    							Xenon/Granit User Guide 321
    Granit 1910i/1911i Scanner Guaranteed Performance 
    Granit 1980i/1981i Scanner Typical Performance (200 lux) 
    Focus Extended Range (ER)
    Symbology Near DistanceFar Distance
    5 mil Code 39 in. 3.8 7.2
    mm 96.5 182.9
    20 mil Code 39 in. 1 28.7
    mm 25.4 729
    100% UPC in. .6 21.7
    mm 15.2 551.2
    6.7 mil PDF417 in. 3 8.5
    mm 76.2 215.9
    10 mil Data Matrix in. 3.1 9.7
    mm 78.7 246.4
    20 mil QR Code in. .9 19.8
    mm 22.9 502.9
    Resolution (1D Code 39) 5 mil (.127mm)
    Resolution (2D Data Matrix) 7.5 mil (.191mm)
    Focus Full Range (FR)
    Symbology Near DistanceFar Distance
    7.5 mil Code 39 in. 3.9 64.9
    cm 10.0 164.9
    10 mil Code 39 in. 3.9 85.0
    cm 10.0 216.0
    20 mil Code 39 in. 6.0 171.1
    cm 15.2 434.5
    40 mil Code 39 in. 14.3 389.4
    cm 36.4 989.1
    55 mil Code 39 in. 20.6 521.0
    cm 52.2 1322.4
    100 mil Code 39 in. 40.7 more than 629.9
    cm 103.4 more than 1600.0
    100% UPC in. 4.8 90.5
    cm 12.2 229.8
    7.5 mil Data Matrix in. 3.9 29.9
    cm 10.0 75.9 
    						
    							322 Xenon/Granit User Guide
    Granit 1980i/1981i Scanner Guaranteed Performance (200 lux)
    10 mil Data Matrix in. 3.9 40.3
    cm 10.0 102.3
    55 mil Data Matrix in.  16.9 232.8
    cm 42.8 591.3
    100 mil Data Matrix in. 31.8 406.5
    cm 80.7 1032.5
    Resolution (1D Code 39) 2 mil (.051mm)
    Resolution (2D Data Matrix) 2 mil (.051mm)
    Focus  (Continued)Full Range (FR)
    Symbology  (Continued)Near DistanceFar Distance
    Focus Full Range (FR)
    Symbology Near DistanceFar Distance
    7.5 mil Code 39 in. 3.9 62.4
    cm 10.0 158.6
    10 mil Code 39 in. 3.9 82.1
    cm 10.0 208.6
    20 mil Code 39 in. 6.2 165.8
    cm 15.8 421.2
    40 mil Code 39 in. 15 371.7
    cm 38.1 944.1
    55 mil Code 39 in. 22.2 461.2
    cm 56.5 1171.4
    100 mil Code 39 in. 47.5 more than 629.9
    cm 120.7 more than 1600.0
    100% UPC in. 5.0 85.3
    cm 12.7 216.7
    7.5 mil Data Matrix in. 3.9 26.9
    cm 10.0 68.3
    10 mil Data Matrix in. 3.9 35.8
    cm 10.0 90.8
    55 mil Data Matrix in.  19.2 213.1
    cm 48.7 541.2
    100 mil Data Matrix in. 35.7 357.2
    cm 90.6 907.3
    Resolution (1D Code 39) 2 mil (.051mm)
    Resolution (2D Data Matrix) 2 mil (.051mm) 
    						
    							Xenon/Granit User Guide 323
    Granit 1920i Typical Performance 
    Granit 1920i Guaranteed Performance 
    Focus 
    Symbology Near DistanceFar Distance
    3 mil Code 39 in. 0 2.5
    mm 0 64
    5 mil Code 39 in. 0 3.5
    mm 0 89
    100% UPC in. 0 5.8
    mm 0 147
    5 mil PDF417 in. 0 2.6
    mm 0 66
    5 mil Data Matrix in. 0 1.5
    mm 0 39
    20 mil QR Code in. 0 6.4
    mm 0 162
    Resolution (1D Code 39) 2.5 mil (0.063mm)
    Resolution (2D Data Matrix) 4 mil (0.102mm)
    Focus 
    Symbology Near DistanceFar Distance
    3 mil Code 39 in. 0.2 2.2
    mm 5 55
    5 mil Code 39 in. 0 3.1
    mm 0 80
    100% UPC in. 0.39 5.2
    mm 10 133
    5 mil PDF417 in. 0 2.2
    mm 0 55
    5 mil Data Matrix in. 0.2 1.3
    mm 5 33
    20 mil QR Code in. 0.39 5.5
    mm 10 141
    Resolution (1D Code 39) 2.5 mil (0.063mm)
    Resolution (2D Data Matrix) 4 mil (0.102mm) 
    						
    							324 Xenon/Granit User Guide
    Standard Connector Pinouts
    Note:The following pin assignments are not compatible with Honeywell legacy products. 
    Use of a cable with improper pin assignments may lead to damage to the unit. Use of 
    any cables not provided by the manufacturer may result in damage not covered by 
    your warranty. 
    Keyboard Wedge
    10 Pin RJ41 Modular Plug - connects to the base
    Serial Output
    10 Pin RJ41 Modular Plug - connects to the base 
    1 Cable shield
    2Cable select
    3 Supply ground
    4 Terminal data
    5 Terminal clock
    6Keyboard clock
    7 +5V power
    8 Keyboard data
    9
    10
    1 Cable shield
    2Cable select
    3 Supply ground
    4 Transmit data
    5 Receive data - serial data to scanner
    6CTS
    7 +5V power
    8RTS
    9
    10 
    						
    							Xenon/Granit User Guide 325
    RS485 Output
    10 Pin RJ41 Modular Plug - connects to the base
    Note:RS485 signal conversion is performed in the cable. 
    USB
    10 Pin Modular Plug - connects to the base
    1 Cable shield
    2Cable select
    3 Supply ground
    4 Transmit data
    5 Receive data - serial data to scanner
    6
    7 +5V power
    8 Transmit Enable
    9
    10
    1 Cable shield
    2Cable select
    3 Supply ground
    4
    5
    6
    7 +5V power
    8
    9 Data +
    10 Data - 
    						
    							326 Xenon/Granit User Guide
    Required Safety Labels
    Xenon 1900/1902 Scanner
    Compliance 
    Label location Part 
    Number, 
    Serial Number 
    and Revision 
    Information
    location
    Illumination output
    LASER LIGHT- DO NOT STARE INTO BEAM  CLASS 2 LASER PRODUCT. REGARDER DANS LE FAISCEAU.  APPAREIL À LASER DE CLASSE 2. MAX. 1mW:
    630-680 nm 
    except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007.  IEC 60825-1:2007. Complies with 21 CFR 1040.10 and 1040.11 
    èfÂ.“#Øè]Z%ŽIƒ\%fÂ.“#Ø9îMØO©fÂ.“G±PèRAYONNEMENT LASER NE PAS 
    						
    							Xenon/Granit User Guide 327
    CCB01-010BT/CCB01-010BT-BF Base
    Part Number,
    Serial
    Number and 
    Revision 
    Information 
    location
    Compliance Label 
    locations 
    						
    							328 Xenon/Granit User Guide
    Granit 1910i/1911i/1920i/1980i/1981i Scanner
    Laser Label 
    location
    Illumination 
    output
    Part Number, Serial 
    Number and 
    Revision 
    Information locationCompliance 
    label location
    LASER LIGHT- DO NOT STARE INTO BEAM  CLASS 2 LASER PRODUCT. REGARDER DANS LE FAISCEAU.  APPAREIL À LASER DE CLASSE 2. MAX. 1mW:
    630-680 nm 
    except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007.  IEC 60825-1:2007. Complies with 21 CFR 1040.10 and 1040.11 
    èfÂ.“#Øè]Z%ŽIƒ\%fÂ.“#Ø9îMØO©fÂ.“G±PèRAYONNEMENT LASER NE PAS 
    						
    							Xenon/Granit User Guide 329
    CCB02-100BT/CCB05-100BT Base
    Compliance 
    Label locations 
    						
    All Honeywell manuals Comments (0)

    Related Manuals for Honeywell 1900gsr 2 User Manual