    							•SNMPAlertDestination(s)—TheIPaddressesorFQDNsofuptothreeremotemanagement
    systemsthatwillreceiveSNMPalertsfromiLO.
    NOTE:Typically,youentertheHPSIMserverconsoleIPaddressinoneoftheSNMP
    AlertDestination(s)boxes.
    WhenSNMPAlertDestinationsareconfiguredusingFQDN,andDNSprovidesboth
    IPv4andIPv6addressesforthoseFQDNs,iLOwillsendtrapstotheaddressspecified
    bytheiLOClientApplicationsuseIPv6firstsettingonthenetworkconfigurationIPv6
    page.IfiLOClientApplicationsuseIPv6firstisselected,trapswillbesenttoIPv6addresses
    (whenavailable).WheniLOClientApplicationsuseIPv6firstisnotselected,trapswill
    besenttoIPv4addresses(whenavailable).
    •SNMPPort—TheportusedforSNMPcommunications.Thisvalueisread-only,butcan
    bemodifiedontheAdministration→AccessSettingspage.
    ClicktheSNMPPortlinktonavigatetotheAdministration→AccessSettingspage.For
    moreinformation,see“ConfiguringiLOaccesssettings”(page57).
    5.ClickApplytosavetheconfiguration.
    ConfiguringSNMPv3Users
    iLO41.20orlatersupportsSNMPv3authenticationwhenyouuseAgentlessManagement.
    ThefollowingsecurityfeaturesofSNMPv3enablesecuredatacollectionfromSNMPagents:
    •Messageintegritypreventstamperingduringpackettransmission.
    •Encryptionpreventspacketsnooping.
    •Authenticationensuresthatpacketsarefromavalidsource.
    Bydefault,SNMPv3supportstheUser-basedSecurityModel.Withthismodel,securityparameters
    areconfiguredatboththeagentlevelandthemanagerlevel.Messagesexchangedbetweenthe
    agentandthemanageraresubjecttoadataintegritycheckanddataoriginauthentication.
    iLOsupportsthreeuserprofilesinwhichyoucansettheSNMPv3USMparameters.
    ToeditSNMPv3userprofiles:
    1.NavigatetotheAdministration→Managementpage.
    2.ClicktheSNMPSettingstabandscrolltotheSNMPv3Userssection.
    3.SelectauserprofileintheSNMPv3Userssection,andthenclickEdit.
    TheiLOwebinterfaceupdatestoshowtheSNMPv3useroptions.
    ConfiguringiLOManagementsettings111 
    						
    							4.Enterthefollowinginformation:
    •SecurityName—Theuserprofilename.Enteranalphanumericstringof1to32characters.
    •AuthenticationProtocol—Setsthemessagedigestalgorithmtouseforencodingthe
    authorizationpassphrase.Themessagedigestiscalculatedoveranappropriateportion
    ofanSNMPmessage,andisincludedaspartofthemessagesenttotherecipient.Select
    MD5orSHA.
    •AuthenticationPassphrase—Setsthepassphrasetouseforsignoperations.Enteravalue
    of8to49characters.
    •PrivacyProtocol—Setstheencryptionalgorithmtouseforencodingtheprivacypassphrase.
    AportionofanSNMPmessageisencryptedbeforetransmission.SelectAESorDES.
    •PrivacyPassphrase—Setsthepassphraseusedforencryptoperations.Enteravalueof
    8to49characters.
    5.ClickApplytosavetheuserprofile.
    ConfiguringtheSNMPv3EngineID
    TheSNMPv3EngineIDsetstheuniqueidentifierofanSNMPenginebelongingtoanSNMPagent
    entity.YoucanconfigurethisvaluewhenAgentlessManagementisselected.
    ToconfiguretheSNMPv3EngineID:
    1.NavigatetotheAdministration→Managementpage.
    2.ClicktheSNMPSettingstabandscrolltotheSNMPv3Userssection.
    3.EnteravalueintheSNMPv3EngineIDbox.
    Thisvaluemustbeahexadecimalstringof6to32characters,andmustbeanevennumber
    ofcharacters,excludingthepreceding0x(forexample,0x01020304abcdef).
    4.ClickApply.
    ConfiguringSNMPalerts
    YoucanconfiguretheTrapSourceIdentifier,iLOSNMPalerts,forwardingofInsightManagement
    AgentSNMPalerts,ColdStartTrapbroadcast,andSNMPv1traps.
    ToconfigureSNMPalerts:
    1.NavigatetotheAdministration→Managementpage.
    2.ClicktheSNMPSettingstabandscrolltotheSNMPAlertssection.
    112ConfiguringiLO 
    						
    							3.ConfiguretheTrapSourceIdentifierbyselectingiLOHostnameorOSHostname.
    ThissettingdeterminesthehostnamethatisusedintheSNMP-definedsysNamevariable
    wheniLOgeneratesSNMPtraps.ThedefaultsettingisiLOHostname.
    NOTE:ThehostnameisanOSconstructanddoesnotremainpersistentwiththeserver
    whentheharddrivesaremovedtoanewserverplatform.TheiLOsysName,however,remains
    persistentwiththesystemboard.
    4.Enableordisablethefollowingalerttypes:
    •iLOSNMPAlerts—AlertconditionsthatiLOdetectsindependentlyofthehostoperating
    systemcanbesenttospecifiedSNMPalertdestinations,suchasHPSIM.Ifthisoption
    isdisabled,notrapswillbesenttotheconfiguredSNMPalertdestinations.
    •ForwardInsightManagerAgentSNMPAlerts—Alertconditionsdetectedbythehost
    managementagentscanbeforwardedtoSNMPalertdestinationsthroughiLO.These
    alertsaregeneratedbytheInsightManagementAgents,whichareavailableforeach
    supportedoperatingsystem.InsightManagementAgentsmustbeinstalledonthehost
    servertoreceivethesealerts.
    •ColdStartTrapBroadcast—Whenthisoptionisenabled,ColdStartTrapisbroadcastto
    asubnetbroadcastaddressifnovalidtrapdestinationsareconfigured.
    TheColdStartTrapisbroadcastwhenanyofthefollowingconditionsismet:
    ◦SNMPAlertDestinationsarenotconfigured.
    ◦iLOfailedtoresolvealloftheSNMPAlertDestinationstoIPaddresses.
    ThesubnetbroadcastaddressforanIPv4hostisobtainedbyperformingabitwiselogical
    ORoperationbetweenthebitcomplementofthesubnetmaskandthehostIPaddress.
    Forexample,thehost192.168.1.1,whichhasthesubnetmask255.255.252.0,has
    thebroadcastaddress192.168.1.1 | 0.0.3.255 = 192.168.3.255.
    •SNMPv1Traps—Whenenabled,SNMPv1trapsaresenttotheremotemanagement
    systemsconfiguredintheSNMPAlertDestination(s)boxes.
    5.Optional:ClickSendTestAlerttogenerateatestalertandsendittotheTCP/IPaddressesin
    theSNMPAlertDestination(s)boxes.
    TestalertsincludeanInsightManagementSNMPtrap,andareusedtoverifythenetwork
    connectivityofiLOinHPSIM.OnlyuserswiththeConfigureiLOSettingsprivilegecansend
    testalerts.
    Afterthealertisgenerated,aconfirmationdialogboxopens.ChecktheHPSIMconsolefor
    receiptofthealert.
    6.ClickApplytosavetheconfiguration.
    UsingtheAMSControlPaneltoconfigureSNMPandSNMPalerts(Windowsonly)
    1.OpentheAgentlessManagementServiceControlPanel.
    2.ClicktheSNMPtab.
    ConfiguringiLOManagementsettings113 
    						
    							3.UpdatetheSNMPsettings.
    Foradescriptionoftheavailablesettings,see“ConfiguringSNMPsettings”(page109)and
    “ConfiguringSNMPalerts”(page112).
    4.Optional:ClickSendTestTraptogenerateatestalertandsendittotheTCP/IPaddressesin
    theTrapDestination(s)boxes.
    TestalertsincludeanInsightManagementSNMPtrapandareusedtoverifythenetwork
    connectivityofiLOinHPSIM.OnlyusersthathavetheConfigureiLOSettingsprivilegecan
    sendtestalerts.
    Afterthealertisgenerated,aconfirmationdialogboxopens.ChecktheHPSIMconsolefor
    receiptofthealert.
    5.ClickApplytosavetheconfiguration.
    SNMPtraps
    Table3(page114)liststheSNMPtrapsthatyoucangeneratewithiLOandHPProLiantGen8and
    Gen9servers.
    FormoreinformationabouttheseSNMPtraps,seethefollowingfilesintheInsightManagement
    MIBupdatekitforHPSIM:
    •cpqida.mib
    •cpqhost.mib
    •cpqhlth.mib
    •cpqsm2.mib
    •cpqide.mib
    •cpqscsi.mib
    •cpqnic.mib
    •cpqstsys.mib
    •cpqstdeq.mib
    Table3SNMPtraps
    DescriptionSNMPtrapname
    SNMPhasbeeninitialized,thesystemhascompletedPOST,or
    AMShasstarted.
    ColdStartTrap0
    SNMPhasdetectedanauthenticationfailure.AuthenticationFailureTrap4
    114ConfiguringiLO 
    						
    							Table3SNMPtraps(continued)
    DescriptionSNMPtrapname
    Anuncorrectablemachinecheckexceptionhasbeendetectedin
    aprocessor.
    cpqSeCpuStatusChange1006
    AchangehasbeendetectedinthestatusoftheSmartArray
    controller.
    cpqDa6CntlrStatusChange3033
    AchangehasbeendetectedinthestatusofaSmartArraylogical
    drive.
    cpqDa6LogDrvStatusChange3034
    AchangehasbeendetectedinthestatusofaSmartArraycache
    module.
    cpqDa6AccelStatusChange3038
    TheSmartArraycachemodulehaslostbackuppower.cpqDa6AccelBadDataTrap3039
    TheSmartArraycachemodulebackuppowerhasfailed.cpqDa6AccelBatteryFailed3040
    AchangehasbeendetectedinthestatusofaSmartArrayphysical
    drive.
    cpqDa7PhyDrvStatusChange3046
    AchangehasbeendetectedinthestatusofaSmartArrayspare
    drive.
    cpqDa7SpareStatusChange3047
    AchangehasbeendetectedintheSSDwearstatusofaSmart
    Arrayphysicaldrive.
    cpqDaPhyDrvSSDWearStatusChange3049
    Theserverwasshutdownduetoathermalanomalyandisnow
    operational.
    cpqHe3ThermalConfirmation6026
    OneormorePOSTerrorshaveoccurred.cpqHe3PostError6027
    Thefault-tolerantpowersupplieshavelostredundancyforthe
    specifiedchassis.
    cpqHe3FltTolPowerRedundancyLost6032
    Afault-tolerantpowersupplyhasbeeninserted.cpqHe3FltTolPowerSupplyInserted6033
    Afault-tolerantpowersupplyhasbeenremoved.cpqHe3FltTolPowerSupplyRemoved6034
    Thefault-tolerantfanconditionhasbeensettoDegraded.cpqHe3FltTolFanDegraded6035
    Thefault-tolerantfanconditionhasbeensettoFailed.cpqHe3FltTolFanFailed6036
    Thefault-tolerantfanshavelostredundancy.cpqHe3FltTolFanRedundancyLost6037
    Afault-tolerantfanhasbeeninserted.cpqHe3FltTolFanInserted6038
    Afault-tolerantfanhasbeenremoved.cpqHe3FltTolFanRemoved6039
    ThetemperaturestatushasbeensettoDegraded,andthe
    temperatureisoutsidethenormaloperatingrange.Depending
    onthesystemconfiguration,thissystemmightbeshutdown.
    cpqHe3TemperatureDegraded6041
    ThetemperaturestatushasbeensettoOK.cpqHe3TemperatureOk6042
    Thefault-tolerantpowersupplyconditionhasbeenresettoOK.cpqHe4FltTolPowerSupplyOk6048
    Thefault-tolerantpowersupplyconditionhasbeensettoDegraded.cpqHe4FltTolPowerSupplyDegraded6049
    Thefault-tolerantpowersupplyconditionhasbeensettoFailed.cpqHe4FltTolPowerSupplyFailed6050
    TheAdvancedMemoryProtectionsubsystemhasdetecteda
    memoryfault.MirroredMemoryhasbeenactivated.
    cpqHeResilientMemMirroredMemoryEngaged6051
    Thefault-tolerantpowersupplieshavereturnedtoaredundant
    state.
    cpqHe3FltTolPowerRedundancyRestore6054
    Thefault-tolerantfanshavereturnedtoaredundantstate.cpqHe3FltTolFanRedundancyRestored6055
    Memoryerrorshavebeencorrected,butthememorymodule
    shouldbereplaced.
    cpqHe5CorrMemReplaceMemModule6064
    ConfiguringiLOManagementsettings115 
    						
    							Table3SNMPtraps(continued)
    DescriptionSNMPtrapname
    Thefault-tolerantpowersupplyinthespecifiedchassisandbay
    reportedACpowerloss.
    cpqHe4FltTolPowerSupplyACpowerloss6069
    TheHPSmartStoragebatteryhasfailed.cpqHeSysBatteryFailed6070
    TheHPSmartStoragebatteryhasbeenremoved.cpqHeSysBatteryRemoved6071
    Achangehasbeendetectedinthefanstatusofthestoragesystem.cpqSs6FanStatusChange8029
    Achangehasbeendetectedinthetemperaturestatusofthe
    storagesystem.
    cpqSs6TempStatusChange8030
    Achangehasbeendetectedinthepowerstatusofthestorage
    system.
    cpqSs6PwrSupplyStatusChange8031
    Theserverpowerhasbeenreset.cpqSm2ServerReset9001
    Themaximumunauthorizedloginattemptthresholdhasbeen
    exceeded.
    cpqSm2UnauthorizedLoginAttempts9003
    iLO4hasdetectedaSelfTestError.cpqSm2SelfTestError9005
    iLO4hasdetectedthatthesecurityoverridejumperhasbeen
    toggledtotheengagedposition.
    cpqSm2SecurityOverrideEngaged9012
    iLO4hasdetectedthatthesecurityoverridejumperhasbeen
    toggledtothedisengagedposition.
    cpqSm2SecurityOverrideDisengaged9013
    Theserverhasbeenpoweredon.cpqSm2ServerPowerOn9017
    Theserverhasbeenpoweredoff.cpqSm2ServerPowerOff9018
    Arequestwasmadetopowerontheserver,buttheservercould
    notbepoweredonbecauseofafailurecondition.
    cpqSm2ServerPowerOnFailure9019
    CommunicationwithInsightRemoteSupportorInsightOnlinehas
    failed.
    cpqSm2IrsCommFailure9020
    Generictrap.VerifiesthattheSNMPconfiguration,clientSNMP
    console,andnetworkareoperatingcorrectly.Youcanusethe
    cpqHo2GenericTrap11003
    iLOwebinterfacetogeneratethisalerttoverifyreceiptofthealert
    ontheSNMPconsole.
    Apowerthresholdhasbeenexceeded.cpqHo2PowerThresholdTrap11018
    Achangeinthehealthstatusoftheserverhasoccurred.cpqHoMibHealthStatusArrayChangeTrap11020
    AMSdetectedachangeinthestatusofanSASorSATAphysical
    drive.
    cpqSasPhyDrvStatusChange5022
    AMSdetectedachangeinthestatusofanATAdiskdrive.cpqIdeAtaDiskStatusChange14004
    AMSdetectedthatconnectivitywasrestoredtoalogicalnetwork
    adapter.
    cpqNic3ConnectivityRestored18011
    AMSdetectedthatthestatusofalogicalnetworkadapterchanged
    toFailed.
    cpqNic3ConnectivityLost18012
    ConfiguringInsightManagementintegration
    1.NavigatetotheAdministration→Managementpage.
    2.ClicktheSNMPSettingstabandscrolltotheInsightManagementIntegrationsection.
    116ConfiguringiLO 
    						
    							3.ConfiguretheHPSystemManagementHomepage(HPSMH)FQDN/IPAddress.
    ThisvaluesetsthebrowserdestinationoftheInsightAgentlinkoniLOpages.
    EntertheFQDNorIPaddressofthehostserver.Theprotocol(https://)andportnumber
    (:2381)areaddedautomaticallytotheIPaddressorDNSnametoallowaccessfromiLO.
    IftheURLissetthroughanothermethod(forexample,HPQLOCFG),clickthebrowserrefresh
    buttontodisplaytheupdatedURL.
    4.SelecttheLevelofDataReturned.
    ThissettingcontrolsthecontentofananonymousdiscoverymessagereceivedbyiLO.The
    informationreturnedisusedforHPSIMHTTPidentificationrequests.Thefollowingoptions
    areavailable:
    •Enabled(iLO+ServerAssociationData)(default)—EnablesHPSIMtoassociatethe
    managementprocessorwiththehostserver,andprovidessufficientdatatoenable
    integrationwithHPSIM.
    •Disabled(NoResponsetoRequest)—PreventsiLOfromrespondingtoHPSIMrequests.
    5.Optional:ClickViewXMLReplytoviewtheresponsethatisreturnedtoHPSIMwhenit
    requestsiLOmanagementprocessoridentificationbyusingtheprovidedaddress.
    6.ClickApplytosavethechanges.
    FormoreinformationabouttheInsightManagementAgents,navigatetotheInformation→Insight
    Agentpage.
    ConfiguringAlertMailsettings
    iLOAlertMailenablesyoutoconfigureiLOtosendalertconditionsdetectedindependentlyofthe
    hostoperatingsystemtoaspecifiedemailaddress.iLOmailalertsincludemajorhostsystem
    events.
    YoumusthavetheConfigureiLOSettingsprivilegetochangethesesettings.
    ThisfeatureandmanyothersarepartofaniLOlicensingpackage.Formoreinformationabout
    iLOlicensing,seethefollowingwebsite:http://www.hp.com/go/ilo/licensing.
    ConfiguringiLOManagementsettings117 
    						
    							EnablingAlertMail
    1.NavigatetotheAdministration→Management→AlertMailpage.
    2.SelecttheEnableiLOAlertMailcheckbox.
    3.Enterthefollowinginformation:
    •EmailAddress—ThedestinationemailaddressforiLOemailalerts.Thisstringcanbeup
    to63charactersandshouldbeinstandardemailaddressformat.Youcanenteronly
    oneemailaddress.
    •SenderDomain—Thedomainnamespecifiedinthesender(From)emailaddress.The
    senderemailaddressisformedbyusingtheiLOnameashostname,andthesubject
    stringasdomainname.Ifnodomainnameisspecified,theiLOdomainname,which
    maynotbeacceptedbyallSMTPservers,isused.Thisstringcanbeupto63characters.
    •SMTPPort—TheportthattheSMTPserverwilluseforunauthenticatedSMTPconnections.
    Thedefaultvalueis25.
    •SMTPServer—TheIPaddressorDNSnameoftheSMTPserverortheMSA.Thisserver
    cooperateswiththeMTAtodelivertheemail.Thisstringcanbeupto63characters.
    4.Optional:ClickSendTestAlertMailtosendatestmessagetotheconfiguredemailaddress.
    ThisbuttonisavailableonlywhenAlertMailisenabled.
    5.ClickApplytosavethechanges.
    DisablingAlertMail
    1.NavigatetotheAdministration→Management→AlertMailpage.
    2.CleartheEnableiLOAlertMailcheckbox.
    3.ClickApplytosavethechanges.
    ConfiguringRemoteSyslogsettings
    TheRemoteSyslogfeatureallowsiLOtosendeventnotificationmessagestoSyslogservers.The
    iLOfirmwareRemoteSyslogincludestheIMLandiLOEventLog.
    YoumusthavetheConfigureiLOSettingsprivilegetochangethesesettings.
    ThisfeatureandmanyothersarepartofaniLOlicensingpackage.Formoreinformationabout
    iLOlicensing,seethefollowingwebsite:http://www.hp.com/go/ilo/licensing.
    118ConfiguringiLO 
    						
    							EnablingiLORemoteSyslog
    1.NavigatetotheAdministration→Management→RemoteSyslogpage.
    2.SelecttheEnableiLORemoteSyslogcheckbox.
    3.Enterthefollowinginformation:
    •RemoteSyslogPort—TheportnumberthroughwhichtheSyslogserverislistening.
    Thedefaultvalueis514.
    •RemoteSyslogServer—TheIPaddress,FQDN,IPv6name,orshortnameoftheserver
    runningtheSyslogservice.Thisstringcanbeupto127characters.
    OnLinuxsystems,systemeventsareloggedbyatoolcalledsyslog.Thistoolshouldbe
    installedonallLinuxsystems.Youcansetasyslogserveronaremotesystemthatwill
    actasacentralloggingsystemforiLOsystems.Thisway,iftheiLORemoteSyslogfeature
    isenablediniLO,itcansenditslogstothesyslogserver.
    4.Optional:ClickSendTestSyslogtosendatestmessagetotheconfiguredsyslogserver.
    ThisbuttonisavailableonlywheniLORemoteSyslogisenabled.
    5.ClickApplytosavethechanges.
    DisablingiLORemoteSyslog
    1.NavigatetotheAdministration→Management→RemoteSyslogpage.
    2.CleartheEnableiLORemoteSyslogcheckbox.
    3.ClickApplytosavethechanges.
    Configuringremotesupport
    HPremotesupportoverview
    HPhasdevelopedaserviceandsupportsolutionthatintegratesthefollowing:
    •Anonline,personalizeddashboard(HPInsightOnline)
    •24x7remotesupportwithHPInsightRemoteSupportsoftwareandInsightOnlinedirect
    connectcapability
    WhenyouusetheembeddedRemoteSupportfunctionalitywithanHPProLiantserver,youcan
    choosefromthefollowingconfigurationoptions:
    Configuringremotesupport119 
    						
    							Configurationoptions
    •InsightOnlinedirectconnect—RegisteraservertocommunicatedirectlywithInsightOnline
    withouttheneedtosetupanInsightRemoteSupportcentralizedHostingDeviceinyourlocal
    environment.InsightOnlinewillbeyourprimaryinterfaceforremotesupportinformation.
    InsightOnlineisanHPSupportCenterfeaturethatenablesyoutoviewyourremotelymonitored
    devicesanywhere,anytime.Itprovidesapersonalizeddashboardforsimplifiedtrackingof
    IToperationsandsupportinformation,includingamobiledashboardformonitoringwhen
    youareonthego.Formoreinformation,seehttp://www.hp.com/go/insightonline/info.
    ForHPProLiantGen8servers,thedirectconnectconfigurationisavailableiniLO41.40and
    later.
    ForHPProLiantGen9servers,thedirectconnectconfigurationisavailableiniLO42.00and
    later.
    Figure3(page120)showsthedirectconnectconfigurationwithanHPProLiantserver.
    Figure3InsightOnlinedirectconnect
    •InsightRemoteSupportcentralconnect—RegisteraservertocommunicatewithHPthrough
    anInsightRemoteSupportcentralizedHostingDeviceinyourlocalenvironment.All
    configurationandserviceeventinformationisroutedthroughtheHostingDevice.This
    informationcanbeviewedusingthelocalInsightRSConsoleortheweb-basedviewinInsight
    Online(ifitisenabledinInsightRS).
    ForHPProLiantGen8servers,thecentralconnectconfigurationisavailableiniLO41.10
    andlater.
    ForHPProLiantGen9servers,thecentralconnectconfigurationisavailableiniLO42.00
    andlater.
    Figure4(page120)showsthecentralconnectconfigurationwithanHPProLiantserver.
    Figure4InsightRemoteSupportcentralconnect
    120ConfiguringiLOProLiant serverFirewall ProLiantserverFirewallInsight RS
    Hosting Device  
    						
    All HP manuals Comments (0)

    Related Manuals for HP Ilo 4 User Guide