    Have a look at the manual Anaheim HMIPLC Release note for Version 16 all20110601 Users Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 523 Anaheim manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							
     
    28 Group components   
    Combine multi components or graphics and save them to the Group components 
    Library,  so that other projects can us e them, the file format of Group components 
    Library is .pgl. 
    The method of entering the  Edit Box of Group components Library: 
    Click menu , Draw>>>Group components>>>Use the group element,  or right 
    click the blank part in the edit window, select the  Group then ,click the  Use the group 
    element,  then pop up the  Edit Box of Group components Library 
     
    Export Library 
    Click the Export Library,  then the current Group components Library is save to the  
    						
    							
    path users defined. So that it can be imported by other projects   
    Import Library: the default path of Group components Library is under the Ev5000 
    installation catalogue named UerLib. And the us er can also import the library from the 
    customized path: click the  Import Library, and find the path where the  Group graphics 
    Library  saved, select the library, then click  Open, so the library is added to  Group 
    graphics Library  of current project   
    New Library 
      Click the New Library,  pop up the following dialog box, input a name for the new 
    library.  And the default saving path is the in stallation catalogue named UserLib   
     
    Delete Library 
    Click the Delete Library,  the current group graphics library will be deleted 
     
    Click (Y) to delete the current group graphics library in the project , and click (N) to 
    cancel the operation.   
    Delete All Groups 
    Click the  Delete All Groups  to delete the all the groups, and all the graphics or 
    elements in the library will be deleted 
     
    Delete Group Components   
    Click the  Delete Group Components,  the selected component or graphic will be 
    deleted  
    						
    							
     
     
    For Delete Library, Delete All Groups, Delete Group 
    Components , they delete the corresponding files in the usrlib 
    folder of EV5000 installation catalog directly   
     
    Place Group Components 
    Click the  Place Group Components,, the selected  graphic will be placed in the 
    current edit window. 
    Example: 
    How to add the group graphics to the new group graphics library: 
    1 Click the menu ,then  Draw>>>Group components >>>Use the group  elements, 
    pop up a dialog box, then click New Library,  input the name: group. As shown in the 
    following picture: 
     
    Click  OK.  there will be new blank library., As shown in the following picture: 
      
    						
    							
    2 Place three rectangle in the edit window. As shown in the following picture: 
     
    Select all the three rectangle, right click, Groups>>>Save the group element ,  then 
    click th e Save Group Components  in the Edit Box of Components Library, pop up a 
    dialog box as follows: 
     
    3  Input  graphic 1  in the name box, click  OK, so the three rectangle named graphic 1 
    i s added into the library named  group, as follows:  
    						
    							
     
    4 If you want to  add more group elements to the group  again , the method is the 
    same as above, when save the group elements ,just select the  group in the Group 
    Components  list. 
    29 Add Broadcast number in Modbus RTU , as in the following picture: 
     
    30 Change Window (Ignore the window 0) 
    In the Plc Control,  add a option of Change Window (ignore the window 0), as 
    shown in the following picture:  
    						
    							
     
    The difference between the Change Window and Change Window (Ignore the 
    window 0) in PLC Control: 
    Change Window:  when the window number is 0, change to the window 0  
    Change Window (Ignore the window 0): when the window is 0, don’t change the 
    widow 
     
    31 The popped up position of Direct/ Indirect window is variable 
    The pop up position of Di rect/ Indirect window can be controlled by register 
    The corresponding settings: 
    1 Select the  Variable Display Coordinates:  
    						
    							
     
    Corresponding attributes are as follows: 
    X Coordinate of popped up 
    window 
    Y Coordinate of popped up 
    window 
    First address First address+1 
    So the popped up position of Direct/ Indirect window is controlled by two register 
    addresses  , X Coordinate is controlled by the first  address, Y Coordinate is controlled by 
    the first address +1,  
    But for some special PLC, for example. S7-200, the addresses must be even, as 
    shown in the following picture, VW80 contro ls the X coordinate VW82 controls the Y 
    coordinate.  
    						
    							
     
    32 The method to use the keyboard 
        In EV5000 Group Components Library, there are 21 default types of keyboards 
    to choose. They are: 
    Three different styles of  small hexadecimal keyboards : HEX_S_T1~T3; decimal 
    number keyboard of NUMERAL_S_T1~T3;  ASCII keyboard: ASCII_S_T1~T3. these 
    keyboards are applicable to the small size HMI under 320*240 resolution ratio 
    Three different styles of middle hexadecim al keyboards, HEX_M_T1~T3; decimal 
    number keyboard, NUMERAL_M_T1~T3; ASCII keyboard, ASCII_M_T1~T3; these 
    keyboard are applicable to the small big  size HMI above 320*240 resolution ratio 
    Three different styles of small  decimal number keyboards of gray, 
    NUMERAL_S_L1~L3; these keyboards are applicable to 4300M of 320*234 gray scale, 
    HMI of gray scale also can use the co lor keyboards, and the effect is ok 
    Then introduce how to call the keyboards in the  Group Components Library: 
     1 Click the Draw menu>>>Group component  >>>Use the group elements  or right 
    click the blank part  of the window, then  Groups>>> Use the group elements, so pop up 
    the dialog box titled  Edit Box Of Group Components Library,  chose  keyboard  in the 
    Group components list. Choose NUMERAL_S_T1 in the  Preview, then click the  Place 
    Group components, as shown in the following picture:  
    						
    							
     
    2 Then pop up the dialog box titled Replace Confirm Dialog, choose Yes All: 
     
    3 Close the Edit Box Of Group Components Library, so the keyboard is 
    displayed in the window: 
     
    4 Place the keyboard in the fr ame 9, double click to show the  Window Attribute,  
    						
    							
    change the Width and Height of the window , select the Keyboard page  in Special 
    Attribute  
     
    In the window where the keyboard placed ,make sure select the 
    Keyboard page  in Special Attribute  
    5  Place a Number Input com ponent in frame 0, select the Specified Keyboard 
    9:Frame 9  in Keyboard Setting  option. As shown in the followings picture: 
     
    5  Offline simulation, click the Number Input component, pop up the keyboard 
    just placed in frame 9.As show n in the followings picture: 
     
    Then introduce the use of ASCII keyboard: 
    1 Support the case: click Caps key to switch the case.  
    						
    All Anaheim manuals Comments (0)