Have a look at the manual Panasonic High Speed Color Scanner Kvs7065c Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

Cleaning the Unit 31 5Close the exit door. ≥When you close the exit door, close it securely until it is locked. ∫Cleaning the reference plates and ADF glasses 1Turn off the scanner. 2Pull the exit door release to open the exit door. 3Clean the ADF glass (F) and reference plate (B) with the roller cleaning paper (KV-SS03). 4Clean the ADF glass (B) and reference plate (F) with the roller cleaning paper (KV-SS03). 5Close the exit door. ≥When you close the exit door, close it securely until it is locked. Reference plate (B) ADF glass (F) Reference plate (F) ADF glass (B)

Cleaning the Unit 32 ∫Cleaning the paper and waiting sensors, double feed detector How to clean sensors (detectors) and reflectors. Remove the brush from the accessory blower and blow off the dirt with the blower. 1Turn off the scanner. 2Push the ADF door release to open the ADF door. 3Blow off the dirt on the surface of the paper sensor and waiting sensor with an accessory blower. 4And also blow off the dirt on the surface of the reflector sheet for the waiting sensor with the accessory blower. 5Blow off the dirt from the double feed detector (G) and double feed detector (R) with the accessory blower. 6Close the ADF door. ≥When you close the ADF door, close it securely until it is locked. Blower Sensor or detector Waiting sensor Reflector sheet for waiting sensor Paper sensor Double feed detector (G) Double feed detector (R)

Cleaning the Unit 33 ∫Cleaning the starting, skew and ending sensors How to clean sensors (detectors) and reflectors. Remove the brush from the accessory blower and blow off the dirt with the blower. 1Turn off the scanner. 2Pull the exit door release to open the exit door. 3Blow off the dirt on the surface of the starting, skew (L), skew (R), and ending sensors with the accessory blower. 4And blow off the dirt from the reflector sheets for the starting, skew (L), skew (R), and ending sensors with the blower. 5Close the exit door. ≥When you close the exit door, close it securely until it is locked. Blower Sensor or detector Ending sensor Skew (L) sensor Skew (R) sensor Starting sensor Reflector sheet for skew (R) sensor Reflector sheet for starting sensor Reflector sheet for skew (L) sensor Reflector sheet for ending sensor

Cleaning the Unit 34 ∫Cleaning the flatbed glass and document cover detector 1Turn off the scanner. 2Fold the hopper tray in the direction of the arrow. 3Open the document cover. 4Clean up the surface of flatbed glass with the roller cleaning paper (KV- SS03) to remove the dirt. (Also clean up the surface of the flatbed sheet, as required.) 5Blow off the dirt from the document cover detector. 6Close the document cover and put back the hopper tray to the original position. How to clean sensors (detectors) and reflectors. Remove the brush from the accessory blower and blow off the dirt with the blower. Hopper trayDocument cover Flatbed sheet Flatbed glass Document cover detector Blower Sensor or detector

35 Replacing Consumable Roller Modules ∫Replacing paper feed roller modules Recommended change : 300,000 scans 1Turn the power off. 2Push the ADF door release to open the ADF door. 3Pull down the paper feed roller module in the direction of the arrow. 4Remove the paper feed roller module as shown on the figure. 5Open the optional roller exchange kit (KV-SS015), and take out the new paper feed roller module. ADF door ADF door release

Replacing Consumable Roller Modules 36 6Install the new paper feed roller module. 7Push up the new paper feed roller module in the direction of the arrow, so that it is locked by the magnets on both sides. 8Close the ADF door. ≥When you close the ADF door, close it securely until it is locked.

Replacing Consumable Roller Modules 37 ∫Replacing Retard Roller 1Turn the power off. 2Push the ADF door release to open the ADF door. 3Open the retard cover in the direction of the arrow shown in the figure by using the indent on the back side. 4Remove the retard roller, pulling up the shaft in the direction of the arrow. 5Take out the new retard roller in the optional roller exchange kit (KV- SS015). ADF door ADF door release Retard roller Retard coverIndent

Replacing Consumable Roller Modules 38 6Install the new retard roller by matching the groove of its shaft with the groove of the metal holder. 7Close the retard cover. 8Close the ADF door. ≥When you close the ADF door, close it securely until it is locked. 9Clear the roller replacing counter with User Utility. ≥Click [Clear Counter] button for [After Replace Roller] with User Utility. Groove

39 Shading Adjustment ¥What is the purpose of the shading adjustment? The process whereby the variations in the distribution of the lamp’s light quantity are transformed into a fixed output within the scanning range is known as shading adjustment. It can be carried out by means of the User Utility using the special shading paper which is provided with this scanner. ¥When shading adjustment is required Proceed with the compensation when the colors in some parts of the scanned images differ in the extreme, or when the image quality fails to be improved even after the inside the scanner is cleaned. ¥Before proceeding with the shading adjustment Before proceeding, be absolutely sure to thoroughly clean the ADF glass (F) area, ADF glass (B) area, reference plate (F) and reference plate (B) as well as the transport path and drive rollers of the scanning unit. If the shading adjustment is carried out while these par ts are still dirty, it will not be possible to eliminate the lines that form on the scanned images. ¥Shading adjustment procedure 1. Start the User Utility. 2. Click “User Shading” on the main menu, and operate as the image display dictates. For further details, refer to section 4.6 in the User Utility Reference Manual. ¥Caution If the scanned images are still lined after the shading adjustment has been performed and if these lines are not elim- inated even after the ADF glass areas have been cleaned, it means that the shading has not been compensated properly. Clean the parts again, and then proceed with the shading adjustment.

40 Repacking Instructions It is highly recommended that you keep the original carton and ALL packing materials. If you need to transport or ship your scanner, please follow these instructions: ≥Use the original carton and all of the original packing materials. ≥Improper repacking of the scanner may result in a service charge to repair the unit. ≥The scanner should be handled in the correct (horizontal) position. Materials Required: ≥Original scanner carton & packing materials ≥Shipping tape and scissors 1Turn the power switch off and disconnect your scanner from the electrical outlet and the interface cable. 2Remove the hopper tray and attach the protective sheets with tapes. 3Pack the scanner. Power cordUSB2.0 cable CD-ROM (Operating instructions) (Driver software) Installation manual Maintenance manual Roller cleaning paper (3 pieces) Shading chart Blower Hopper tray