Home > NEC > Communications System > NEC Neax 2400 Ipx Office Data Specification

NEC Neax 2400 Ipx Office Data Specification

Here you can view all the pages of manual NEC Neax 2400 Ipx Office Data Specification. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 571

NDA-24298 CHAPTER 4
Page 537
Issue 1
ARTDN : Assignment of Route Class Data for NDM
6TCLTrunk Class
Specify the kind of trunk
  1 = DDD Line  2= FX
  3 = WATS Line
  4 = Tie Line/Announcement Trunk
  5 = CCSA  6 = Toll Terminal
  7 = CAS Line  8= Paging
  9 = Code Call Trunk 10 = Dictation Trunk
11 = General Paging Trunk
12 = Radio Paging Trunk 13 - 31 = Not used
7L/TLine/Trunk Identification
0 = Not used (Line) 1 = Trunk11111Always assign data “1.”
8RLPTrunk Release Pattern
0 = Calling Party Release...

Page 572

CHAPTER 4 NDA-24298
Page 538
Issue 1
ARTDN : Assignment of Route Class Data for NDM
15 LSGLine Signal
0=Loop
1 = Ground Start C.O. Line
2=CDH
3 = Caller ID (Loop)
4=Loop
5 = E&M Tie Line
6=DX
7=24V4
8 = Loop DID 9 - 11 = Not used
12 = Speech Line (for CCIS No. 7 or Bch of ISDN)
13 = Signal Line (for CCIS No. 7 or Dch of ISDN)
14 = Not used 15 = Not used
16 SMDR2 Detailed Billing InformationSee Figure 4-16 and 
Table 4-22.
17 H/MHotel Service in CCIS No. 7
0 = Out of Service 1 = In Service
18MC...

Page 573

NDA-24298 CHAPTER 4
Page 539
Issue 1
ARTDN : Assignment of Route Class Data for NDM
Figure 4-16    SMDR2 (ARTDN)
Table 4-22 SMDR2 (ARTDN)
CONTENTS/INPUT 0123456789101112131415
b00-Detailed billing is not required for incoming calls.××××
1-Detailed billing is required for incoming calls.××××
b10-Detailed billing is required for toll and local 
outgoing calls.
×× ××
1-Detailed billing is required only for toll outgoing 
calls.×× ××
b2, 30-
1-Metering pulses are used.××××
2-
3-
b0b1b2b3 
0/1: -/Incoming...

Page 574

CHAPTER 4 NDA-24298
Page 540
Issue 1
ARTDN : Assignment of Route Class Data for NDM
LGRT
 1-899
FUNCTIONREMARKS
24 OC 0= -  
1 = Originating Category Information is used For MFC signaling
(Brazil and Mexico)
25 R/LAttendant-Identification of Incoming Trunk Display.
0 = TN, RT, TK display
1 = C.O. Line Number display
26 RVSDTrunk Reversal Identification 
This data is necessary when a specific Trunk route provides 
battery reversal for answer supervision.
0 = Battery Reversal System
1=Third Wire System
27...

Page 575

NDA-24298 CHAPTER 4
Page 541
Issue 1
ARTDN : Assignment of Route Class Data for NDM
3 2 ICRLRelease timing for incoming trunk connections.
  0 = 288 msec.Note  1 = 224 msec.
  2 = 288 msec.   3 = 352 msec. 
  4 = 416 msec.   5 = 480 msec. 
  6 = 544 msec.   7 = 608 msec. 
  8 = 672 msec.   9 = 736 msec. 
10 = 800 msec. 11 = 864 msec. 
12 = 928 msec. 13 = 992 msec. 
14 = 1056 msec. 15 = 1120 msec. Normally assign 
data “0”. 
For ISDN, see Table 
4-23 (Example of 
Route Class Set-
tings).
Note:160 msec....

Page 576

CHAPTER 4 NDA-24298
Page 542
Issue 1
ARTDN : Assignment of Route Class Data for NDM
39 BCC.O Line Idle Balance Condition.
0 = Not balanced 1 = BalancedFor Australia only
40 TCMTravel Class Mark
0 = Out of Service 1 = In Service
41 TDMQTandem Off Hook OG Queuing
0 = Out of Service 1 = In Service
42 TRSCTrunk Restriction class
0 = Out of Service 1-15= In ServiceSee AEFR command.
43 BT Inter-office Busy Service
0 = Out of Service 1 = In ServiceFor CCIS voice route, 
assign data “1.
44 PRVLine Trunk Privacy...

Page 577

NDA-24298 CHAPTER 4
Page 543
Issue 1
ARTDN : Assignment of Route Class Data for NDM
56 SMDR3Detailed billing for outgoing in tandem connection. 
0 = Required 1 = Not requiredAssign this for the 
incoming route (ICRT), 
if necessary.
5 7 HDTHeterogeneous Data Trunk
0 = Not Heterogeneous Data Trunk
1 = Heterogeneous Data Trunk
58 CDConsecutive Dialing
0 = Out of Service 1 = In Service
59 CCHCommon Channel Handler 
0 = CCH is not mounted (normal setting)
1 = CCH is mounted (ISDN or CCIS line ) 0000Always...

Page 578

CHAPTER 4 NDA-24298
Page 544
Issue 1
ARTDN : Assignment of Route Class Data for NDM
68 SCFSplit Call Forwarding 
The call is forwarded to the desired destination assigned at
0 = Split C. F. - All Calls (SSC, SID = 8), Split C. F. - 
Busy Line (SSC, SID = 10), Split C. F. - Don’t 
Answer (SSC, SID = 12)
1 = C. F. - All Calls (SSCA, SIDA = 86), C. F. - Busy 
Line (SSCA, SID = 87), C. F. - Don’t Answer (SS
CA, SIDA = 88)This data is valid when 
ASYDN, SYS,INDEX 
79, b2 = 1. 
69 SMDR4Detailed billing for...

Page 579

NDA-24298 CHAPTER 4
Page 545
Issue 1
ARTDN : Assignment of Route Class Data for NDM
7 3 KPSTDuration of KP sending  
  0 = 48 msec.   1 = 56 msec. 
  2 = 64 msec.   3 = 72 msec. 
  4 = 80 msec.   5 = 88 msec. 
  6 = 96 msec.   7 = 104 msec. 
  8 = 112 msec.   9 = 120 msec.
10 = 128 msec.  11 = 136 msec. 
12 = 144 msec. 13 = 152 msec. 
14 = 160 msec. 15 = 168 msec.
(In case of MFC) 
  0 = 12.0 sec.   1 = 5.5 sec. 
  2 = 7.0 sec.    3 = 8.5 sec. 
  4 = 10.0 sec.   5 = 11.5 sec. 
  6 = 13.0 sec.   7 = 14.5...

Page 580

CHAPTER 4 NDA-24298
Page 546
Issue 1
ARTDN : Assignment of Route Class Data for NDM
7 9 PPTMSender Prepares 
  0 = Standard   1 = 600 msec. 
  2 = 800 msec.   3 = 1000 msec. 
  4 = 1200 msec.   5 = 1400 msec.
  6 = 1600 msec.   7 = 1800 msec.
  8 = 2000 msec.   9 = 2200 msec.
10 = 2400 msec. 11 = 2600 msec. 
12 = 2800 msec. 13 = 3000 msec. 
14 = 3200 msec. 15 = 3400 msec.
(In case of MFC) 
  0 = 24.0 sec.   1 = 5.5 sec. 
  2 = 7.0 sec.   3 = 8.5 sec. 
  4 = 10.0 sec.   5 = 11.5 sec. 
  6 = 13.0 sec.   7...