Home > Samsung > Processor > Samsung Exynos 5 User Manual

Samsung Exynos 5 User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Samsung Exynos 5 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1705 Samsung manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 881
    							Samsung Confidential  
    Exynos 5250_UM 4 Pad Control 
     4-217  
    4.4.1.313 EXT_INT15CON 
     Base Address: 0x1340_0000 
     Address = Base Address + 0x0704, Reset Value = 0x0000_0000 
    Name Bit Type Description Reset Value 
    RSVD [31:8] –=Reserved=0x000000=
    RSVD=[7]=–=Reserved=0x0=
    EXT_INT15=
    _CON[1]=[6:4]=RW=
    Setting the signaling method=of EXT_INT15[1]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[3]=–=Reserved=0x0=
    EXT_INT15=
    _CON[0]=[2:0]=RW=
    Setting the signaling method=of EXT_INT15[0]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    =
    = 
    						
    							Samsung Confidential  
    Exynos 5250_UM 4 Pad Control 
     4-218  
    4.4.1.314 EXT_INT16CON 
     Base Address: 0x1340_0000 
     Address = Base Address + 0x0708, Reset Value = 0x0000_0000 
    Name Bit Type Description Reset Value 
    RSVD [31:16] –=Reserved=0x0000=
    RSVD=[15]=–=Reserved=0x0=
    EXT_INT1S=
    _CON[3]=[14:12]=RW=
    Setting the signaling method=of EXT_INT16[3]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[11]=–=Reserved=0x0=
    EXT_INT1S=
    _CON[2]=[10:8]=RW=
    Setting the signaling method=of EXT_INT16[2]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[7]=–=Reserved=0x0=
    EXT_INT1S=
    _CON[1]=[6:4]=RW=
    Setting the signaling method=of EXT_INT16[1]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[3]=–=Reserved=0x0=
    EXT_INT1S=
    _CON[0]=[2:0]=RW=
    Setting the signaling method=of EXT_INT16[0]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    =
    = 
    						
    							Samsung Confidential  
    Exynos 5250_UM 4 Pad Control 
     4-219  
    4.4.1.315 EXT_INT17CON 
     Base Address: 0x1340_0000 
     Address = Base Address + 0x070C, Reset Value = 0x0000_0000 
    Name Bit Type Description Reset Value 
    RSVD [31:16] –=Reserved=0x0000=
    RSVD=[15]=–=Reserved=0x0=
    EXT_INT17=
    _CON[3]=[14:12]=RW=
    Setting the signaling method=of EXT_INT17[3]=
    0x0 ==Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[11]=–=Reserved=0x0=
    EXT_INT17=
    _CON[2]=[10:8]=RW=
    Setting the signaling method=of EXT_INT17[2]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[7]=–=Reserved=0x0=
    EXT_INT17=
    _CON[1]=[6:4]=RW=
    Setting the signaling method=of EXT_INT17[1]=
    0x0 = Sets=Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[3]=–=Reserved=0x0=
    EXT_INT17=
    _CON[0]=[2:0]=RW=
    Setting the signaling method=of EXT_INT17[0]=
    0x0 = Sets Low=level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    =
    = 
    						
    							Samsung Confidential  
    Exynos 5250_UM 4 Pad Control 
     4-220  
    4.4.1.316 EXT_INT18CON 
     Base Address: 0x1340_0000 
     Address = Base Address + 0x0710, Reset Value = 0x0000_0000 
    Name Bit Type Description Reset Value 
    RSVD [31] –=Reserved=0x0=
    EXT_INT18=
    _CON[7]=[30:28]=RW=
    Setting the signaling method=of EXT_INT18[7]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[27]=–=Reserved=0x0=
    EXT_INT18=
    _CON[6]=[26:24]=RW=
    Setting the signaling method=of EXT_INT18[6]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[23]=–=Reserved=0x0=
    EXT_INT18=
    _CON[5]=[22:20]=RW=
    Setting the signaling method of EXT_INT18[5]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[19]=–=Reserved=0x0=
    EXT_INT18=
    _CON[4]=[18:16]=RW=
    Setting the signaling method of EXT_INT18[4]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[15]=–=Reserved=0x0=
    EXT_INT18=
    _CON[3]=[14:12]=RW=
    Setting the signaling method of EXT_INT18[3]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4== Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[11]=–=Reserved=0x0=
    EXT_INT18=[10:8]=RW=Setting the signaling method=of EXT_INT18[2]=0x0= 
    						
    							Samsung Confidential  
    Exynos 5250_UM 4 Pad Control 
     4-221  
    Name Bit Type Description Reset Value 
    _CON[2] 0x0 = Sets Low level 
    0x1 = Sets High level 
    0x2 = Triggers Falling edge  
    0x3 = Triggers Rising edge  
    0x4 = Triggers Both edge  
    0x5 to 0x7 = Reserved 
    RSVD [7] – Reserved 0x0 
    EXT_INT18 
    _CON[1] [6:4] RW 
    Setting the signaling method of EXT_INT18[1] 
    0x0 = Sets Low level 
    0x1 = Sets High level 
    0x2 = Triggers Falling edge  
    0x3 = Triggers Rising edge  
    0x4 = Triggers Both edge  
    0x5 to 0x7 = Reserved 
    0x0 
    RSVD [3] – Reserved 0x0 
    EXT_INT18 
    _CON[0] [2:0] RW 
    Setting the signaling method of EXT_INT18[0] 
    0x0 = Sets Low level 
    0x1 = Sets High level 
    0x2 = Triggers Falling edge  
    0x3 = Triggers Rising edge  
    0x4 = Triggers Both edge  
    0x5 to 0x7 = Reserved 
    0x0 
     
      
    						
    							Samsung Confidential  
    Exynos 5250_UM 4 Pad Control 
     4-222  
    4.4.1.317 EXT_INT19CON 
     Base Address: 0x1340_0000 
     Address = Base Address + 0x0714, Reset Value = 0x0000_0000 
    Name Bit Type Description Reset Value 
    RSVD [31] –=Reserved=0x0=
    EXT_INT19=
    _CON[7]=[30:28]=RW=
    Setting the signaling method=of EXT_INT19[7]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[27]=–=Reserved=0x0=
    EXT_INT19=
    _CON[6]=[26:24]=RW=
    Setting the signaling method=of EXT_INT19[6]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[23]=–=Reserved=0x0=
    EXT_INT19=
    _CON[5]=[22:20]=RW=
    Setting the signaling method=of EXT_INT19[5]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[19]=–=Reserved=0x0=
    EXT_INT19=
    _CON[4]=[18:16]=RW=
    Setting the signaling method=of EXT_INT19[4]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[15]=–=Reserved=0x0=
    EXT_INT19=
    _CON[3]=[14:12]=RW=
    Setting the signaling method=of EXT_INT19[3]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[11]=–=Reserved=0x0=
    EXT_INT19=[10:8]=RW==Setting the signaling method=of EXT_INT19[2]=0x0= 
    						
    							Samsung Confidential  
    Exynos 5250_UM 4 Pad Control 
     4-223  
    Name Bit Type Description Reset Value 
    _CON[2] 0x0 = Sets Low level 
    0x1 = Sets High level 
    0x2 = Triggers Falling edge  
    0x3 = Triggers Rising edge  
    0x4 = Triggers Both edge  
    0x5 to 0x7 = Reserved 
    RSVD [7] – Reserved 0x0 
    EXT_INT19 
    _CON[1] [6:4] RW 
    Setting the signaling method of EXT_INT19[1] 
    0x0 = Sets Low level 
    0x1 = Sets High level 
    0x2 = Triggers Falling edge  
    0x3 = Triggers Rising edge  
    0x4 = Triggers Both edge  
    0x5 to 0x7 = Reserved 
    0x0 
    RSVD [3] – Reserved 0x0 
    EXT_INT19 
    _CON[0] [2:0] RW 
    Setting the signaling method of EXT_INT19[0] 
    0x0 = Sets Low level 
    0x1 = Sets High level 
    0x2 = Triggers Falling edge  
    0x3 = Triggers Rising edge  
    0x4 = Triggers Both edge  
    0x5 to 0x7 = Reserved 
    0x0 
     
      
    						
    							Samsung Confidential  
    Exynos 5250_UM 4 Pad Control 
     4-224  
    4.4.1.318 EXT_INT20CON 
     Base Address: 0x1340_0000 
     Address = Base Address + 0x0718, Reset Value = 0x0000_0000 
    Name Bit Type Description Reset Value 
    RSVD [31:8] –=Reserved=0x000000=
    RSVD=[7]=–=Reserved=0x0=
    EXT_INT20=
    _CON[1]=[6:4]=RW=
    Setting the signaling method=of EXT_INT20[1]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[3]=–=Reserved=0x0=
    EXT_INT20=
    _CON[0]=[2:0]=RW=
    Setting the signaling method=of EXT_INT20[0]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    =
    = 
    						
    							Samsung Confidential  
    Exynos 5250_UM 4 Pad Control 
     4-225  
    4.4.1.319 EXT_INT21CON 
     Base Address: 0x1340_0000 
     Address = Base Address + 0x071C, Reset Value = 0x0000_0000 
    Name Bit Type Description Reset Value 
    RSVD [31:16] –=Reserved=0x0000=
    RSVD=[15]=–=Reserved=0x0=
    EXT_INT21=
    _CON[3]=[14:12]=RW=
    Setting the signaling method=of EXT_INT21[3]=
    0x0 = Sets=Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[11]=–=Reserved=0x0=
    EXT_INT21=
    _CON[2]=[10:8]=RW=
    Setting the signaling method=of EXT_INT21[2]=
    0x0 = Sets Low=level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[7]=–=Reserved=0x0=
    EXT_INT21=
    _CON[1]=[6:4]=RW=
    Setting the signaling method=of EXT_INT21[1]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[3]=–=Reserved=0x0=
    EXT_INT21=
    _CON[0]=[2:0]=RW=
    Setting the signaling method=of EXT_INT21[0]=
    0x0 = Sets Low level=
    0x1 ==Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    =
    = 
    						
    							Samsung Confidential  
    Exynos 5250_UM 4 Pad Control 
     4-226  
    4.4.1.320 EXT_INT22CON 
     Base Address: 0x1340_0000 
     Address = Base Address + 0x0720, Reset Value = 0x0000_0000 
    Name Bit Type Description Reset Value 
    RSVD [31] –=Reserved=0x0=
    EXT_INT22=
    _CON[7]=[30:28]=RW=
    Setting the signaling method=of EXT_INT22[7]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[27]=–=Reserved=0x0=
    EXT_INT22=
    _CON[6]=[26:24]=RW=
    Setting the signaling method=of EXT_INT22[6]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[23]=–=Reserved=0x0=
    EXT_INT22=
    _CON[5]=[22:20]=RW=
    Setting the signaling method=of EXT_INT22[5]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[19]=–=Reserved=0x0=
    EXT_INT22=
    _CON[4]=[18:16]=RW=
    Setting the signaling method=of EXT_INT22[4]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[15]=–=Reserved=0x0=
    EXT_INT22=
    _CON[3]=[14:12]=RW=
    Setting the signaling method=of EXT_INT22[3]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4== Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[11]=–=Reserved=0x0=
    EXT_INT22=[10:8]=RW=Setting the signaling method=of EXT_INT22[2]=0x0= 
    						
    All Samsung manuals Comments (0)