Home > Anthem > Projector > Anthem Ltx 300 Lcos Projector Instructions

Anthem Ltx 300 Lcos Projector Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Anthem Ltx 300 Lcos Projector Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 5 Anthem manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							  
    ENGLISH
    41
    Getting StartedPreparationBasic Operation Troubleshooting
    Settings Others
     Registering User-defi ned Picture Mode
    1
     
         
    Select the picture mode
       
    2  Adjust picture quality  
           ● See lChanging the initial setting of picture Mode zfor procedures 
                    on adjusting the picture quality.  (
    P40)
    3  To end
     Registering User-defi ned Picture Mode
    from the Menu
    1  Adjust picture quality
    ● See lChanging the Initial Setting of Picture Mode zfor procedures 
        on adjusting the picture quality.  (
    P40)
    2  Display the setting menu
    3  Select lPicture Adjustz  
            
    lPicture Modez  lNaturalz
          
           
    Register the setting
    ExitMENU BACKBack
    Select Operate
    6500K
    2
    Normal
    0
    0
    0
    0
    Picture ModeContrastBrightness
    Color Tint
    Color Temp.
    Gamma
    Advanced
    Lens Aperture
     Picture Adjust
    Natural
    Reset
    CinemaÎ CinemaÍ
    Dynamic 
    UserÍ
    UserÎ
    UserÏ
    Stage
    Natural
    ● Adjustment settings of image quality 
        will not be registered if other picture 
        mode is selected before registering 
        these settings.
    MENUMENU
    MENUMENU
      
      
       
        
       
       4
    ①Select
    ②Confirm
    USER2
    USER1 USER3
    CAUTION 
    						
    							5Troubleshooting
    42
     Troubleshooting
    ■ You do not need to worry about the following situations if there is no ab\
    normality on the screen.
      ● Part of the top surface or front of the unit is hot.
         
    ● A creaking sound is heard from the unit.
         
    ● An operating sound is heard from the inside of the unit.
         
    ● Color smear occurs on some screens.
    Power is not supplied
    Is the power cord disconnected?
    Insert the power cord (plug)  fi rmly.P24
    Is the lamp cover properly shut?Remove the power plug when the unit is in standby mode and 
    close the lamp cover properly. After that, insert the plug again.P47
    Is the lamp in Cool Down mode?After the Cool Down mode is complete, turn on the power 
    again.P25
    Projected image is dark
    Is the lamp near exhaustion?
    Check the lamp time on the information menu. Prepare a 
    new lamp unit or replace as soon as possible when the 
    lamp is near exhaustion.
    P46 to 48
    The unit works when power is turned on but stops abruptly after a few mi\
    nutes
    Are the air inlets and exhaust 
    vent blocked
    ?
    Remove the power plug when the unit is in standby mode and 
    remove any blocking object. After that, insert the plug again.P14 to 15
    Is the fi lter dirty?Clean the  fi lter.P49
    Video image does not appear
    Is the correct external input 
    selected?
    Select the correct external input.P24
    Is the AV device properly 
    connected?Connect the AV device properly.P18 to 21
    Is the power of the AV device turned 
    on?Turn on the power of the AV device and play the video.P24
    Are the correct signals being 
    output from the AV device?Set the AV device properly.P18 to 21
    Is the setting of the input terminal 
    correct?Set 
    lCOMP.
    z and 
    lHDMI
    z in the setting menu according to 
    the input signal.P33 -
    Is the video image temporarily 
    hidden?Press the [HIDE] button to display the video image again.P25
    Before sending the unit to your authorized dealer for repair, please check the following points.
    The following situations are not malfunctions.
    ■ Perform the following operations when the unit is unable to operate norm\
    ally due to external static or   
        noise.    
      
    ① When the unit is in standby mode, please pull out the power plug, then i\
    nsert again.
         ② Press the power button on the unit to turn on the power again.
    ■ A sound may be heard when the lamp is off but there is no danger.
    ■ LCOS device is manufactured using high-precision technology but there ma\
    y be some 
        missing pixels or pixels that remain permanently lit up.
    1112 
    						
    							  
    ENGLISH
    43
    Getting StartedPreparationBasic Operation Troubleshooting
    Settings Others
    The image cannot output by HDMI terminal
    Is the setup of 
    “Control with HDMIz 
    function 
    “Off”?Set up the “Control with HDMI z function to 
    lOff
    z.P33 - 11
    ●
     Even if the “Control with HDMI z function is “On”, there are still some devices cannot reveal imag\
    e normally.
    Color does not appear or looks strange
    Is the image correctly adjusted?
    Adjust 
    lColor
    z and 
    lTint
    z in the setting menu.P29 - 04  05
    Video image is fuzzy
    Is the focus correctly adjusted?
    Adjust the focus.P24
    Is the unit placed too near or too far away 
    from the screen? Set the unit at a correct distance from the screen.
    P22 to 23
    Video images are missing
    Has setting been performed for 
    screen mask?
    Set 
    lMask
    z in the setting menu to 
    lOff
    z.P27
    |35 - 19
    Is the display out of position?Alter the 
    lPicture Position
    z value in the setting menu to 
    ensure that images are not missing.P34 - 17
    Remote control does not work
    Are batteries installed correctly?
    Match the polarities ( or ) correctly when inserting 
    the batteries.P17
    Are batteries exhausted?Replace with new batteries.P17
    Is there an obstructive object 
    between the remote control and 
    remote sensor?
    Remove any obstructive objects.P17
    Is the remote control held too far 
    away from the unit?Hold the remote control closer to the sensor when 
    using.P17
    Power is cut off suddenly
    Has setting been performed for off 
    timer?
    Set  lOff Timer
    z in the setting menu to 
    lOff
    z.P38 - 34 
    						
    							5Troubleshooting
    44
     What to Do When these Messages 
    Are Displayed
    Message
    Cause (Details)
    No device is connected to the input terminal.
    The input terminal is connected but there is no signal.
         Input the video signals.
    A video signal that cannot be used in this unit has been input.
         Input video signals that can be used.
    * The names of input terminals such as COMP. will be displayed in yellow.
    This message is displayed when the accumulated lamp time has 
    exceeded 1900 hours.
    To clear the message, press the [Back] button.
         Get ready a new lamp unit and replace as soon as possible. Reset th\
    e  lamp time after replacing the lamp. (
    P46 to 48 )
    COMP.
    No  Input
    COMP.
    BACKBack
     Lamp  replacement 
    						
    							  
    ENGLISH
    45
    Getting StartedPreparationBasic Operation Troubleshooting
    Settings Others
     About Warning Indicators
    The accumulated lamp time or warning mode of this unit is displayed by t\
    he indicators.
    For information on indicator display during normal operation, see 
    lControls and Features
    z.
     (
    P14
    )
    No. Indicator
    Blinking
    Time Blinking
    Frequency Interval 
    between  Blinks ContentWARNING LAMP STANDBY
    ON
    1--Light on (Red)-- -During standby
    Indicator 
    display 
    in normal 
    conditions.
    2
    --Light on 
    (Green)-- -When the power on 
    (Hide Off)
    3
    --Blinking  (Green) 0.5 
    second continuous-When the power on 
    (Hide On)
    4
    --Blinking (Red) 0.5 
    second continuous-During cool down
    5
    -Light on
    (orange)----
    Lamp replacement is near (P46 to 48 )
    (When accumulated lamp time has 
    exceeded 1900 hours)
    6
    -Light on
    (orange)----
    Lamp has reached the end of life 
    (
    P46 to 48 )
    (When accumulated lamp time has 
    exceeded 2000 hours)
    7 Light on(Red) Blinking
    (orange)
    -
    0.25 
    second 1 time 0.75 
    second Lamp does not light up and unit is 
    unable to project
    8 0.25 
    second  2 times 0.75 
    second Lamp is turned off during projection
    9 0.25 
    second  3 times 0.75 
    second Lamp cover is removed
    10
    Blinking(Red)
    -
    -
    0.25 
    second 1 time 0.75 
    second Abnormalities in the power supply
    11 0.25 
    second  2 times 0.75 
    second Cooling fan stops
    (cooling fan gets caught)
    12 0.25 
    second  3 times 0.75 
    second
    Internal temperature is too high 
    (abnormal internal temperature)
    13 0.25 
    second  4 times 0.75 
    second External temperature is too high 
    (abnormal external temperature)
    14 0.25 
    second 1 time 0.75 
    second Abnormal electrical circuit 
    (abnormal startup of drive circuit)
    Blinking
    (orange)
    15
    0.25 
    second 2 times 0.75 
    second Abnormal electrical circuit 
    (abnormal communication of the 
    drive circuit)
    16 0.25 
    second  3 times 0.75 
    second Abnormal electrical circuit 
    (abnormal drive circuit of image)
    17 0.25 
    second  4 times 0.75 
    second Abnormalities in the automatic lens cover
       Actions to Be Taken for Warning Mode
    When the unit enters into warning mode (No. 7 to 17), it will automati\
    cally stop projection, and run the cooling 
    fan for about 60 seconds.
    After the cooling fan has stopped, pull out the power plug from the powe\
    r outlet.
    Then, follow the procedures below.
    No.
    Check Action
    7●
     Check that an impact shock has not occurred during operation.
    ● Check that the lamp unit and lamp cover are correctly installed.
    ● Check that nothing is blocking the auto lens cover. Turn on the power again.
    8
    9
    17
    10
    ●  Check that nothing is blocking the air inlets.
    ● Check that the external temperature is normal. Leave the unit until it cools down.
    After that, turn on the power again.
    11
    12
    13
    14
    15
    16
    If the warning indication is displayed again, please wait for the coolin\
    g fan stopped, then pull out the power plug from the power outlet. 
    Then call your authorized dealer for repair. 
    						
    							5Troubleshooting
    46
     Replacing the Lamp
    The lamp is a consumable item. If the image is dark or the lamp is turne\
    d off, replace the lamp unit.
    ● When the lamp replacement time approaches, a message is displayed on the\
     screen and the condition is indicated by the 
          indicator.  (
    P45)
      Remove the lamp cover
       ●  Remove the screws with a  screwdriver.
    Usable Lamp Life
    ●  The usable lamp life for this unit is 
         approximately  2000  hours.  The
        usable lamp life of 2000 hours is 
        merely the average usable life of
        lamps and we do not provide any 
         guarantee  for  this  fi gure.
    ●
     The lamp life may not reach 
         2000  hours  depending  on  the
          operating  conditions.
    ●  When the lamp has reached the 
          end  of  its  usable  life,  deterioration 
          progresses  rapidly.
    ●  If the image is dark or the color tone
          is  abnormal,  replace  the  lamp  unit 
         as soon as possible.
    ●  Setting Lamp Power to Standard 
    will help to prolong the lamp life.
    Purchasing the Lamp Unit
           Loosen the screws on the lamp unit
      ●
     Loosen the screws with a  screwdriver.
    Please consult your authorized dealer.
    ■ Lamp Unit
           Part  No.:  BHL5010-S
       Pull out the lamp unit
      ●
     Grasp the handle and pull out the lamp unit.
     Procedure for Lamp Replacement
    MEMO
     CAUTION
    ● Pull the power plug from the power 
          outlet.  Failure  to  do  so  may  cause 
          injuries  or  electric  shocks.
    ● Do not replace the lamp immediately 
          after  the  unit  has  been  used,  and 
          allow  a  cooling  period  of  1  hour 
         or more before replacement. The 
          temperature  of  the  lamp  is  still  high 
          and  this  may  cause  a  burn.
    ● Do not apply shock to the lamp unit. 
          It  may  cause  lamp  blowout.
    ● Do not use fl  ammable air duster to 
          clean  the  internal  parts  of  the  unit. 
          This  may  cause  fi re.
    1
    2
    3
    Handle 
    						
    							  
    ENGLISH
    47
    Getting StartedPreparationBasic Operation Troubleshooting
    Settings Others
    Install the new lamp unitCAUTION
    ● Use only genuine replacement parts  
           for  the  lamp  unit. Also,  never  attempt 
          to  reuse  an  old  lamp  unit.  This  may 
          cause  a  malfunction.
    ●  Do not touch the surface of a new lamp. 
          This may shorten the lamp life  and 
           cause lamp blowout.
    Tighten the screws of the new 
    lamp unit
    ●
     Tighten the screws with a  screwdriver.
    ● Do not place the removed lamp unit at 
            locations  that  is  reachable  by  children
            or  near  combustible  items 
    ●
     Dispose used lamp units in the same
          way  as  fl uorescent lamps
    Follow your
          local  community  rules  for  disposal.
    Attach the lamp cover
    ●  Insert the top part (with 2 claws) of the lamp cover into 
          the  unit.
    ●  Fasten the screws with a  screwdriver.
    MEMO
    4
    5
    6
    Handle
    After Replacing the Lamp 
    						
    							5Troubleshooting
    48
    Replacing the Lamp (Continued)
    BACK
    TEST
    HIDE
    BRIGHT
    CONTSHARP
    COLOR
    TINT
    N.R
    GAMMA
    C.TEMP
    INFO
    LENS.APASPECT
    LENS
    INPUT
    STANDBY
    ON
    MENU
    CINEMA1 CINEMA2
    NATURALSTAGEDYNAMIC
    USER1USER2
    USER3
    LIGHT
    After replacing the lamp, reset the lamp time.
       1  Insert the power plug to the power  
         outlet
     2  Must operate with the remote control 
        in the standby mode (the projector is 
        powered, but is not turned on).
         ● Press in the order as shown.
        
    ● Press each button within 2-second intervals and press the last 
                button for 2 seconds or more.
           ● [STANDBY/ON]  indicator and [LAMP] indicator blink alternately for 
     3 seconds. After that, the unit switches to standby mode.
    Resetting Lamp Time
    W   ARNING
    LAMP
    ST  ANDBY/ON
    ● Reset the lamp time only when you 
          have  replaced  the  lamp.
    ● Never reset the service time w hen
     
         the lamp is still in use. Otherwise, 
          the  approximate  standard  for  gauging 
          replacement  time  may  be  inaccurate   
          and lamp blowout may occur.
    Press for 2 seconds or more
    Light on (Red)
    HIDEHIDEBACKBACK
    CAUTION 
    						
    							  
    ENGLISH
    49
    Getting StartedPreparationBasic Operation Troubleshooting
    Settings Others
     Cleaning and Replacing the Filter
    Clean the fi lter regularly or air intake effi  ciency may deteriorate and malfunction may occur.
    Remove the inner fi lter                 CAUTION
                     
     
    ● Pull the power plug from the power  
        outlet.
                      MEMO 
    If the fi lter is damaged or too   
    dirty to be cleaned
                            
    ● 
    Wash the fi  lter with water and dry it in a shaded area.
    ● In extremely soiled cases, using a neutral detergent is recommended. 
           Put on rubber gloves when using a neutral detergent.
    ● After washing the fi
     lter with water, make sure that it is completely dry
          before reinstalling. Otherwise electric shock or malfunctions may occur.
    ●  Do not clean the fi  lter with a vacuum cleaner or air duster. The  fi lter is 
          soft and may be damaged.
    ● Replace with a new  fi lter. A dirty  fi lter  
          will dirty the internal parts of the unit 
          and  cause  shadows  on  the  video   
          image.
    ● To purchase a new  fi lter or when it 
          is  dirty  in  the  internal  parts,  consult 
          your  authorized  dealer.
    ■  Inner Filter Part No.:
         Replacement Filter: 
         the  appearance  is  black
         PB006560999  (Inner  Filter)
    Reinstall the inner  fi lter
                       
    1
    2
    3
    Lift up while pushing the claw
    Clean the fi  lter
    Check that the left 
    and right claws are 
    locked onto the unit 
    						
    							6Others
    50
     RS-232C Interface
    Control of this unit via a computer is possible by connecting the comput\
    er to this unit with a RS-232C 
    cross cable (D-Sub 9 pin).
      
    
     
    
     
    ● PC refers to the controller such as a personal computer.
                                                               
    D6D7D4D5D2D3D0D1
      Command Format
    The command between this unit and the computer consists of  lHeaderz, lUnit IDz, lCommand z, lDataz and lEndz.
    ● Header (1 byte), Unit ID (2 bytes), Command (2 bytes), Data (n by\
    tes), End (1 byte)
    ■
     Header
        This binary code indicates the start of communication.
    Binary code Type Description
    21Operating command PC
    →This unit
    3F  Reference  command PC
    →This unit
    40 Response command This unit
    →PC
    06 ACKThis unit
    →PC
    (When the command is accepted without error, it returns to 
    PC)
    ■
     Unit ID
          This  code  specifi  es the unit. The binary code is fi  xed at l8901z.
      RS-232C Specifi cations
    Pin No. SignalFunction Signal Direction
    2 RxDReceive data PC
    →This unit
    3 TxDTransmit data This unit
    →PC
    5 GNDSignal ground
    -
    1,4,6 - 9 N/C
    --
    ModeNon-synchronous
    Character Length8 bit
    ParityNone
    Start Bit1
    Stop Bit1
    Data rate19200 bps
    Data formatBinary
    T
    his unit
    Start Bit Stop Bit 
    						
    All Anthem manuals Comments (0)