    							Probes
    Vivid7/Vivid7 PRO Users Manual357
    FC092326-03
    Linear Array probes
    7S2D mode
    M-Mode
    Color Flow
    CW Doppler
    PW Doppler• Cardiology
    • Coronary
    • PediatricFrequency:
    Foot print:3.0 - 8.0 MHz
    15 x 21 mm
    10S2D mode
    M-Mode
    Color Flow
    CW Doppler
    PW Doppler• Cardiology
    • Coronary
    • PediatricFrequency:
    Foot print:4.0 - 12.0 MHz
    10 x 14 mm Probe Mode Intended use Technical data
    Probe Mode Intended use Technical data
    7L 2D mode
    M-Mode
    Color Flow
    CW Doppler
    PW Doppler• Peripheral 
    vascular
    • Small partsFrequency:
    Foot print:3.2 - 7.5 MHz
    17 x 58 mm
    10L 2D mode
    M-Mode
    Color Flow
    CW Doppler
    PW Doppler• Small parts
    • peripheral 
    vascularFrequency:
    Foot print:4.0 - 11.0 MHz
    17 x 49 mm 
    						
    							Probes
    358Vivid7/Vivid7 PRO Users Manual
    FC092326-03
    12L 2D mode
    M-Mode
    Color Flow
    CW Doppler
    PW Doppler• Small parts
    • peripheral 
    vascularFrequency:
    Foot print:5.0 - 11.5 MHz
    17 x 49 mm
    M12L
    a)2D mode
    M-Mode
    Color Flow
    CW Doppler
    PW Doppler• Carotid
    • SuperficialFrequency:
    Foot print:5.0 - 13.0 MHz
    10 x 45 mm
    i8L2D mode
    M-Mode
    Color Flow
    CW Doppler
    PW Doppler• Cardiac 
    intraoperativ
    eFrequency:
    Foot print:5.0 - 8.0 MHz
    16 x 44 mm
    i13L2D mode
    M-Mode
    Color Flow
    CW Doppler
    PW Doppler• Cardiac 
    intraoperativ
    eFrequency:
    Foot print:8.0 - 13.0 MHz
    10 x 28 mm
    a) Vivid 7 only Probe Mode Intended use Technical data 
    						
    							Probes
    Vivid7/Vivid7 PRO Users Manual359
    FC092326-03
    Cur ved Array (Convex) probes
    Probe Mode Intended use Technical data
    3.5C2D mode
    M-Mode
    Color Flow
    CW Doppler
    PW Doppler• Abdomen
    • Fetal Heart
    • Obstetrics
    • Pelvic
    • RenalFrequency:
    Foot print:
    FOV:2.4 - 5.0 MHz
    18 x 64 mm
    58 degrees
    5C2D mode
    M-Mode
    Color Flow
    CW Doppler
    PW Doppler• Abdomen
    • Fetal Heart
    • Obstetrics
    • Pelvic
    • RenalFrequency:
    Foot print:
    FOV:3.6 - 8.0 MHz
    17 x 58 mm
    73 degrees
    M7C2D mode
    M-Mode
    Color Flow
    CW Doppler
    PW Doppler• Abdomen Frequency:
    Foot print:
    FOV:3.0 - 8.0 MHz
    18 x 55 mm
    75 degrees
    8C2D mode
    M-Mode
    Color Flow
    CW Doppler
    PW Doppler• Abdomen Frequency:
    Foot print:
    FOV:4.0 - 10.0 MHz
    23 x 10 mm
    133 degrees
    E8C2D mode
    Color Flow
    CW Doppler
    PW Doppler• Fetal Heart
    • Obstetrics
    • PelvicFrequency:
    Foot print:
    FOV:4.0 - 10.0 MHz
    23 x 10 mm
    133 degrees 
    						
    							Probes
    360Vivid7/Vivid7 PRO Users Manual
    FC092326-03
    Doppler probe
    Multiplane Transesophageal Phased Array 
    probe
    Probe Mode Intended use Technical data
    2D (P2D)CW Doppler •  Cardiology Frequency: 2.0 MHz
    6D (P6D)CW Doppler •  Carotid Frequency: 6.0 MHz
    Probe Mode Intended use Technical data
    6T2D mode
    M-Mode
    Color Flow
    CW Doppler
    PW Doppler• Transesopha
    geal 
    CardiologyFrequency: 2.9 - 6.7 MHz
    7T2D mode
    M-Mode
    Color Flow
    CW Doppler
    PW Doppler• Transesopha
    geal 
    CardiologyFrequency: 3.0 - 8.0 MHz 
    						
    							Probes
    Vivid7/Vivid7 PRO Users Manual361
    FC092326-03
    9T2D mode
    M-Mode
    Color Flow
    CW Doppler
    PW Doppler• Transesopha
    geal pediatric 
    CardiologyFrequency: 3.3 - 10.0 MHz
    5T PAMPTE2D mode
    M-Mode
    Color Flow
    CW Doppler
    PW Doppler• Transesopha
    geal 
    CardiologyFrequency: 2.9 - 6.7 MHz
    8T2D mode
    M-Mode
    Color Flow
    CW Doppler
    PW Doppler• Transesopha
    geal pediatric 
    CardiologyFrequency: 3.3 - 8.0 MHz Probe Mode Intended use Technical data 
    						
    							Probes
    362Vivid7/Vivid7 PRO Users Manual
    FC092326-03
    Probe orientation
    Some probes are provided with a green light (LED) orientation 
    marking near their head (see Figure 10-1). Probes which do 
    not have a LED have an indentation (notch) for orientation on 
    the probe housing. This LED, or notch, corresponds with the V 
    mark on the scanning screen. The V mark indicates the 
    orientation of the probe to the scan.
     Figure 10-1: Orientation marking on probe and on screen
    Probe labelling
    Each probe is labelled with the following information:
    •  Name of distributor and manufacturer
    • Operating frequency
    • Model number
    •  Probe serial number
    • Year of manufacture
    1. LED
    2. Notch3. V-mark on screen: indicates the orientation of 
    the probe to the scan. 
    						
    							Probes
    Vivid7/Vivid7 PRO Users Manual363
    FC092326-03
    The probe name displayed on both the probe housing and the 
    connector can be read when the probe is connected.
     Figure 10-2: Probe labelling (examples)
    1. CE mark
    2. Probe name
    M12L
          
    MODEL2250695SERIAL 
    						
    							Probes
    364Vivid7/Vivid7 PRO Users Manual
    FC092326-03
    Probe Integration
    This section covers:
    •  Connecting the probe
    • Activating the probe
    •  Disconnecting the probe
    Connecting the probe
    Probes can be connected at any time, whether the unit is on or 
    off.
    To connect a probe:
    1. Hold the probe connector vertically with the cable pointing 
    upward.
    2. Turn the connector locking handle to the horizontal 
    position.
    3. Align the connector with the probe port and carefully push 
    into place.
    4. Rotate the locking handle to the full vertical position to lock 
    in place.
    5. Position the probe cable so that it is not resting on the floor.
    CAUTIONDo not allow the probe head to hang freely. Impact to the probe 
    head may result in irreparable damage.
    WARNINGDo NOT touch the patient and any of the connectors on the 
    ultrasound unit simultaneously, including ultrasound probe 
    connectors.
    CAUTIONTake the following precautions with the probe cables:
    •  Keep free from the wheels.
    • Do not bend.
    •  Do not cross cables between probes. 
    						
    							Probes
    Vivid7/Vivid7 PRO Users Manual365
    FC092326-03
    Connecting the PAMPTE or the 6Tv probe
    The PAMPTE and the 6Tv probes are equipped with a Vivid 
    Five connector. To connect the these probes on the Vivid 7/
    Vivid 7 PRO, an adaptor must be used (see Figure 10-3).
    To connect the PAMPTE or 6Tv probe:
    1. Turn the probe connector locking handle to the horizontal 
    position.
    2. Align the connector with the adaptor port and carefully push 
    into place.
    3. Rotate the probe connector locking handle to the full 
    vertical position to lock the probe connector and the 
    adaptor together.
    4. Ensure that the locking handle on the adaptor is in up 
    position (see Figure 10-3).
    5. Align the adaptor with the probe port and carefully push into 
    place.
    6. Move the locking handle to the down position to lock in 
    place (see Figure 10-3).
    7. Position the probe cable so that it is not resting on the floor.
    CAUTIONTransesophageal probes require a special handling. Refer to the 
    user documentation enclosed with these probes.  
    						
    							Probes
    366Vivid7/Vivid7 PRO Users Manual
    FC092326-03
     Figure 10-3: The PAMPTE probe adaptor
    Activating the probe
    When a probe is connected to the unit it is automatically 
    detected.
    To select a probe and an application:
    To change applica-
    tion without chang-
    ing the current 
    probe, press 
    APPL. 
    on the control pan-
    el.
    1. Press PROBE on the control panel. A list of the connected 
    probes will pop up.
    2. Trackball to the desired probe. 
    An application menu for the desired probe is then listed.
    3. Trackball to the desired application
    4. Press 
    SELECT to launch the application.
    1. PAMPTE or 6Tv 
    probe connector in
    2. To Vivid 7/
    Vivid 7 PRO probe 
    port
    3. Unlocked position
    4. Locked position 
    						