    							Ensure the best quality output 141
    Use the Optimize print quality wizard
    Introduction
    The off-line screen of the printer operator panel contains the Optimize print 
    quality wizard that helps you to correct the problems with the output quality. 
    The wizard performs the following actions:
    ■Calibration
    ■Recover a nozzle failure
    ■Align the printheads for the selected media type.
    Define the settings for automatic calibration, nozzle failure detection, and 
    printhead alignment in the Océ Settings Editor. See the on-line help within the 
    Océ Settings Editor application. You can start the calibration, nozzle failure 
    detection and printhead alignment from the printer operator panel.
    During the Optimize print quality wizard, the system performs an alignment. 
    The alignment requires the use of media. Make sure at least one roll of media 
    is loaded before you enter the Optimize print quality wizard.
    When to do
    Before you start the Optimize print quality wizard, first check the following:
    ■Did you use the correct media type?
    ■Did you use the correct print mode?
    Only start the wizard when you are sure that you used the correct media type 
    and the correct print mode and if the output quality is still not satisfactory.
    How to use the Optimize print quality wizard
    1
    Press the on-line / off-line key to set the printer off-line.
    2Press the upper softkeys to scroll to the Optimize print quality card.
    Downloaded From ManualsPrinter.com Manuals 
    						
    							142 Océ TCS400 User manual
    3Press the lower softkey for Optimize print quality to enter the wizard.
    An introduction screen displays the message Use this wizard to optimize the 
    print quality. A roll must be available on the printer for use during calibration.
    4Press the key for Next.
    The screen displays the message Select roll to use. 
    You can only calibrate on six defined media types (see ‘Overnight printing’ on 
    page179). When calibration is not possible with the loaded media, the system 
    asks you to load the correct media. When calibration is possible with one of 
    the rolls, the system automatically uses the correct roll of media. When 
    calibration is possible with both rolls, continue with step 5.
    5Press the lower softkeys to select a media roll for the calibration.
    6Press the key for Next.
    The screen displays the message Preparing calibration... The system prepares 
    for the quality check.
    Downloaded From ManualsPrinter.com Manuals 
    						
    							Ensure the best quality output 143
    The screen displays feedback about the calibration process. The system does a 
    nozzle failure recovery.
    You can stop the calibration process at any time. Press the key for Cancel to 
    stop the calibration process.
    When there are no defective printheads, you can perform a printhead 
    alignment. The screen displays the message All printheads OK. Perform 
    alignment?
    7Press the key for Yes. The system performs a printhead alignment. The screen 
    displays the message Aligning printheads...
    When you select No, the system returns to the off-line menu.
    When there are printheads with defective nozzles, you cannot do a printhead 
    alignment. The screen displays the message defective printheads with the 
    color and number of the defective printheads.
    8Press the key for Replace to enter the Replace printhead wizard (see ‘Replace 
    a defective printhead’ on page186).
    Press the key for Ignore to return to the off-line screen.
    Note:When the fallback mode is disabled in the Océ Settings Editor or when 
    more than one printhead of one color is defective, you must replace the 
    defective printheads immediately.
    Downloaded From ManualsPrinter.com Manuals 
    						
    							144 Océ TCS400 User manual
    Optimize the output quality from the scanner
    Introduction
    The Océ TCS400 scanner has the following methods to make sure you have a 
    consistent output quality:
    ■Automatic scanner adjustment
    The scanner automatically makes the adjustments to make sure the quality 
    is consistent.
    ■Settings on the scanner operator panel
    ■Scanner calibration.
    This section describes different methods which you can use to optimize the 
    output quality from the scanner for your copy jobs and your scan-to-file jobs.
    Downloaded From ManualsPrinter.com Manuals 
    						
    							Ensure the best quality output 145
    Problem analysis and solutions
    [29 ] Proble m anal ys is  and  sol uti ons
    [29] Problem analysis and solutions
    Problem Solutions
    The image on the output is some 
    what wrong aligned.Enable the Deskew function on the 
    System screen of the scanner opera-
    tor panel.
    Use Deskew for originals that do not 
    contain lines or text.
    Deskew is especially useful for small 
    originals.
    Pollution of the background of the 
    imageUse the arrow keys to enable the Au-
    tom. background compensation 
    function on the Image card of the 
    scanner operator panel.
    When the glass plate and the white 
    platen are dirty, the background of 
    the image can also become polluted. 
    When the glass plate and the white 
    platen are dirty, clean the glass plate 
    and the white platen. (see ‘Clean the 
    scan area’ on page197)
    The image is too dark or too light. 
    There is not enough contrast between 
    dark and light areas in the image.Use the Dark areas and the Light ar-
    eas settings on the Image card of the 
    scanner operator panel. Use the left 
    and right arrow keys to increase or 
    decrease the exposure.
    General problems with the quality of 
    the output.Use the Scanner calibration wizard 
    on the System screen of the scanner 
    operator panel to calibrate the scan-
    ner.
    Downloaded From ManualsPrinter.com Manuals 
    						
    							146 Océ TCS400 User manual
    Calibrate the scanner
    Introduction
    To maintain a consistent quality of the output, the Océ TCS400 scanner 
    operator panel has a calibration wizard. 
    When to do
    Use the scanner calibration wizard to get consistent output of high quality.
    Between 2 scanner calibrations, the automatic scanner adjustment stabilizes 
    the output quality. The automatic scanner adjustment keeps the scanner 
    independent of changes in the environment.
    Use the scanner calibration wizard to start a scanner calibration when the scan 
    quality decreases.
    Use the scanner calibration wizard when the following error message appears 
    on the screen.
    ■Unable to align the cameras. Please calibrate the scanner.
    Before you begin
    ■Turn on the scanner at least one hour before you do the scanner calibration
    The scanner needs one hour to warm-up for optimal calibration.
    ■Clean the glass plate of the scanner
    (see ‘Clean the scan area’ on page197)
    ■Clean the white platen of the scanner
    (see ‘Clean the scan area’ on page197)
    ■Clean the calibration sheet
    ■The scanner operator panel must display Ready.
    ■Make sure the IT8 file matches the scanner calibration sheet.
    (see ‘Update the IT8 file for scanner calibration’ on page149)
    Required tool
    The scanner calibration sheet inside the front compartment. 
    Downloaded From ManualsPrinter.com Manuals 
    						
    							Ensure the best quality output 147
    How to calibrate the scanner
    1
    Press the upper key for System on the home screen.
    2Press the lower key for Scanner calibration to enter the wizard.[39 ] Entry  to the  sc anner c ali bratio n wiz ard on t he Sy st em s creen.
    [39] Entry to the scanner calibration wizard on the System screen.
    The screen displays Use this wizard to calibrate the scanner and the time and 
    the date of the last successful calibration.
    [40 ] Th e firs t st ep of th e sc anne r c al ibrati on wi zard
    [40] The first step of the scanner calibration wizard
    3Press the upper key for Next.
    The screen prompts you to clean the glass plate and white platen.
    [41 ] Th e se con d ste p of the  sc anne r c al ibrati on wi zard
    [41] The second step of the scanner calibration wizard
    Downloaded From ManualsPrinter.com Manuals 
    						
    							148 Océ TCS400 User manual
    4After you cleaned the glass plate and white platen, press the key for Next. 
    5Place the calibration sheet face down, center aligned.[42 ] The thi rd  ste p of the  sc anner c ali brati on wiz ard
    [42] The third step of the scanner calibration wizard
    6Press the key for Next.
    The scanner starts the calibration. The calibration takes 10 minutes. If you 
    press the key for Cancel, the calibration process aborts. Then, the screen 
    prompts you to remove the calibration sheet.
    [43 ] The fourth  step  of the s c anner c ali bratio n wiz ard
    [43] The fourth step of the scanner calibration wizard
    7If the calibration is completed, remove the calibration sheet. [44 ] The fi fth s tep of t he s cann er  cal ibrati on wi zard
    [44] The fifth step of the scanner calibration wizard
    8Press the key for Done.
    The scanner returns to the System screen.
    Downloaded From ManualsPrinter.com Manuals 
    						
    							Ensure the best quality output 149
    Update the IT8 file for scanner calibration
    Introduction
    This section explains how to update the IT8 file which is paired to the scanner 
    calibration sheet. 
    Note:You must log on as system administrator in the Océ Settings Editor to 
    update the IT8 file.
    When to do
    The IT8 file must match the scanner calibration sheet, which is normally found 
    inside the front compartment of the scanner. You can find the IT8 file on the 
    disk supplied with the scanner calibration sheet.
    If you receive a new scanner calibration sheet, replace the IT8 file on the 
    controller with the IT8 file received with the scanner calibration sheet.
    How to update the IT8 file
    1
    Log on to the system administrator mode in the Océ Settings Editor.
    2From the Calibration menu, select Scanner.
    The Scanner calibration window appears.
    3Click the Browse button and browse to the location of the IT8 file.
    4Select the IT8 file and click the Upload button.
    The system uploads the IT8 file. When the IT8 file is correctly uploaded, the 
    system gives a confirmation.