Have a look at the manual Panasonic Digital Copier DP-2000/2500/3000 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
101 Troubleshooting Appendix Printing/Scanning Area Top 0.1/2.5 0.1/2.5 0.1/2.5 Bottom (Unit: inches/mm) 0.1/2.5
Appendix 102 Parallel Interface Connector The printer has a parallel interface for connecting to PC. Shape of Connector Signal lines and pin arrangement *Signal used for bidirectional communication No. I/OSignal nameNo. I/OSignal name 1 I /STB 19 GND 2 I/O DATA0 20 GND 3 I/O DATA1 21 GND 4 I/O DATA2 22 GND 5 I/O DATA3 23 GND 6 I/O DATA4 24 GND 7 I/O DATA5 25 GND 8 I/O DATA6 26 GND 9 I/O DATA7 27 GND 10 O /ACK 28 GND 11 O BUSY 29 GND 12 O PE 30 GND 13 I SELECT 31 I /INIT 14 O /AUTOFD* 32 O /FAULT 15 Not used 33 Not used 16 GND 34 Not used 17 GND 35 Not used 18 O VCC 36 I /SELIN* Signal functions Signal name Function /STB Signal for sending data to printer. Steady-state value is High. Printer reads data until this signal becomes from Low to High. DATA0 to Input signal for receiving 8-bit data. Data7 Logic 1 is High. DATA0 is LSB and DATA 7 is MSB. /ACK Signal indicating that printer has read data into device completely. This signal is output in response to /STB. BUSY Signal indicating that printer is unable to receive data. Printer is able to receive data when this signal is Low. PE Signal indicating Paper Out of printer. This signal is Low when paper is loaded and is High when paper is out. SELECT Signal indicating that printer is under online status. Printer is capable of receiving data when this signal is High. /AUTFD Signal used for bidirectional communication GND Ground VCC Signal indicating that the power of printer is on. This signal allows verifying ON/OFF status of power of printer and connection status of printer cable. /INT Signal for initializing printer. Steady- state value is High. Printer is initialized by Low. /FAULT Signal indicating that printer is faulty. /SELIN Signal used for bidirectional communication
Appendix 103 Troubleshooting Font Code Font Code 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44PCL Font CG-Times CG-Times Italic CG -Times Bold CG-Times Bold Italic Univers Univers Italic Univers Bold Univers Bold Italic Univers Condensed Univers Condensed Italic Univers Condensed Bold Univers Condensed Bold Italic Antique Olive Antique Olive Italic Antique Olive Bold CG Omega CG Omega Italic CG Omega Bold CG Omega Bold Italic Garamond Garamond Italic Garamond Bold Garamond Bold Italic Courier Medium Courier Italic Courier Bold Courier Bold Italic Letter Gothic Regular Letter Gothic Bold Letter Gothic Italic Albertus Medium Albertus Extrabold Clarendon Condensed Coronet Marigold Arial Arial Italic Arial Bold Arial Bold Italic Times New Roman Times New Roman Italic Times New Roman Bold Times New Roman Bold Italic Symbol WingdingsCompatible font Dutch 810 SWC Dutch 810 Italic SWC Dutch 810 Bold SWC Dutch 810 Bold Italic SWC Swiss 742 SWC Swiss 742 Italic SWC Swiss 742 Bold SWC Swiss 742 Bold Italic SWC Swiss 742 Condensed SWC Swiss 742 Condensed Italic SWC Swiss 742 Condensed Bold SWC Swiss 742 Condensed Bold Italic SWC Incised 901 SWC Incised 901 Italic SWC Incised 901 Bold SWC Zapf Humanist 601 SWC Zapf Humanist 601 Italic SWC Zapf Humanist 601 Bold SWC Zapf Humanist 601 Bold Italic SWC Aldine 430 Original Garamond SWC Aldine 430 Original Garamond Italic SWC Aldine 430 Original Garamond Bold SWC Aldine 430 Original Garamond Bold Italic SWC Fixed Pitch 810 Courier Roman SWC Fixed Pitch 810 Courier Italic SWC Fixed Pitch 810 Courier Bold SWC Fixed Pitch 810 Courier Bold Italic SWC Fixed Pitch 850 Letter Gothic 12 pitch//text SWC Fixed Pitch 850 Letter Gothic Bold 12 pitch//text SWC Fixed Pitch 850 Letter Gothic Italic 12 pitch//text SWC Flareserif 821 SWC Flareserif 821 Extra Bold SWC Clarendon 701 Condensed SWC Ribbon 131 SWC Audrey Two SWC Swiss 721 SWM Swiss 721 Oblique SWM Swiss 721 Bold SWM Swiss 721 Bold Oblique SWM Dutch 801 SWM Dutch 801 Italic SWM Dutch 801 Bold SWM Dutch 801 Bold Italic SWM Symbol SWA Wingbats SWM
Appendix 104 Symbol Table No. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35Symbol Set Legal (HP Legal) ISO 4 (United Kingdom) ISO 6 (ANSI, ASCII) ISO 11 (Swedish/French) ISO 15 (Italian) ISO 17 (Spanish) ISO 21 (German) ISO 60 (Norwegian, v.1) ISO 69 (French) ISO 8859/2 Latin 2 ISO 8859/2 Latin 5 PC-8 (IBM-8, Code Page 437) PC-8 DN (Denmark/Norway) PC-850 (IBM-850) PC-8 TK (Code Page 437T) PC-852 Latin 2 Roman 8 Desk Top ECMA 94 (Latin 1) Macintosh Math 8 (HP Math 8) Microsoft Publishing Pi Font (HP Pi Font) PS Math PS Text Ventura International Ventura Math Ventura US Windows Windows 3.1 Windows 3.1 Latin 2 Windows 3.1 Latin 5 Symbol, Windows 3.1 Wingdings, Windows 3.1 Baltic (PC-1004) Baltic (PC-775 Baltic)
WARRANTY “PANASONIC DOCUMENT IMAGING COMPANY MAKES NO WARRANTIES, GUARANTEES OR REPRESENTATIONS, EXPRESSED OR IMPLIED, TO CUSTOMER WITH RESPECT TO THIS PANASONIC COPIER, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. PANASONIC DOCUMENT IMAGING COMPANY ASSUMES NO RISK AND SHALL NOT BE SUBJECT TO LIABILITY FOR ANY DAMAGE, INCLUDING, BUT NOT LIMITED TO DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSS OF PROFITS SUSTAINED BY THE CUSTOMER IN CONNECTION WITH THE USE OR APPLICATION OF THIS PANASONIC COPIER. SEE YOUR DEALER FOR DETAILS OF DEALERS WARRANTY.” Panasonic Document Imaging Company A Division of Matsushita Electric Corporation of America Two Panasonic way Secaucus, New Jersey 07094 T1000-1031 DZSD001099-1 March 2001 Printed in Japan U.S.A. only For Service Call: Panasonic Canada Inc. 5770 Ambler Drive, Mississauga, Ontario L4W 2T3