Page 201

NDA-24298 CHAPTER 4
Page 167
Issue 1
ASYD : Assignment of System Data
SYSTEM
DATA
TYPE
(SYS)TENANT
NUMBERSYSTEM
DATA
INDEX
(INDEX)
1 - 15DATA
(DATA)
00 - FF
(Hex)BIT 
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1BIT
214
b0CW Lamp on Attendant Console - Threshold CW Lamp flashes 
when the number of Calls Waiting is greater than or equal to 
this data.
b3b2b1b0b3b2b1b0
0 000=No flash1000=8 calls
0 001=1 call 1001=9 calls
0 010=2 calls 1010=10 calls
0 011=3 calls 1011=11 calls
0 100=4 calls 1100=12...

Page 202

CHAPTER 4 NDA-24298
Page 168
Issue 1
ASYD : Assignment of System Data 
Note:
When the numbering plans within the CCIS Network are unified, assign “0” to this data; otherwise assign
“1.”
SYSTEM
DATA
TYPE
(SYS)TENANT
NUMBER
(TN)
1 - 63SYSTEM 
DATA
INDEX
(INDEX)
0 - 15DATA
(DATA)
00 - FF
(Hex)BIT
CORRESPONDING
DATASYSTEM DATA CONTENTS
DATA
0/1BIT
2150
b0Not used
0
b1Attendant Overflow Service
0/1 = No/Yes
0
b2Not used
b3
Destination restriction for an outgoing trunk call originated 
by Passing Dial Tone...

Page 203

NDA-24298 CHAPTER 4
Page 169
Issue 1
ASYD : Assignment of System Data
SYSTEM
DATA
TYPE
(SYS)SYSTEM
DATA
INDEX
(INDEX)
0 - 31DATA
(DATA)
00 - FF
(Hex)BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1BIT
30
b0
ON Time is to be assigned a value from 
1 Hex to F Hex (1~15). (Unit of Time is 
Second.)Timer Value for Ringer 
used for Incoming Trunk 
Calls (Ringer Pattern 0)
Note:Normally, this 
Index is assigned 
data 21 Hex. 
(1 sec.-ON, 
2 sec.-OFF)b1
b2
b3
b4
OFF Time is to be assigned a value 
from 1...

Page 204

CHAPTER 4 NDA-24298
Page 170
Issue 1
ASYD : Assignment of System Data 
33
b0
2 Burst (0.4 sec.–ON, 0.2 sec.-OFF, 0.4 sec.–ON) on the ON Time for 
Ringer Pattern 0
0/1 = Not Required/Required
b1
2 Burst (0.4 sec.–ON, 0.2 sec.–OFF, 0.4 sec.–ON) on the ON Time 
for Ringer Pattern 1
0/1 = Not Required/Required
0
b2
Not used 0b3
0b4
b5
3 Burst (0.4 sec.–ON, 0.2 sec.–OFF, 0.8 sec.–ON, 0.2 sec.–OFF, 0.4 
sec.-ON) on the ON Time for Ringer Pattern 5
0/1 = Not Required/Required
0
b6Not used
0
b7Allow Bit 0 to be...

Page 205

NDA-24298 CHAPTER 4
Page 171
Issue 1
ASYD : Assignment of System Data
311
b0
PBST: PB signal (DTMF) timer for Dterm and desk console.
This data is to be assigned from 0 Hex to F Hex (0~15).
Timer Value setting is (PBST + 1) 
× 128 msec.
b1
b2
b3
0b4
Not used 0b5
0b6
0b7
12
b0
ON Time is to be assigned a value from 
1 Hex to F Hex (1~15). (Unit of Time is 
Seconds.)Timer Value for Data 
Communication RS-232C 
CI (Call Indicator; same as 
RI: Ring Indicator) Signal
Note: When this data is 
00 Hex, Default...

Page 206

CHAPTER 4 NDA-24298
Page 172
Issue 1
ASYD : Assignment of System Data 
328 00 Not used
29 00 Not used
30 00 Not used
31 00 Not used
SYSTEM
DATA
TYPE
(SYS)SYSTEM
DATA
INDEX
(INDEX)
0 - 31DATA
(DATA)
00 - FF
(Hex)BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1BIT 

Page 207

NDA-24298 CHAPTER 4
Page 173
Issue 1
ASYDL : Assignment of System Data into Local DM (LDM)
ASYDL: Assignment of System Data into Local DM (LDM)
SYSTEM
DATA
TYPE
(SYS)SYSTEM
DATA
INDEX
(INDEX)
512 - 1535DATA
(DATA)
00 - FF
(Hex)BIT 
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1BIT
1512
b0
Fusion Point Code (FPC) of self node in hexadecimal.
FPC 1-253 (01 Hex-FD Hex)
Note:After assigning/changing the FPC, System
Initialization (Non-Load Initialization) is
required. Assign only for Fusion Network.
b1
b2...

Page 208

CHAPTER 4 NDA-24298
Page 174
Issue 1
ASYDL : Assignment of System Data into Local DM (LDM)
1515 IP Address (Hex) for PBX over External LAN
Note:This data is valid when the PBX is connected
to the external PC.
When default IP address (172. 16. 253. 0) for the PBX 
is used, this data setting is not necessary.
Example:IP Address: 133. 206. 8. 1 516
517
518
519 Subnet Mask (Hex) for PBX over External LAN
Note:This data is valid when the PBX is connected
to the external PC.
When default IP address (172. 16....

Page 209

NDA-24298 CHAPTER 4
Page 175
Issue 1
ASYDL : Assignment of System Data into Local DM (LDM)
1523
Default Gateway Address of External LAN 
Gateway Address (IP address of Router) of Network 
connecting PBX.
Note:This data is valid when the PBX is connected
to the external PC LAN.
In the case of no Network Gateway,
assignment data is 00 Hex. in Index 523
through 526.
Example:Default Gateway Address:
 133. 206. 8. 254
524
525
526
527
b0 ~ b3
Designate the maximum number of the tandem node 
for Fusion...

Page 210

CHAPTER 4 NDA-24298
Page 176
Issue 1
ASYDL : Assignment of System Data into Local DM (LDM)
1528
b0Voice Recognition Services Timer
MTC = 0 - 15 (0h to Fh) seconds
Timer value = MTC × TC
This timer defaults to 30 seconds when 00h is 
assigned.
b1
b2
b3
b4Timer Class (TC)
b6b5b4b6b5b4b6b5b4
0 0 0= -----011=2 sec.110=-----
0 0 1 1 00 =30 sec.111=-----
0 1 0= -----101=------
b5
b6
b7
529
b0Parity Check Method for SMDR/MCI with LAN 
Interface
b0b1
0 0 = Non-Parity Check
1 0 = Odd Parity Check
0 1 = Even...
Start reading NEC Neax 2400 Ipx Office Data Specification