motherboard. The card provides two single line tele-
phone interfaces equipped with OPX protection and
the ability to provide a loop disconnect signal. This
is the same card used on the DCS Compact.
2 x 4 DLI
This card provides...

Page 12


2.3
2 E & M x 4 DLI
This card provides two two wire (TL11M) tie line interfaces and four 1B+D DLI ports.
KDb’s cannot be used with this card. This is the same card used on the DCS Compact.
S4BRI
This card provides 4 ISDN Basic Rate Interface (BRI) S/T circuits with the ability to sup-
port two channels per circuit for a total of 8 channels. A system can have up to six of these
cards.  These S/T circuits can be configured for station or trunk use. An NT1 is required
for connection to a telephone...

Page 13


This fully featured self contained system is connected
directly to the DCS 50si data bus and communicates
with the DCS 50si system processor. This design means
that installation time is minimized, operation is stream-
lined and many features can be implemented that are
not normally possible with older conventional stand
alone Voice Mail/Auto Attendant systems.
All power to run this self contained system comes from
the DCS 50si telephone system power supply. The DCS
50si power supply is rated...

Page 14


2.5
2.5 STATION EQUIPMENT
LCD 24B Keyset (See Figures 2–5)
Built-in speakerphone
24 programmable keys (16 with tri-colored
LEDs)
Four fixed function keys
32 character display (2 x 16) with three
associated soft keys and a scroll key
UP/DOWN buttons for digital control of
speaker, handset and ringer volumes
Eight selectable ring tones
Desk- or wall-mounted
Available in almond or charcoal
STD 24B Keyset (See Figures 2–6)
Built-in speakerphone
24 programmable keys (16 with tri-col-
ored...

Page 15


2.6
Basic 12B Model Keyset
(see Figures 2–8)
Built-in speakerphone
12 programmable keys (six with tri-col-
ored LEDs)
Four fixed function keys
UP/DOWN buttons for digital control of
speaker, handset and ringer volumes
Eight selectable ring tones
Desk- or wall-mounted
Available in almond or charcoal
7 Button Model Keyset (see Figures 2–9)
7 programmable keys
Three fixed function keys
UP/DOWN buttons for digital control of
speaker and ringer volumes
Eight selectable ring tones
Desk or...

Page 16


2.7
FIGURE 2–11
Door Phone Interface Module (DPIM) and
Door Phone (see Figures 2–12 and 2–13)
The DPIM adapts any DLI circuit for use with
the door phone unit
Commonly used to request entry through
locked doors (interior or exterior) or as a
room monitoring box
Provides contact control to be used with cus-
tomer-provided electric door lock
Door phone is wall-mounted
Door phone is weather resistant
FIGURE 2–12
FIGURE 2–13       

Page 17


2.8
Serial Interface Module (SIM) (See Figure 2–14)
Provides an RS232 connection required for SMDR, PCMMC and TSAPI
Connects to any DLI circuit
FIGURE 2–14
FIGURE 2–15
Computer Telephony Module (CTM) (See Figure 2–15)
Provides RS232 connection via DB9 for TAPI applications
Connects with any DLI port     

Page 18


2.9
64 Button Module (See Figure 2–16)
64 programmable keys
Available in almond and charcoal
A maximum of 2 can be assigned
to any DCS keyset to provide
additional programmable keys
A maximum of 4 per DCS System
FIGURE 2–16
Single Line Telephone (See Figure 2–17)
Four fixed function keys: hold, flash, new
call, and monitor.
Data Port: selectable to share station ex-
tension or utilize a separate extension
On hook dialing
Message Waiting/Ring Indicator
Desk or wall mounted
Ring volume...

Page 19


3.1
PART 3. SPECIFICATIONS
The following tables provide technical data for the DCS 50si hybrid/key telephone system.
3.1 ELECTRICAL SPECIFICATIONS
AC INPUT 112 (88–132) VAC (48–63 Hz)
POWER CONSUMPTION (MAX) 97 WATTS MAXIMUM FUSE RATING 5 AMP
BTU RATING (MAX) 5.5 BTU/MINUTE
DC OUTPUT +5 VOLTS 2.5 AMPS MAX
-5 VOLTS 0.5 AMPS MAX
-48 VOLTS 1.2 AMPS MAXIMUM
BATTERIES 10–40 AMPS 48 VOLTS
MAXIMUM CHARGE CURRENT 0.4 A
MAXIMUM DISCHARGE RATE 2.5 A
3.2DIMENSIONS AND WEIGHTS
HEIGHT WIDTH DEPTH WEIGHT
DCS...

Page 20

3.2
3.3ENVIRONMENTAL LIMITS
OPERATING TEMPERATURE 32–104 °F/1–40 °C 
STORAGE TEMPERATURE -13–158 °F/-10.5–70 °C
HUMIDITY 10%-90% NON-CONDENSING
3.4CABLE REQUIREMENTS
EQUIPMENT CABLE AWG MAX FEET MAX METERS
DIGITAL KEYSETS 1 PR. TWISTED 24 1300 400
ADD-ON MODULES 1 PR. TWISTED 24 1300 400
SINGLE LINE STATION 1 PR. TWISTED 24 3000 1 KM
DOOR PHONE 2 PR. TWISTED 24 330* 100
*This is the maximum length of the cable between the door phone and the \
DPIM. The 
DPIM can be installed up to 900 cable feet from the...