Page 201
NDA-24298 CHAPTER 4 Page 167 Issue 1 ASYD : Assignment of System Data SYSTEM DATA TYPE (SYS)TENANT NUMBERSYSTEM DATA INDEX (INDEX) 1 - 15DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT 214 b0CW Lamp on Attendant Console - Threshold CW Lamp flashes when the number of Calls Waiting is greater than or equal to this data. b3b2b1b0b3b2b1b0 0 000=No flash1000=8 calls 0 001=1 call 1001=9 calls 0 010=2 calls 1010=10 calls 0 011=3 calls 1011=11 calls 0 100=4 calls 1100=12...
Page 202
CHAPTER 4 NDA-24298 Page 168 Issue 1 ASYD : Assignment of System Data Note: When the numbering plans within the CCIS Network are unified, assign “0” to this data; otherwise assign “1.” SYSTEM DATA TYPE (SYS)TENANT NUMBER (TN) 1 - 63SYSTEM DATA INDEX (INDEX) 0 - 15DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATASYSTEM DATA CONTENTS DATA 0/1BIT 2150 b0Not used 0 b1Attendant Overflow Service 0/1 = No/Yes 0 b2Not used b3 Destination restriction for an outgoing trunk call originated by Passing Dial Tone...
Page 203
NDA-24298 CHAPTER 4 Page 169 Issue 1 ASYD : Assignment of System Data SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 31DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT 30 b0 ON Time is to be assigned a value from 1 Hex to F Hex (1~15). (Unit of Time is Second.)Timer Value for Ringer used for Incoming Trunk Calls (Ringer Pattern 0) Note:Normally, this Index is assigned data 21 Hex. (1 sec.-ON, 2 sec.-OFF)b1 b2 b3 b4 OFF Time is to be assigned a value from 1...
Page 204
CHAPTER 4 NDA-24298 Page 170 Issue 1 ASYD : Assignment of System Data 33 b0 2 Burst (0.4 sec.–ON, 0.2 sec.-OFF, 0.4 sec.–ON) on the ON Time for Ringer Pattern 0 0/1 = Not Required/Required b1 2 Burst (0.4 sec.–ON, 0.2 sec.–OFF, 0.4 sec.–ON) on the ON Time for Ringer Pattern 1 0/1 = Not Required/Required 0 b2 Not used 0b3 0b4 b5 3 Burst (0.4 sec.–ON, 0.2 sec.–OFF, 0.8 sec.–ON, 0.2 sec.–OFF, 0.4 sec.-ON) on the ON Time for Ringer Pattern 5 0/1 = Not Required/Required 0 b6Not used 0 b7Allow Bit 0 to be...
Page 205
NDA-24298 CHAPTER 4 Page 171 Issue 1 ASYD : Assignment of System Data 311 b0 PBST: PB signal (DTMF) timer for Dterm and desk console. This data is to be assigned from 0 Hex to F Hex (0~15). Timer Value setting is (PBST + 1) × 128 msec. b1 b2 b3 0b4 Not used 0b5 0b6 0b7 12 b0 ON Time is to be assigned a value from 1 Hex to F Hex (1~15). (Unit of Time is Seconds.)Timer Value for Data Communication RS-232C CI (Call Indicator; same as RI: Ring Indicator) Signal Note: When this data is 00 Hex, Default...
Page 206
CHAPTER 4 NDA-24298 Page 172 Issue 1 ASYD : Assignment of System Data 328 00 Not used 29 00 Not used 30 00 Not used 31 00 Not used SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 31DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT
Page 207
NDA-24298 CHAPTER 4 Page 173 Issue 1 ASYDL : Assignment of System Data into Local DM (LDM) ASYDL: Assignment of System Data into Local DM (LDM) SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 512 - 1535DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT 1512 b0 Fusion Point Code (FPC) of self node in hexadecimal. FPC 1-253 (01 Hex-FD Hex) Note:After assigning/changing the FPC, System Initialization (Non-Load Initialization) is required. Assign only for Fusion Network. b1 b2...
Page 208
CHAPTER 4 NDA-24298 Page 174 Issue 1 ASYDL : Assignment of System Data into Local DM (LDM) 1515 IP Address (Hex) for PBX over External LAN Note:This data is valid when the PBX is connected to the external PC. When default IP address (172. 16. 253. 0) for the PBX is used, this data setting is not necessary. Example:IP Address: 133. 206. 8. 1 516 517 518 519 Subnet Mask (Hex) for PBX over External LAN Note:This data is valid when the PBX is connected to the external PC. When default IP address (172. 16....
Page 209
NDA-24298 CHAPTER 4 Page 175 Issue 1 ASYDL : Assignment of System Data into Local DM (LDM) 1523 Default Gateway Address of External LAN Gateway Address (IP address of Router) of Network connecting PBX. Note:This data is valid when the PBX is connected to the external PC LAN. In the case of no Network Gateway, assignment data is 00 Hex. in Index 523 through 526. Example:Default Gateway Address: 133. 206. 8. 254 524 525 526 527 b0 ~ b3 Designate the maximum number of the tandem node for Fusion...
Page 210
CHAPTER 4 NDA-24298 Page 176 Issue 1 ASYDL : Assignment of System Data into Local DM (LDM) 1528 b0Voice Recognition Services Timer MTC = 0 - 15 (0h to Fh) seconds Timer value = MTC × TC This timer defaults to 30 seconds when 00h is assigned. b1 b2 b3 b4Timer Class (TC) b6b5b4b6b5b4b6b5b4 0 0 0= -----011=2 sec.110=----- 0 0 1 1 00 =30 sec.111=----- 0 1 0= -----101=------ b5 b6 b7 529 b0Parity Check Method for SMDR/MCI with LAN Interface b0b1 0 0 = Non-Parity Check 1 0 = Odd Parity Check 0 1 = Even...