    							Displayingthecurrentsessioncookie
    Afterloggingin,youcanforcethebrowsertodisplaythecurrentsessioncookiebyentering
    javascript:alert(document.cookie)intheURLnavigationbar.Thefirstfieldvisibleis
    thesessionID.IfthesessionIDisthesameamongthedifferentbrowserwindows,thenthese
    windowsaresharingthesameiLO2session.
    YoucanforcethebrowsertorefreshandrevealyourtrueidentitybypressingtheF5key,selecting
    View>Refresh,orusingtherefreshbutton.
    Preventingcookie-relateduserissues
    Topreventcookie-basedbehavioralissues:
    •Startanewbrowserforeachloginbydouble-clickingthebrowsericonorshortcut.
    •ClicktheLogOutlinktoclosetheiLO2sessionbeforeclosingthebrowserwindow.
    InabilitytoaccessActiveXdownloads
    IfyournetworkdoesnotallowActiveXcontrolsyoucancapturetheDVC.DLLfromasinglesystem
    andthendistributethefiletoclientmachinesonthenetwork.
    1.LogintoiLO2.
    2.Enterhttps://ilo_name/dvc.cabinthebrowseraddressbar.
    3.Thefiledownloaddialogboxappears.ClickOpenandsavetheDVC.DLLfiletoyourlocal
    drive.
    4.CopytheDVC.DLLfiletotheclientsystemthatdoesnotallowActiveXdownloads.
    5.Fromthisclientsystem,openacommandpromptwindow.Navigatetothedirectorycontaining
    theDVC.DLLfileandenterregsvr32 dvc.dll.
    InabilitytogetSNMPinformationfromHPSIM
    TheagentsrunningonthemanagedserversupplySNMPinformationtoHPSIM.Foragentsto
    passinformationthroughiLO2,iLO2devicedriversmustbeinstalled.Forinstallationinstructions,
    see“InstallingiLO2devicedrivers”(page21).
    IfyouhaveinstalledthedriversandagentsforiLO2,verifythatiLO2andthemanagementPC
    areonthesamesubnet.YoucanverifythisquicklybypingingiLO2fromthemanagementPC.
    ConsultyournetworkadministratorforproperroutestoaccessthenetworkinterfaceofiLO2.
    Incorrecttimeordateoftheentriesintheeventlog
    YoucanupdatethetimeanddateoniLO2byrunningtheRBSU.Thisutilityautomaticallysetsthe
    timeanddateontheprocessorusingtheservertimeanddate.Thetimeanddatearealsoupdated
    byInsightManagementagentsonsupportednetworkoperatingsystems.
    InabilitytoupgradeiLO2firmware
    IfyouattempttoupgradetheiLO2firmwareanditdoesnotrespond,doesnotacceptthefirmware
    upgrade,oristerminatedbeforeasuccessfulupgrade,youcanuseoneofthefollowingoptions
    torestoreyouriLO2firmware.ConsulttheiLO2scriptingandcommand-lineresourceguidefor
    detailsonusingthescriptingcapabilitiesofiLO2.
    •Onlinefirmwareupdate–DownloadthiscomponentandrunitfromtheAdministratororroot
    contextofasupportedoperatingsystem.Thissoftwarerunsonthehostoperatingsystemand
    updatestheiLO2firmwarewithoutrequiringyoutolog-intoiLO2.
    •OfflinefirmwareupdateforSmartStartmaintenance–Downloadthecomponenttousewith
    theSmartStartfirmwaremaintenanceCDunderROMUpdateUtilityontheMaintenancetab.
    ThesecomponentscanalsobeusedwiththeHPDrivekeybootutility.
    Troubleshootingmiscellaneousissues201 
    						
    							•FirmwareMaintenanceCD-ROM–DownloadthecomponenttocreateabootableCD-ROM
    thatcontainsmanyfirmwareupdatesforProLiantserversandoptions.
    •ScriptingwithCPQLOCFG–DownloadCPQLOCFGcomponenttogetthenetwork-based
    scriptingutility,CPQLOCFG.CPQLOCFGenablesyoutouseRIBCLscriptsthatperform
    firmwareupdates,iLO2configuration,andiLO2operationsinbulk,securelyoverthenetwork.
    HPrecommendsthatLinuxusersreviewtheHPLights-OutXMLPERLscriptingsamplesforLinux.
    •ScriptingwithHPONCFG–DownloadtheHPONCFGcomponenttogetthehost-basedscripting
    utility,HPONCFG.ThisutilityenablesyoutouseRIBCLscriptsthatperformfirmwareupdates,
    andLOMprocessorconfigurationandoperationsinbulk,fromAdministratororrootaccount
    accessonsupportedhostoperatingsystems.
    •HPDirectoriesSupportforManagementProcessors–Downloadthecomponenttogetthe
    directorysupportcomponents.Oneofthecomponents,theHPLOMIG,canbeusedtodiscover
    iLO,iLO2,RILOE,andRILOEIIprocessorsandupdatethefirmware.Youdonothavetouse
    directoryintegrationtotakeadvantageofthisfunctionality.
    Diagnosticsteps
    Beforeattemptingaflashrecoveryofthefirmware,usethefollowingdiagnosticstepstoverifythat
    flashrecoveryisneeded:
    1.AttempttoconnecttoiLO2throughtheWebbrowser.Ifyouareunabletoconnect,thenthere
    isacommunicationissue.
    2.AttempttopingiLO2.Ifyouaresuccessful,thenthenetworkisworking.
    iLO2networkflashrecovery
    TheiLO2networkflashrecoverypayloadenablesyoutorecoverfromafailedfirmwareupgrade.
    TheflashrecoverypayloadusesFTP,whichcanonlybeusedwhentheflashrecoverypayloadis
    active,totransferthefirmwareimagetoiLO2.Theflashrecoverypayloadmustonlybeusedif:
    •Previousfirmwareupgradeattemptshavefailed
    •YouareunabletoconnecttotheWebbrowser
    IftheiLO2firmwareimageisdamaged,missing,orotherwisecorrupted,thentheiLO2flash
    recoveryprocessisusedtore-flashiLO2.Theflashrecoveryprocessisforthesolepurposeof
    gettingthesystemre-flashed.Nootherprocessescanrununtiltherecoveryprocessiscomplete.
    RecoveringfromabadiLO2flashimageusingnetworkflashrecovery
    PerformthefollowingstepstorecoverfromabadiLO2flashusingnetworkflashrecovery:
    1.OpenanFTPsessiontotheIPaddressorDNSnameofiLO2.
    2.LogintoiLO2usingthefixedusernameflash andthepasswordrecovery.
    Theusernameandpasswordarecase-sensitive.
    3.AttheFTPprompt,entertheputcommand,andthefilenameofthefirmwareimage.
    Thefollowingisanexampleoftheentriesusedfortheflashrecoveryprocess:
    ftp 192.168.177.142
    login: flash
    password: recovery
    put \iLO2_200.bin
    202TroubleshootingiLO2 
    						
    							Ifthefileisfound:
    •TheputcommandtransfersthefiletoiLO2
    •Theimagevalidates
    •Theflashprocessbegins
    Ifthefileisnotfound:
    •Someversionsoftheputcommanddonotdisplayanerrormessage
    NOTE:Ifthedirectorypathincludesspaces,enclosethepathandfilenameinquotes.
    Afterthefirmwareimagetransfers,therecoverypayloadcalculatesthechecksum,validatesthe
    digitalsignature,andreportsiftheimageisvalid.Theflashreprogrambeginsiftheimageisvalid,
    andtheflashprogressisreportedtotheclient.
    NOTE:Thisprocesstakesafewsecondswhiletherecoverypayloaddecryptsthestoredhash
    andcomputesahashfortheimagetocompareagainst.Iftheimageisvalid,theFTPserverbegins
    programmingtheimageintotheflashportion,andprovidesstatusupdates.
    Whencompleted,theflashrecoverypayloadmoduledisconnectsandrebootstheiLO2processor.
    Iftheflashrecoveryprocessisunsuccessful,starttheprocessagain,andwatchtheprogressfor
    anyerrors.Youmighthavetouseadifferentfirmwareimagefortheprocess.
    RecoveringfromabadiLO2flashimageusingtheHPSmartUpdateFirmwareDVD
    UsethefollowingproceduretorecoveriLO2fromabadflashupgradeusingthefirmwareDVD
    9.00,andiLO21.81:
    1.SettheiLO2SecurityOverrideSwitchonthesystemboardtoOn.Thelocationoftheswitch
    isprintedonalabellocatedontheinsideofthehoodcover.
    2.PowertheserveronandbootusingtheSmartUpdateFirmwareDVDversion9.00.TheISO
    imageisavailablefordownloadfromthefollowingwebsiteathttp://www.hp.com/go/
    foundation
    3.Atthebootmenu,selectInteractiveFirmwareUpdateversion9.00.
    4.AftertheSelectLanguagescreendisplays,enterthefollowingkeystrokestoexittheHPSmart
    UpdateManager:
    NOTE:AcommandpromptdisplaysontopoftheHPSmartUpdateManagerwindow(the
    commandprompttakesapproximately30secondstoappear).
    CTRL+ALT+d+b+x(pressandholdtheCTRL andALT keyswhiletypingd b x).
    5.Atthecommandprompt,navigatetotheSmartUpdateFirmwareDVDdirectorycontaining
    thesupplementaliLO2firmwareupdatebyusingthefollowingcommand:
    cd /mnt/cdrom/hp/swpackages
    6.TounloadtheHPILOmodule,enterthecommand:
    rmmod hpilo
    7.ToexecutetheiLO2firmwareupdateindirectmode,enterthecommand:
    sh CP012108.scexe --direct
    (thisparameterrequirestwodash(--)characters)
    8.AftertheiLO2firmwareupgradecompletes,powertheserveroffandsettheiLO2Security
    OverrideSwitchonthesystemboardtoOff.
    Troubleshootingmiscellaneousissues203 
    						
    							TheiLO2firmwaredoesnotrespondtoSSLrequests
    TheiLO2firmwaredoesnotrespondtoSSLrequestswhenaJavawarningappears.Ifauseris
    loggingintoaniLO2browserconnectionanddoesnotcompletetheloginprocessbyresponding
    totheJavacertificatewarning,iLO2doesnotrespondtofuturebrowserrequests.Theusermust
    continuetheloginprocesstofreetheiLO2Webserver.
    TestingSSL
    Thefollowingtestchecksforthecorrectsecuritydialogprompt.Anon-workingserverwillproceed
    toaPage cannot be displayedmessage.Ifthistestfails,yourdomaincontrollerisnot
    acceptingSSLconnections,andprobablyhasnotbeenissuedacertificate.
    1.OpenabrowserandnavigatetoCertificatesfolder.Right-clickthefolderandselectRequestNewCertificate.
    c.VerifyTypeisdomaincontrollerandclickNextuntilacertificateisused.
    YoucanalsouseMicrosoftLDPtooltoverifySSLconnections.FormoreinformationontheLDP
    tool,gototheMicrosoftwebsiteathttp://www.microsoft.com/support.
    AnoldcertificatecancauseissueswithSSLandonthedomaincontrollerwhenitpointstoa
    previouslytrustedCAwiththesamename,whichisrarebutmighthappenifacertificateservice
    isaddedandremovedandthenaddedagainonthedomaincontroller.Toremoveoldcertificates
    andissueanewonefollowtheinstructionsaboveinstep2.
    ResettingiLO2
    Inrareinstances,itmightbenecessarytoresetiLO2;forexample,ifiLO2isnotrespondingto
    thebrowser.ToresetiLO2,youmustpowerdowntheserveranddisconnectthepowersupplies
    completely.
    TheiLO2firmwaremightresetitselfincertaininstances.Forexample,aninternaliLO2watchdog
    timerresetsifthefirmwaredetectsaniLO2issue.Ifafirmwareupgradeiscompletedoranetwork
    settingischanged,iLO2alsoresets.
    TheHPInsightManagementAgents5.40andlaterhavetheabilitytoresetiLO2.ToresetiLO2,
    chooseoneofthefollowingoptions:
    •SelecttheResetiLO2optionontheHPManagementAgentwebpageundertheiLO2section.
    •ClickApplyontheNetworkSettingspagetomanuallyforcetheiLO2managementprocessor
    toreset.YoudonotneedtochangeanyparametersbeforeclickingApply.
    •ClickResetontheDiagnosticpageoftheiLO2browserinterface.
    ServernamestillpresentafterERASEutilityisexecuted
    TheServerNamefieldiscommunicatedtoiLO2throughtheInsightManagerAgents.
    204TroubleshootingiLO2 
    						
    							ToremovetheServerNamefieldafteraredeploymentofaserver,dooneofthefollowing:
    •LoadtheInsightManagerAgentstoupdatetheServerNamefieldwiththenewservername.
    •UsetheResettoFactoryDefaultsfeatureoftheiLO2RBSUutilitytocleartheServerName
    field.
    ThisprocedureclearsalliLO2configurationinformation,notjusttheServerNameinformation.
    •ChangetheservernameontheAdministration>Access>OptionspageontheiLO2browser
    interface.
    Troubleshootingaremotehost
    Troubleshootingaremotehostservermightrequirerestartingtheremotesystem.Youcanrestart
    theremotehostserverbyusingtheoptionslistedintheVirtualDevicestab.
    Troubleshootingmiscellaneousissues205 
    						
    							8Technicalsupport
    Supportinformation
    HPiLOAdvancedPackandHPiLOAdvancedPackforBladeSystemincludedwithInsightControl
    suitesandiLOPowerManagementPackincludeoneyearof24x7HPSoftwareTechnicalSupport
    andUpdateService.ThisserviceprovidesaccesstoHPtechnicalresourcesforhelpinresolving
    softwareimplementationoroperationsissues.Theservicealsoprovidesaccesstosoftwareupdates
    andreferencemanualseitherinelectronicformoronphysicalmediaastheyaremadeavailable
    fromHP.
    HPoffersproductsupportandproductupdatestoHPiLOAdvancedandHPiLOAdvancedPack
    forBladeSystemcustomersintwoways:
    •Whenpurchasedasindividuallicenses,youreceivestartuptechnicalsoftwaresupportatno
    additionalchargebycallingHPSupportupto90daysfromthedateofpurchase.Phone
    supportisoffered,assistingyouwithinstallation,setup,andquestionspertainingtothecanned
    scriptsandtherespectiveusages.HPworldwidenumbersforSupportareavailableonthe
    HPwebsite(http://www.hp.com/country/us/en/support.html).Youcanpurchaseupdates
    separatelyatyourdiscretion.
    •WhenHPiLOAdvancedPackandHPiLOAdvancedPackforBladeSystemareobtained
    withthepurchaseofanInsightControlsuiteandiLOPowerManagementPack,licenses
    includeoneyearof24x7HPSoftwareTechnicalSupportandUpdateService.
    WiththebundledTechnicalSupportandUpdateService,HPiLOAdvancedPackandHPiLO
    AdvancedPackforBladeSystemcustomersbenefitfromexpeditedissueresolution,and
    proactivenotificationanddeliveryofiLOAdvancedandiLOSelectsoftwareupdates.For
    moreinformation,seetheHPwebsiteathttp://www.hp.com/go/ilo,selectyourproduct,
    andreviewtheQuickspecs.
    ToactivateyourHPSoftwareTechnicalSupportandUpdateServiceforiLOAdvancedand
    iLOSelect,youmustregisteryoursoftwarepurchasethroughtheHPwebsiteathttp://
    www.hp.com/go/ilo.Failuretoregisteryourservicejeopardizesservicefulfillment.
    YourServiceAgreementIdentifier(SAID)isdeliveredtoyouafterregistration.Afteryoureceive
    yourSAID,youcangototheSoftwareUpdateManager(SUM)webpagetoviewyour
    contractandchooseelectronicdelivery(inadditiontostandardmedia-basedupdates).For
    moreinformationaboutthisservice,seetheHPwebsiteathttp://www.hp.com/services/
    insight.
    HPalsooffersanumberofadditionalsoftwaresupportservices.Manyareprovidedatnoadditional
    charge.
    •Startuptechnicalsoftwaresupport–Phonesupportisavailabletohelpyouwithbasic
    installation,setup,andusagequestions.ThissupportisprovidedbytheknowledgeableHP
    InsightControlManagementandSystemsInsightManagerspecialists'teamandisavailable
    atnoadditionalchargeupto90daysfromthedateofpurchaseofyourserver.Forsupport
    intheUS,call
    •18003345144.Whenprompted,askforInsightManager,P2P,orSMP.
    HPworldwidesupportnumbersareavailableattheHPwebsiteathttp://www.hp.com/go/
    assistance'.
    •JointhediscussionontheHPwebsiteathttp://forums.itrc.hp.com.TheHPSupportForumis
    acommunity-based,user-supportedtooldesignedsothatHPcustomerscandiscussHPproducts.
    TodiscussInsightControlandInsightEssentialssoftware,clickManagementSoftwareand
    SystemTools.
    206Technicalsupport 
    						
    							•SoftwareandDriversdownloadpagesareontheHPwebsiteathttp://www.hp.com/support.
    ThesepagesprovidethelatestsoftwareanddriversforyourProLiantproducts.
    •ManagementSecurityisontheHPwebsiteathttp://www.hp.com/servers/manage.HPis
    proactiveinitsapproachtothequalityandsecurityofallitsmanagementsoftware.Besure
    tocheckthiswebsiteoftenforthelatestdownloadablesecurityupdates.
    •ObtainthelatestSmartStartfirmwareontheHPwebsiteathttp://www.hp.com/servers/
    smartstart.YoucandownloadtheSmartStart,Management,andFirmwareCDsbyfollowing
    asimpleregistrationprocessfromtheSmartStartwebsite.Toreceivephysicalkitswitheach
    release,youcanordersinglereleasekitsfromtheSmartStartwebsite.Toreceiveproactive
    notificationwhenSmartStartreleasesareavailable,subscribetoSubscriber'sChoicetheHP
    websiteathttp://www.hp.com/go/subscriberschoice.
    HPcontactinformation
    ForthenameofthenearestHPauthorizedreseller:
    •SeetheContactHPworldwide(inEnglish)webpageathttp://www.hp.com/go/assistance'.
    ForHPtechnicalsupport:
    •ToobtainHPcontactinformationforanycountry,seetheContactHPworldwidewebsiteat
    http://www.hp.com/go/assistance'.
    TocontactHPbyphone:
    ◦Call18003345144.Thisserviceisavailable24hoursaday,7daysaweek.For
    continuousqualityimprovement,callsmayberecordedormonitored.
    ◦IfyouhavepurchasedaCarePack(serviceupgrade),call1-800-633-3600.Formore
    informationaboutCarePacks,seetheHPwebsiteathttp://www.hp.com/hps.
    BeforeyoucontactHP
    BesuretohavethefollowinginformationavailablebeforeyoucallHP:
    •Technicalsupportregistrationnumber(ifapplicable)
    •Productserialnumber
    •Productmodelnameandnumber
    •Productidentificationnumber
    •Applicableerrormessages
    •Add-onboardsorhardware
    •Third-partyhardwareorsoftware
    •Operatingsystemtypeandrevisionlevel
    HPcontactinformation207 
    						
    							Acronymsandabbreviations
    ACPIAdvancedConfigurationandPowerInterface
    ARPAddressResolutionProtocol
    ASCIIAmericanStandardCodeforInformationInterchange
    ASMAdvancedServerManagement
    ASRAutomaticServerRecovery
    BMCbaseboardmanagementcontroller
    CAcertificateauthority
    CLICommandLineInterface
    CLPcommandlineprotocol
    CRCertificateRequest
    CRLcertificaterevocationlist
    DAVDistributedAuthoringandVersioning
    DDNSDynamicDomainNameSystem
    DHCPDynamicHostConfigurationProtocol
    DLLdynamiclinklibrary
    DMTFDistributedManagementTaskForce
    DNSdomainnamesystem
    DVODigitalVideoOut
    EAASEnvironmentAbnormalityAuto-Shutdown
    EBIPAEnclosureBayIPAddressing
    EMSEmergencyManagementServices
    EULAenduserlicenseagreement
    FEHfatalexceptionhandler
    GNOMEGNUNetworkObjectModelEnvironment
    GUIgraphicaluserinterface
    HBheartbeat
    HEMHighEfficiencyMode
    HIDhumaninterfacedevice
    HPSIMHPSystemsInsightManager
    HPONCFGHPLights-OutOnlineConfigurationutility
    HPQLOMGCHPLights-OutMigrationCommandLine
    HPQLOMIGHPLights-OutMigration
    ICMPInternetControlMessageProtocol
    iLOIntegratedLights-Out
    iLO2IntegratedLights-Out2
    IMLIntegratedManagementLog
    IPInternetProtocol
    IPMIIntelligentPlatformManagementInterface
    IRCIntegratedRemoteConsole
    IRQinterruptrequest
    JVMJavaVirtualMachine
    KCSKeyboardControllerStyle
    208Acronymsandabbreviations 
    						
    							KDEKDesktopEnvironment(forLinux)
    KVMkeyboard,video,andmouse
    LANlocal-areanetwork
    LDAPLightweightDirectoryAccessProtocol
    LEDlight-emittingdiode
    LOMLights-OutManagement
    LSBleastsignificantbit
    MACMediaAccessControl
    MLAMasterLicenseAgreement
    MMCMicrosoftManagementConsole
    MPMultilinkPoint-to-PointProtocol
    MTUmaximumtransmissionunit
    NICnetworkinterfacecontroller
    NMInon-maskableinterrupt
    NVRAMnon-volatilememory
    PERLPracticalExtractionandReportLanguage
    PKCSPublic-KeyCryptographyStandards
    POSTPower-OnSelfTest
    PSPProLiantSupportPack
    RASremoteaccessservice
    RBSUROM-BasedSetupUtility
    RDPRemoteDesktopProtocol
    RIBRemoteInsightBoard
    RIBCLRemoteInsightBoardCommandLanguage
    RILOERemoteInsightLights-OutEdition
    RILOEIIRemoteInsightLights-OutEditionII
    ROMread-onlymemory
    RSARivest,Shamir,andAdelmanpublicencryptionkey
    RSMRemoteServerManagement
    SAIDServiceAgreementIdentifier
    SBIPCStaticBayIPConfiguration
    SLESSUSELinuxEnterpriseServer
    SMASHSystemManagementArchitectureforServerHardware
    SNMPSimpleNetworkManagementProtocol
    SSHSecureShell
    SSLSecureSocketsLayer
    SSOsinglesign-on
    SUMsoftwareupdatemanager
    SUVserial,USB,video
    TCPTransmissionControlProtocol
    TPMtrustedplatformmodule
    UARTuniversalasynchronousreceiver-transmitter
    UIDunitidentification
    USBuniversalserialbus
    VMVirtualMachine
    209 
    						
    							VPNvirtualprivatenetworking
    VRMvoltageregulatormodule
    WINSWindowsInternetNamingService
    WSwebservices
    XMLextensiblemarkuplanguage
    210Acronymsandabbreviations 
    						
    All HP manuals Comments (0)

    Related Manuals for HP Ilo 2 User Guide