    SM 5-135 B230/B237 
    Service 
    Tables 
    (77 mm/s): 2nd Side 
    003 Paper Transfer: FINE: 1st 
    Side *ENG
    004 Paper Transfer: FINE: 
    2nd Side *ENGNot used 
    005-008 Adjusts the environment coefficient for each mode. When the environment is 
    detected as HH, SP2851 is multiplied by these SP values. 
    005 Separation DC: Thick 1 
    (77 mm/s): 1st Side *ENG
    006 Separation DC: Thick 1 
    (77 mm/s): 2nd Side: *ENG[10 to 250 / 80 / 5%/step] 
    007 Separation DC: FINE: 1st 
    Side *ENG
    008 Separation DC: FINE: 
    2nd Side *ENGNot used 
     
    [OPC Drum Brake Time]  
    2901 
    Adjusts the time when the OPC drum motor reverses from normal rotation after 
    job end. DFU 
    001 Plain  *ENG
    002 Thick 1  *ENG
    003  Thick 2 & FINE  *ENG[100 to 1500 / 500 / 10 msec/step] 
     
    [OPC Drum Reverse Time]  
    2902 
    Adjusts the time for how long the OPC drum motor reverses after job end. DFU
    001 All: BW  *ENG
    002 All: FC  *ENG[0 to 200 / 40 / 10 msec/step]  
    						
    							 
    B230/B237 5-136  SM 
     
    [Image Transfer Roller Brake Time]  
    2903 
    Adjusts the time when the image transfer belt motor reverses from normal 
    rotation after job end. DFU 
    003 Plain  *ENG
    004 Thick 1  *ENG
    005  Thick 2 & FINE  *ENG[100 to 1500 / 500 / 10 msec/step] 
     
    [OPC Drum Reverse Time]  
    2904 
    Adjusts the time for how long the image transfer belt motor reverses after job 
    end. DFU 
    003 All  *ENG
    [0 to 200 / 30 / 10 msec/step] 
     
    [ACS Setting (FC to Bk)]  
    2907 Adjusts the threshold for moving away the image transfer belt from the color 
    PCUs. This SP moves the image transfer belt away from the color PCUs when 
    the number of B/W image printouts reaches the number of sheets specified 
    with this SP after consecutive full color image printouts in the full color mode. 
    If this SP is set to 0, the image transfer belt does not move away. 
    001  Continuous Bk Pages  *ENG
    [0 to 10 / 0 / 1 sheet/step] 
     
    [GainAdjust] Gain Adjustment of Image Transfer Belt Motor 
    2908 
    DFU 
    001 154 mm/sec  *ENG
    002 138 mm/sec  *ENG
    003 115 mm/sec  *ENG
    004 77 mm/sec  *ENG[0 or 1 / 1 / 1/step]] 
    0: High speed (Low level) 
    1: Low speed (High level)  
    						
    							 
    SM 5-137 B230/B237 
    Service 
    Tables 
     
    [Motor Start Control] 
    2909 
    Not used 
    001 On  *ENG[0 to 1 / 0 / 1 sheet/step] 
    0: normal, 1: synchro 
     
    [Motor Stop Control] 
    2910 
    Not used 
    001 On  *ENG[0 to 1 / 0 / 1 sheet/step] 
    0: normal, 1: synchro 
     
    [Drum Stop Timing] OPC Drum Motor Stop Timing Adjustment 
    2911 
    Not used 
    001 Bk  *ENG
    002 MCY  *ENG[0 to 360 / 30 / 6 deg/step] 
     
    [Gear Phase Control Result] 
    2912 
    DFU 
    001 Bk - M  *ENG
    [–180 to 180 / 0 / 1 deg/step] 
     
    [Gear Phase Control] 
    2913 
    Enables or disables the OPC gear phase adjustment after job end. 
    001 Job End  *ENG[0 or 1 / 1 / 1/step] 
    0: OFF, 1: ON 
     
    2914 [Dust Shield Shutter Motor]   
    						
    							 
    B230/B237 5-138  SM 
    001  Stop Delay: Open  *ENG
    002  Stop Delay: Close  *ENGDFU 
    [1 to 50 / 38 / 1 ms/step] 
    003 Open Execution  *ENGOpens the shutter on the laser optics 
    housing unit manually for test purposes. 
    004 Close Execution  *ENGCloses the shutter on the laser optics 
    housing unit manually for test purposes. 
    007 Presence  *ENG Not used 
     
    [GainAdjust] Gain Adjustment of OPC Bk Drum Motor 
    2915 
    DFU 
    001 154 mm/sec  *ENG
    002 138 mm/sec  *ENG
    003 115 mm/sec  *ENG
    004 77 mm/sec  *ENG[0 or 1 / 0 / 1/step] 
    0: TGAIN: High, 1: GAIN: Low 
     
    [GainAdjust] Gain Adjustment of OPC MCY Drum Motor 
    2916 
    DFU 
    001 154 mm/sec  *ENG
    002 138 mm/sec  *ENG
    003 115 mm/sec  *ENG
    004 77 mm/sec  *ENG[0 or 1 / 0 / 1/step] 
    0: TGAIN: High, 1: GAIN: Low 
     
    [SecondaryFB: Threshold] Paper Transfer Roller Feed-back: Threshold 
    Adjustment 
    2930 
    Adjusts the threshold between high resistance (division 1) and low resistance 
    (division 2) at the paper transfer roller. This SP affects SP2931 to SP2939.  
    						
    							 
    SM 5-139 B230/B237 
    Service 
    Tables 
    001 Voltage  *ENG
    [0 to 7000 / 5000 / 10 –V/step] 
     
    [SecondaryFB: Plain]  
    2931 
    Adjusts the upper limit voltage for the paper transfer roller. These SPs are only 
    used for plain paper use in full color mode. 
    001  Limit Voltage: Division 1  *ENG
    [0 to 7000 / 6000 / 10 –V/step] 
    002  Limit Voltage: Division 2  *ENG
    [0 to 7000 / 5000 / 10 –V/step] 
     
    [SecondaryFB: Thin]  
    2932 
    Adjusts the upper limit voltage for the paper transfer roller. These SPs are only 
    used for thin paper use in full color mode. 
    001  Limit Voltage: Division 1  *ENG
    [0 to 7000 / 6000 / 10 –V/step] 
    002  Limit Voltage: Division 2  *ENG
    [0 to 7000 / 5000 / 10 –V/step] 
     
    [SecondaryFB: Special 1]  
    2933 
    Adjusts the upper limit voltage for the paper transfer roller. These SPs are only 
    used for special 1 paper use in full color mode. 
    001  Limit Voltage: Division 1  *ENG
    [0 to 7000 / 6000 / 10 –V/step] 
    002  Limit Voltage: Division 2  *ENG
    [0 to 7000 / 5000 / 10 –V/step] 
     
    [SecondaryFB: Special 2]  
    2934 
    Adjusts the upper limit voltage for the paper transfer roller. These SPs are only 
    used for special 2 paper use in full color mode. 
    001  Limit Voltage: Division 1  *ENG
    [0 to 7000 / 6000 / 10 –V/step] 
    002  Limit Voltage: Division 2  *ENG
    [0 to 7000 / 5000 / 10 –V/step] 
      
    						
    							 
    B230/B237 5-140  SM 
    [SecondaryFB: Thick 1]  
    2935 
    Adjusts the upper limit voltage for the paper transfer roller. These SPs are only 
    used for thick 1 paper use in full color mode. 
    001  Limit Voltage: Division 1  *ENG
    [0 to 7000 / 6000 / 10 –V/step] 
    002  Limit Voltage: Division 2  *ENG
    [0 to 7000 / 5000 / 10 –V/step] 
     
    [SecondaryFB: Thick 2]  
    2936 
    Adjusts the upper limit voltage for the paper transfer roller. These SPs are only 
    used for thick 2 paper use in full color mode. 
    001  Limit Voltage: Division 1  *ENG
    [0 to 7000 / 6000 / 10 –V/step] 
    002  Limit Voltage: Division 2  *ENG
    [0 to 7000 / 5000 / 10 –V/step] 
     
    [SecondaryFB: Thick 3]  
    2937 
    Adjusts the upper limit voltage for the paper transfer roller. These SPs are only 
    used for thick 3 paper use in full color mode. 
    001  Limit Voltage: Division 1  *ENG
    [0 to 7000 / 6000 / 10 –V/step] 
    002  Limit Voltage: Division 2  *ENG
    [0 to 7000 / 5000 / 10 –V/step] 
     
    [SecondaryFB: OHP]  
    2938 
    Adjusts the upper limit voltage for the paper transfer roller. These SPs are only 
    used for OHP paper use in full color mode. 
    001  Limit Voltage: Division 1  *ENG
    [0 to 7000 / 6000 / 10 –V/step] 
    002  Limit Voltage: Division 2  *ENG
    [0 to 7000 / 5000 / 10 –V/step] 
     
    [SecondaryFB: Special 3]  
    2939 
    Adjusts the upper limit voltage for the paper transfer roller. These SPs are only  
    						
    							 
    SM 5-141 B230/B237 
    Service 
    Tables 
    used for special 3 paper use in full color mode. 
    001  Limit Voltage: Division 1  *ENG
    [0 to 7000 / 6000 / 10 –V/step] 
    002  Limit Voltage: Division 2  *ENG
    [0 to 7000 / 5000 / 10 –V/step] 
     
    SP3-XXX (Process) 
    3011 [Process Cont. Manual Execution]  
    001 Normal   Executes the normal process control 
    manually (potential control). 
    Check the result with SP3-325-001 and 
    3-012-001 after executing this SP. 
    002 Density Adjustment   Executes the toner density adjustment 
    manually. 
    003 Pre-ACC   Executes the process control that is 
    normally done before ACC.   
    The type of process control is selected with 
    SP3-041-004. 
    004 Full MUSIC   Executes the process control that is 
    normally done at the same time as MUSIC. 
    This SP does the MUSIC (line position 
    adjustment) twice. 
    005 Normal MUSIC   Executes the process control that is 
    normally done at the same time as MUSIC. 
    This SP does the MUSIC (line position 
    adjustment) once. 
     
    [Process Cont. Check Result] Process Control Self-check Result 
    3012 Displays the result of the latest process control self-check. 
    All colors are displayed. The results are displayed in the order “Y C M K”   
    e.g., 11 (Y) 99 (C) 11 (M) 11 (K): The self-check for Cyan failed but the others 
    were successful.  
    						
    							 
    B230/B237 5-142  SM 
    See the troubleshooting section for details. 
    001 History: Latest  *ENG
    002  Result: Latest 1  *ENG
    003  Result: Latest 2  *ENG
    004  Result: Latest 3  *ENG
    005  Result: Latest 4  *ENG
    006  Result: Latest 5  *ENG
    007  Result: Latest 6  *ENG
    008  Result: Latest 7  *ENG
    009  Result: Latest 8  *ENG
    010  Result: Latest 9  *ENG[ 11111111  t o  99999999 / - / 1/step] 
     
    3013 [T Sensor Initial Set: Execution] Developer Initialization Setting 
    001 Execution: ALL  - 
    002  Execution: COL (MCY)  - 
    003 Execution: Bk  - 
    004 Execution: M  - 
    005 Execution: C  - 
    006 Execution: Y  - DFU  
     
    3014 [T Sensor Initial Set Result: Display] Developer Initialization Result: Display 
    Display: YCMK  *ENG[0 to 9999 / - / - ] 
    1: Success 
    2 to 9: Failure 
    001 
    Displays the developer initialization result. See section 4.1.1 for details on the  
    						
    							 
    SM 5-143 B230/B237 
    Service 
    Tables 
    meaning of each code. 
    All colors are displayed. Values are displayed in the order Y C M Bk. 
    e.g., 1 (Y) 2 (C) 1 (M) 1 (Bk): Initialization of Cyan failed but the others 
    succeeded. 
     
    3015 [Forced Toner Supply] Forced Toner Supply ([Color]) 
    001 Execution: ALL  - 
    002  Execution: COL (MCY)  - 
    003 Execution: Bk  - 
    004 Execution: M  - 
    005 Execution: C  - 
    006 Execution: Y  - Executes the manual toner supply to the 
    development unit. 
     
    [Forced Toner Supply: Setting] Forced Toner Supply Setting ([Color]) 
    3016 
    Specifies the manual toner supply time for each color. 
    001 Supply Time: Bk  *ENG
    002 Supply Time: M  *ENG
    003 Supply Time: C  *ENG
    004  Supply Time: Y  *ENG[0 to 30 / 4 / 1 sec/step] 
     
    [Vt Limit Error]  
    3020 
    DFU 
    001 Delta Vt Threshold  *ENG
    [0 to 5 / 5 / 0.01 V/step] 
    002 Upper Threshold  *ENG
    [0 to 5 / 4.7 / 0.01 V/step] 
    003 Threshold Number of 
    Upper counter *ENG
    [0 to 99 / 20 / 1 time/step]  
    						
    							 
    B230/B237 5-144  SM 
    004 Lower Threshold  *ENG
    [0 to 5 / 0.5 / 0.01 V/step] 
    005  Number of Lower counter *ENG
    [0 to 99 / 10 / 1 time/step] 
    006  Upper Counter: Bk  *ENG
    007  Upper Counter: M  *ENG
    008  Upper Counter: C  *ENG
    009 Upper Counter: Y  *ENG
    010  Lower Counter: Bk  *ENG
    011  Lower Counter: M  *ENG
    012  Lower Counter: C  *ENG
    013 Lower Counter: Y  *ENG[0 to 99 / 0/ 1 time/step] 
     
    [TD Sensor Initial Set] Developer Initialization Setting 
    3021 
    Specifies the developer agitation time for each color at the developer 
    initialization. DFU 
    001 Agitation Time: Bk  *ENG
    002 Agitation Time: M  *ENG
    003 Agitation Time: C  *ENG
    004 Agitation Time: Y  *ENG[0 to 200 / 30 / 1 sec/step] 
    005-008 
    Sets the execution flag of the developer initialization for each color. DFU 
    005  Execution Flag: Bk  *ENG
    006  Execution Flag: M  *ENG
    007  Execution Flag: C  *ENG
    008 Execution Flag: Y  *ENG[0 or 1 / 0 / 1/step] 
    0: Flag OFF, 1: Flag ON 
    This flag is cleared after executing TD 
    sensor initialization. 
    009  Prohibition  *ENG Enables or disables developer initialization.  
    						