    							PowerReadings(BLserversonly)
    ThePowerReadingssectionforBLserversincludesthefollowinginformation:
    PresentPowerReading—Themostrecentpowerreadingfromtheserver.
    Althoughthisvalueistypicallyequaltothesumofallactivepowersupplyoutputs,theremightbe
    somesmallvarianceasaresultofreadingtheindividualpowersupplies.Thisvalueisaguideline
    valueandisnotasaccurateasthevaluespresentedonthePowerManagementpages.Formore
    information,see“Viewingserverpowerusage”(page240).
    PowerMicrocontroller(BLserversonly)
    ThePowerMicrocontrollersectionforBLserversincludesthefollowinginformation:
    FirmwareVersion—Thefirmwareversionofthepowermanagementcontroller.Theservermustbe
    poweredonforiLOtodeterminethefirmwareversion.
    HPSmartStorageBattery(Gen9serversonly)
    TheHPSmartStorageBatterysectionincludesthefollowinginformation:
    •Index—Thebatteryindexnumber.
    •Present—Whetherabatteryisinstalled.
    •Status—Thebatterystatus.
    •Model—Thebatterymodelnumber.
    •Spare—Thepartnumberofthesparebattery.
    •Serial—Thebatteryserialnumber.
    •Capacity—Thebatterycapacity.
    •Firmware—Theinstalledbatteryfirmwareversion.
    Viewingprocessorinformation
    TheProcessorInformationpagedisplaystheavailableprocessorslots,thetypeofprocessorinstalled
    ineachslot,andasummaryoftheprocessorsubsystem.
    Iftheserverispoweredoff,thesystemhealthinformationonthispageiscurrentasofthelast
    poweroff.HealthinformationisupdatedonlywhentheserverispoweredonandPOSTiscomplete.
    ToviewtheProcessorInformationpage,navigatetotheInformation→SystemInformationpage,
    andthenclicktheProcessorstab.
    ViewingiLOsysteminformation161 
    						
    							Thefollowinginformationisdisplayed:
    •ProcessorName—Thenameoftheprocessor
    •ProcessorStatus—Thehealthstatusoftheprocessor
    •ProcessorSpeed—Thespeedoftheprocessor
    •ExecutionTechnology—Informationabouttheprocessorcoresandthreads
    •MemoryTechnology—Theprocessormemorycapabilities
    •InternalL1cache—TheL1cachesize
    •InternalL2cache—TheL2cachesize
    •InternalL3cache—TheL3cachesize
    Viewingmemoryinformation
    TheMemoryInformationpagedisplaysasummaryofthesystemmemory.Whenserverpoweris
    off,AMPdataisunavailable,andonlymemorymodulespresentatPOSTaredisplayed.
    Iftheserverispoweredoff,thesystemhealthinformationonthispageiscurrentasofthelast
    poweroff.HealthinformationisupdatedonlywhentheserverispoweredonandPOSTiscomplete.
    Toviewmemoryinformation,navigatetotheInformation→SystemInformationpage,andthen
    clicktheMemorytab.
    162UsingiLO 
    						
    							AdvancedMemoryProtection
    Thissectiondisplaysthefollowinginformation:
    •AMPModeStatus—ThestatusoftheAMPsubsystem.Thefollowingstatesaresupported:
    Other/Unknown—ThesystemdoesnotsupportAMP,orthemanagementsoftwarecannot
    determinethestatus.
    ◦
    ◦NotProtected—ThesystemsupportsAMP,butthefeatureisdisabled.
    ◦Protected—ThesystemsupportsAMP.Thefeatureisenabledbutnotengaged.
    ◦Degraded—Thesystemwasprotected,butAMPisengaged.Therefore,AMPisnolonger
    available.
    ◦DIMMECC—ThesystemisprotectedbyDIMMECConly.
    ◦Mirroring—ThesystemisprotectedbyAMPinthemirroredmode.NoDIMMfaultshave
    beendetected.
    ◦DegradedMirroring—ThesystemisprotectedbyAMPinthemirroredmode.Oneor
    moreDIMMfaultshavebeendetected.
    ◦On-lineSpare—ThesystemisprotectedbyAMPinthehotsparemode.NoDIMMfaults
    havebeendetected.
    ◦DegradedOn-lineSpare—ThesystemisprotectedbyAMPinthehotsparemode.One
    ormoreDIMMfaultshavebeendetected.
    ◦RAID-XOR—ThesystemisprotectedbyAMPintheXORmemorymode.NoDIMMfaults
    havebeendetected.
    ◦DegradedRAID-XOR—ThesystemisprotectedbyAMPintheXORmemorymode.One
    ormoreDIMMfaultshavebeendetected.
    ◦AdvancedECC—ThesystemisprotectedbyAMPintheAdvancedECCmode.
    ◦DegradedAdvancedECC—ThesystemisprotectedbyAMPintheAdvancedECCmode.
    OneormoreDIMMfaultshavebeendetected.
    ViewingiLOsysteminformation163 
    						
    							◦LockStep—ThesystemisprotectedbyAMPintheLockStepmode.
    ◦DegradedLockStep—ThesystemisprotectedbyAMPintheLockStepmode.Oneormore
    DIMMfaultshavebeendetected.
    •ConfiguredAMPMode—TheactiveAMPmode.Thefollowingmodesaresupported:
    None/Unknown—ThemanagementsoftwarecannotdeterminetheAMPfaulttolerance,
    orthesystemisnotconfiguredforAMP.
    ◦
    ◦On-lineSpare—Asinglesparebankofmemoryissetasideatboottime.IfenoughECC
    errorsoccur,thesparememoryisactivatedandthememorythatisexperiencingthe
    errorsisdisabled.
    ◦Mirroring—Thesystemisconfiguredformirroredmemoryprotection.Allmemorybanks
    areduplicatedinmirroredmemory,asopposedtoonlyoneforonlinesparememory.If
    enoughECCerrorsoccur,thesparememoryisactivatedandthememorythatis
    experiencingtheerrorsisdisabled.
    ◦RAID-XOR—ThesystemisconfiguredforAMPwiththeXORengine.
    ◦AdvancedECC—ThesystemisconfiguredforAMPwiththeAdvancedECCengine.
    ◦LockStep—ThesystemisconfiguredforAMPwiththeLockStepengine.
    •OnlineSpare(RankSparing)—ThesystemisconfiguredforOnlineSpareRankAMP.
    •OnlineSpare(ChannelSparing)—ThesystemisconfiguredforOnlineSpareChannelAMP.
    •IntersocketMirroring—ThesystemisconfiguredformirroredintersocketAMPbetweenthe
    memoryoftwoprocessorsorboards.
    •IntrasocketMirroring—ThesystemisconfiguredformirroredintrasocketAMPbetweenthe
    memoryofasingleprocessororboard.
    •SupportedAMPModes—Thefollowingmodesaresupported:
    RAID-XOR—ThesystemcanbeconfiguredforAMPusingtheXORengine.◦
    ◦DualBoardMirroring—Thesystemcanbeconfiguredformirroredadvancedmemory
    protectioninadualmemoryboardconfiguration.Themirroredmemorycanbeswapped
    withmemoryonthesamememoryboardorwithmemoryonthesecondmemoryboard.
    ◦SingleBoardMirroring—Thesystemcanbeconfiguredformirroredadvancedmemory
    protectioninasinglememoryboard.
    ◦AdvancedECC—ThesystemcanbeconfiguredforAdvancedECC.
    ◦Mirroring—ThesystemcanbeconfiguredformirroredAMP.
    ◦On-lineSpare—ThesystemcanbeconfiguredforonlinespareAMP.
    ◦LockStep—ThesystemcanbeconfiguredforLockStepAMP.
    ◦OnlineSpare(RankSparing)—ThesystemcanbeconfiguredforOnlineSpareRankAMP.
    ◦OnlineSpare(ChannelSparing)—ThesystemcanbeconfiguredforOnlineSpareChannel
    AMP.
    ◦IntersocketMirroring—ThesystemcanbeconfiguredformirroredintersocketAMPbetween
    thememoryoftwoprocessorsorboards.
    164UsingiLO 
    						
    							◦IntrasocketMirroring—ThesystemcanbeconfiguredformirroredintrasocketAMPbetween
    thememoryofasingleprocessororboard.
    ◦None—ThesystemcannotbeconfiguredforAMP.
    MemorySummary
    ThissectionshowsasummaryofthememorythatwasinstalledandoperationalatPOST.
    •Location—Theslotorprocessoronwhichthememoryboard,cartridge,orriserisinstalled.
    Possiblevaluesfollow:
    ◦SystemBoard—Thereisnoseparatememoryboardslot.AllDIMMsareinstalledonthe
    motherboard.
    ◦BoardNumber—Thereisamemoryboardslotavailable.AllDIMMsareinstalledonthe
    memoryboard.
    ◦ProcessorNumber—TheprocessoronwhichthememoryDIMMsareinstalled.
    ◦RiserNumber—TheriseronwhichthememoryDIMMsareinstalled.
    •NumberofSockets—Thenumberofmemorymodulesocketspresentonthememoryboard,
    cartridge,orriser.
    •TotalMemory—Thesizeofthememoryforthisboard,cartridge,orriser,includingmemory
    recognizedbytheoperatingsystemandmemoryusedforspare,mirrored,orXOR
    configurations.
    •OperatingFrequency—Thefrequencyatwhichthememoryonthememoryboard,cartridge,
    orriseroperates.
    •OperatingVoltage—Thevoltageatwhichthememoryonthememoryboard,cartridge,or
    riseroperates.
    MemoryDetails
    ThissectionshowsthememorymodulesonthehostthatwereinstalledandoperationalatPOST.
    Unpopulatedmodulepositionsarealsolisted.Variousresilientmemoryconfigurationscanchange
    theactualmemoryinventoryfromwhatwassampledatPOST.Insystemsthathaveahighnumber
    ofmemorymodules,allmodulepositionsmightnotbelisted.
    Bydefault,emptymemorysocketsarehidden.Toviewtheemptymemorysockets,clickshow
    emptysockets.Whenemptymemorysocketsaredisplayed,clickhideemptysocketstohidethem.
    •MemoryLocation—Theslotorprocessoronwhichthememorymoduleisinstalled.
    •Socket—Thememorymodulesocketnumber.
    •Status—Thememorymodulestatusandwhetherthemoduleisinuse.
    •HPSmartMemory—WhetherthememorymoduleisHPSmartMemory.PossiblevaluesareYes
    andNo.Ifnomemorymoduleisinstalled,thevalueN/Aisdisplayed.
    IfthevalueNoisdisplayed,thelistedmoduleisnotanHPSmartMemorymodule.Thememory
    modulewillfunction,butithasnowarranty,anditmightnotperformaswellasanHP
    SmartMemorymodule.
    FormoreinformationaboutHPSmartMemory,seehttp://www.hp.com/go/memory.
    •PartNumber—Thememorymodulepartnumber.
    NOTE:ThisvalueisdisplayedonlyforHPSmartMemorymodules.
    ViewingiLOsysteminformation165 
    						
    							•Type—Thetypeofmemoryinstalled.Possiblevaluesfollow:
    Other—Memorytypecannotbedetermined.◦
    ◦Board—Memorymoduleispermanentlymounted(notmodular)onasystemboardor
    memoryexpansionboard.
    ◦CPQsinglewidthmodule
    ◦CPQdoublewidthmodule
    ◦SIMM
    ◦PCMCIA
    ◦Compaq-specific
    ◦DIMM
    ◦SmalloutlineDIMM
    ◦RIMM
    ◦SRIMM
    ◦FB-DIMM
    ◦DIMMDDR
    ◦DIMMDDR2
    ◦DIMMDDR3
    ◦DIMMDDR4(Gen9serversonly)
    ◦FB-DIMMDDR2
    ◦FB-DIMMDDR3
    ◦N/A—Memorymoduleisnotpresent.
    •Size—Thesizeofthememorymodule,inMB.
    •MaximumFrequency—Themaximumfrequencyatwhichthememorymodulecanoperate.
    •MinimumVoltage—Theminimumvoltageatwhichthememorymodulecanoperate.
    •Ranks—Thenumberofranksinthememorymodule.
    •Technology—Thememorymoduletechnology.Possiblevaluesfollow:
    Unknown—Memorytechnologycannotbedetermined.◦
    ◦N/A—Memorymoduleisnotpresent.
    ◦FastPage
    ◦EDO
    ◦BurstEDO
    ◦Synchronous
    ◦RDRAM
    166UsingiLO 
    						
    							◦RDIMM
    ◦UDIMM
    ◦LRDIMM
    Viewingnetworkinformation
    TheNICInformationpagedisplaysread-onlyinformationabouttheintegratedandadd-inNICs.
    Iftheserverispoweredoff,thesystemhealthinformationonthispageiscurrentasofthelast
    poweroff.HealthinformationisupdatedonlywhentheserverispoweredonandPOSTiscomplete.
    TheserverIPaddress,add-innetworkadapters,andserverNICstatusaredisplayedonlyifthe
    AgentlessManagementServiceisinstalledandrunningontheserver.
    ToviewNICinformation,navigatetotheInformation→SystemInformationpage,andthenclick
    theNetworktab.
    Thefollowinginformationisdisplayed:
    •DeviceType—Thedevicetypeisoneofthefollowing:
    iLO4—ThisdevicetypeisassignedtotheiLODedicatedNetworkPortoriLOShared
    NetworkPort.UserswhohavetheConfigureiLOSettingsprivilegecanconfiguretheiLO
    ◦
    NICsettingsontheGeneraltaboftheNetwork→iLODedicatedNetworkPortor
    Network→SharedNetworkPortpage.
    ◦NIC—ThisdevicetypeindicatesNICorLANadaptercomponentsembeddedintheserver
    oraddedaftermanufacturing.BecausesystemNICsaredirectlyavailabletotheserver
    hostoperatingsystem,theiLOfirmwarecannotdirectlyobtaincurrentIPaddresses(or
    otherconfigurationsettings)forthesedevices.
    •NetworkPort—Theconfigurednetworkport.
    •Location—ThelocationoftheNICadapteronthesystemboard.
    •MACAddress—TheportMACaddress.
    •IPAddress—ThehostIPaddress.
    •Description—AdescriptionoftheNIC.
    •Status—TheNICstatus.
    ViewingiLOsysteminformation167 
    						
    							Viewingstorageinformation
    TheStorageInformationpagedisplaysinformationaboutHPSmartArraycontrollers,drive
    enclosures,theattachedlogicaldrives,andthephysicaldrivesthatconstitutethelogicaldrives.
    Iftheserverispoweredoff,thesystemhealthinformationonthispageiscurrentasofthelast
    poweroff.HealthinformationisupdatedonlywhentheserverispoweredonandPOSTiscomplete.
    Theinformationdisplayedonthispagedependsonyourstorageconfiguration.Somestorage
    configurationswillnotdisplayinformationforeverycategory.
    Toexpandorcollapsethedata,clickExpandAllorCollapseAll,respectively.
    Toviewstorageinformation:
    1.NavigatetotheInformation→SystemInformationpage.
    2.ClicktheStoragetab.
    3.Selectoneofthefollowingoptions:
    •LogicalView—Selectthisoptiontoviewconfiguredlogicaldrivesandassociatedphysical
    drives.Thisviewdoesnotshowphysicaldrivesthatarenotconfiguredaspartofan
    array,orsparedrives.
    •PhysicalView—Selectthisoptiontoviewphysicaldrives.Thisviewdoesnotshowlogical
    drives.
    AdescriptionofeachsectionontheStorageInformationpagefollows.
    Controllers
    ThissectionprovidesinformationabouttheHPSmartArraycontrollers.
    Thetop-levelcontrollerstatusisacombinationofthecontrollerhardwarestatusandthestatusof
    cachemodules,enclosures,andphysical,logical,andsparedrivesassociatedwiththecontroller.
    IfthecontrollerhardwarestatusisOK,andanyassociatedhardwarehasafailure,thetop-level
    controllerstatuschangestoMajorWarningorDegraded,dependingonthefailuretype.Ifthe
    controllerhardwarehasaFailedstatus,thetop-levelcontrollerstatusisFailed.
    ThefollowinginformationisdisplayedforeachHPSmartArraycontroller:
    •Controllerlocation—Slotnumberorsystemboard
    •Controllerstatus—Controllerhardwarestatus(OKorFailed)
    •Controllerserialnumber
    •Controllermodelnameandnumber
    •Controllerfirmwareversion
    •Cachemodulestatus
    •Cachemoduleserialnumber
    •Cachemodulememory
    168UsingiLO 
    						
    							Thefollowingstatusinformationisdisplayedforcontrollersthatsupportencryption:
    •EncryptionStatus—Thefollowingvaluesarepossible:
    Enabled◦
    ◦NotEnabled
    ◦Enabled—LocalMode—Thisvalueisdisplayedwhenyoudonotusearemotekey
    managementserver.
    •EncryptionASICStatus—IndicateswhethertheASICencryptionselftestsforthecontroller
    passedorfailed.Afailedstatusindicatesthatthecontrollerisnotencrypted.
    •EncryptionCriticalSecurityParameterNVRAMStatus—Indicateswhetherthecontroller
    successfullydetectedthecriticalsecurityparameterNVRAM.Afailedstatusmeansthatthe
    controllerisnotencrypted.
    NOTE:TheencryptionsettingsforanHPSmartArraycontrollercanbeconfiguredbyusingthe
    HPSmartStorageAdministratorsoftware.Forinstructions,seetheHPSmartStorageAdministrator
    documentation.
    DriveEnclosures
    ThissectionprovidesinformationaboutthedriveenclosuresattachedtoanHPSmartArray
    controller.
    Thefollowinginformationislistedforeachdriveenclosure:
    •Enclosureportandboxnumbers
    •Enclosurestatus
    •Numberofdrivebays
    •Serialnumber
    •Modelnumber
    •Firmwareversion
    Someenclosuresdonothaveallofthelistedproperties,andsomestorageconfigurationsdonot
    havedriveenclosures.
    LogicalDrives
    ThissectionisavailablewhentheLogicalViewoptionisselectedontheSystemInformation–
    StorageInformationpage.
    ThefollowinginformationislistedforthelogicaldrivesattachedtoanHPSmartArraycontroller:
    •Logicaldrivenumber
    •Logicaldrivestatus
    ViewingiLOsysteminformation169 
    						
    							•Logicaldrivecapacity
    •Faulttolerance
    •LogicalDriveType
    •Encryptionstatus
    NOTE:LogicaldrivesmustbeconfiguredthroughtheHPSmartStorageAdministratorsoftware
    beforetheycanbedisplayedontheSystemInformation–StorageInformationpage.Formore
    information,seetheHPSmartStorageAdministratordocumentation.
    PhysicalDrives
    TheinformationlistedinthissectiondependsonwhethertheLogicalVieworPhysicalViewoption
    isselected.WhenusingLogicalView,physicaldrivesthatareconfiguredaspartofanarrayare
    listed.WhenusingPhysicalView,allphysicaldrivesarelisted.
    WhenaphysicaldrivehasaFailedstatus,thisstatusdoesnotaffecttheoverallstoragehealth
    status.Onlylogicaldrivesaffectthestoragehealthstatus.
    ThefollowinginformationislistedforthephysicaldrivesattachedtoanHPSmartArraycontroller:
    •Physicaldriveport,box,andbaynumbers
    •Physicaldrivestatus
    •Physicaldriveserialnumber
    •Physicaldrivemodelnumber
    •Physicaldrivecapacity
    •Physicaldrivelocation
    •Physicaldrivefirmwareversion
    •Physicaldriveconfiguration
    •Encryptionstatus
    Viewingfirmwareinformation
    TheFirmwareInformationpagedisplaysfirmwareinformationforvariousservercomponents.
    Iftheserverispoweredoff,theinformationonthispageiscurrentasofthelastpoweroff.Firmware
    informationisupdatedonlywhentheserverispoweredonandPOSTiscomplete.
    Toviewfirmwareinformation,navigatetotheInformation→SystemInformationpage,andthen
    clicktheFirmwaretab.
    170UsingiLO 
    						
    All HP manuals Comments (0)

    Related Manuals for HP Ilo 4 User Guide