    							Getting started
    Vivid7/Vivid7 PRO Users Manual37
    FC092326-03
    Clear, Menu, and Image Store keys
    VCR Control and Print key
    Key Description
    Used for navigation between menus and 
    screens. 
    CLEAR brings the display back to the 
    previous state.
    Activates menu with additional options and 
    controls not available from the assignable keys.
    Stores the currently active imaging window to 
    disk. The stored information depends of the 
    configuration of the current application. Stored 
    images are shown on the clipboard.
    Menu
    Key Description
    Rec/PauseToggles the VCR to Record or Pause. For further 
    information about using VCR, Refer to page 381.
    Prints the current imaging screen content to a 
    selected (configurable) printer. For more 
    information about printing. Refer to page 381. 
    The 
    PRINT key can also be configured for 
    alternative storing of images (Refer to 
    page 432.).
    Prints the current imaging screen content to a 
    printer assigned to a second port (configurable). 
    For more information about printing, Refer to 
    page 388. The 
    ALT key can also be configured 
    for alternative storing of images (Refer to 
    page 432.). 
    						
    							Getting started
    38Vivid7/Vivid7 PRO Users Manual
    FC092326-03
    Trackball operation
    The Trackball area consists of the trackball and five 
    surrounding keys. Three of these have the very same function 
    (the select function) for ergonomic reasons. 
    Key Description
    TrackballUsed for navigation and together with the 
    surrounding keys, to move, select or activate 
    objects on the screen.
    Trackball keyControls the trackball assignments between the 
    mode-specific options. By pressing 
    TRACKBALL, 
    the trackball function will cycle through the 
    possible assignments, which are indicated in the 
    lower right corner of the screen.
    SelectActivates selections made by using the trackball. 
    The select function works in much the same way 
    as the left button on a PC mouse. The key is 
    duplicated for ergonomic reasons.
    Update MenuIn live mode, toggles between 2D imaging and 
    live time-motion imaging (Doppler/M-Mode). In 
    freeze, displays the function-specific menu 
    (same function as 
    MENU, on page 37). 
    						
    							Getting started
    Vivid7/Vivid7 PRO Users Manual39
    FC092326-03
    Assignable keys and rotar y knobs
    The functions of the assignable keys vary according to the 
    mode and/or module in which the user is working.
    Key Description
    Assignable 
    rotary knobsFour rotary knobs, whose functions vary 
    according to the scan mode and position that is 
    currently active. The assigned functions are 
    indicated above the rotary on the LCD display. 
    The mode-specific functions for these rotary 
    knobs are described in Chapter 3, ’Scanning 
    Modes’ on page 89.
    Assignable 
    ButtonsFive buttons, whose functions vary according to 
    the scan mode and position that is currently 
    active. The assigned functions are indicated 
    above the button on the LCD display. The mode-
    specific functions for these buttons are described 
    in Chapter 3, ’Scanning Modes’ on page 89.
    Gives access to additional controls from the 
    assignable buttons. 
    						
    							Getting started
    40Vivid7/Vivid7 PRO Users Manual
    FC092326-03
    The soft menu rocker
    The F1 to F4 keys
    Key Description
    Soft Menu 
    RockerA 4-way rocker used to access mode-specific 
    menus, select a menu option and adjust option-
    related values.
    •  The vertical arrows are used to select the menu 
    options.
    •  The horizontal arrows are used to adjust the 
    values. 
    The mode-specific menus are described in 
    Chapter 3, ’Scanning Modes’ on page 89.
    Key Description
    Function
    1–4These keys are not currently enabled (future 
    use). 
    						
    							Getting started
    Vivid7/Vivid7 PRO Users Manual41
    FC092326-03
    The alphanumeric keyboard
    Key Description
    Displays the on-line version of the user manual.
    Displays the configuration dialog box, allowing 
    user configuration of various settings on the 
    scanner. Some settings are configured for each 
    application, press 
    APPL. to access to 
    application-specific settings.
    Displays the DICOM spooler window. The 
    DICOM spooler is used for checking the current 
    job’s status when a job is saved or when the total 
    spooler status on the right of the Archive 
    windows displays an error.
    Displays the available body marks for the current 
    application.
    Erases all previously typed annotations (and 
    body marks.
    Activates a cursor for selection of a single 
    annotation to be deleted from an image.
    Displays an arrow that can be used to point at a 
    specific structure in the image. 
    						
    							Getting started
    42Vivid7/Vivid7 PRO Users Manual
    FC092326-03
    Enables text annotation to be inserted on the 
    image. The annotations can be typed or selected 
    from a (configurable) menu. Key Description 
    						
    							Getting started
    Vivid7/Vivid7 PRO Users Manual43
    FC092326-03
    The Scanning screen
     Figure 1-9: The scanning screen
    1. Current patient data
    2. Institution
    3. Date & time
    4. Operator ID
    5. Probe
    6. Application
    7. Mechanical & Thermal Index
    8. VCR counter (replay)
    9. VCR status
    10. Date & time
    11. Heart rate
    12. Parameter window
    13. Frame counter and timer
    14. Soft menu window
    15. Pull-down soft menu16. Trackball assignment
    17. Status bar
    18. Prompt/Status information
    19. Clipboard
    20. Service and iLinq (future use)
    21. Caps on/off
    22. Measurement result table (measurement mode)
    23. Probe orientation marker
    24. Scanplane indicator (for TE probe)
    25. Greyscale/Color bar
    26. Measurement
    27. Physiological traces (ECG, Phono, Resp)
    28. Focal zone and depth scale
    1710259113468
    12
    13
    15
    14
    162017182119
    24
    25
    2322
    27
    26
    28 
    						
    							Getting started
    44Vivid7/Vivid7 PRO Users Manual
    FC092326-03
    The scanning screen is divided in several areas as follows:
    The title bar
    From the left:
    The patient infor-
    mation displayed on 
    the Title bar is con-
    figurable (see 
    page 437).Patient Information
    Displays the information that uniquely identifies the patient, 
    such as patient name, identification number and birth date. 
    This information is entered in the New patient window, as 
    described on page 49.
    Institution name
    The institution name is entered from the configuration package. 
    See page 443 for more detailed information.
    Operator ID
    Identification code of the operator. See page 449 for creating 
    operator ID’s.
    Date and time
    Displays the current date and time or for a retrieved image, the 
    date and time at which it was stored.
    Probe and Application
    Displays the currently selected probe and application or for 
    retrieved image the probe and application that were used. See 
    page 53 and page 366 for further information on how to select 
    probe and application.
    Live scanning related information
    Displays, if available, the current values for 
    •  Mechanical Index (MI), for the current active image
    •  Thermal Index (TI), for the current active image
    •  probe temperature (for TE probe)
    Heart rate values 
    greater than 250 
    BPM may not be ac-
    curately displayed.•  Heart rate (HR)
    VCR counter and status
    Displays the VCR counter as it changes in real time, and a 
    status icon, which indicates the current operating status of the 
    VCR. 
    						
    							Getting started
    Vivid7/Vivid7 PRO Users Manual45
    FC092326-03
    Archive Information
    Displays the currently selected patient and image archives.
    Parameters window
    Displays scan mode or application specific parameters. In 
    scanning mode the parameters for the active mode are 
    highlighted. This window also displays zoom information, 
    stress template and image groups in image browser.
    Soft menu window
    Displays the mode specific controls operated from the 4-way 
    rocker on the control panel. The mode-specific menus are 
    described in Chapter 3, ’Scanning Modes’ on page 89. For 
    operating procedure of the 4-way rocker see page 58.
    Clipboard
    Displays the thumbnail images representing the acquired data 
    during the current examination.
    The status bar
    Consists of three information fields as follows:
    Caps on/off indicator
    Located on the left side of the status bar, the word CAPS is 
    highlighted when the caps lock function is on. The caps 
    function is activated by pressing 
    CAPS LOCK key on the 
    alphanumeric keyboard.
    Prompt/status field
    Displays system messages or prompts the user for actions.
    Trackball assignments fields
    Displays the available assignments of the trackball. The current 
    assignment is highlighted.
    The acquisition window
    Displays the ultrasound image with relevant indicators such as 
    depth, focus, probe orientation marker, physiological 
    traces...etc.  
    						
    							Getting started
    46Vivid7/Vivid7 PRO Users Manual
    FC092326-03
    Footswitch operation
    The footswitch is used to free the hands of common key 
    operations, such as select keys, video recording, etc. The three 
    switches have different function assignments depending on the 
    current application (see page 400).
    Connecting the footswitch
    1. Connect the footswitch to the input marked   on the 
    External I/O panel (see Figure 1-10).
     Figure 1-10: The Footswitch connector on the External I/O Panel 
    						
    All GE manuals Comments (0)