    [ID Sensor Detection Value: Vsgave]  
    3313 
    Not used 
    001  Vsgave reg: Bk  *ENG
    002  Vsgave reg: M  *ENG
    003  Vsgave reg: C  *ENG
    004 Vsgave reg: Y  *ENG[0 to 5.5 / - / 0.01 V/step] 
    005-007 Not used 
    005 Vsgave dif: M  *ENG
    006 Vsgave dif: C  *ENG
    007 Vsgave dif: Y  *ENG[0 to 5.5 / - / 0.01 V/step] 
    008-010 Not used 
    008 Vsgave TM (Front)  *ENG
    009 Vsgave TM (Center)  *ENG
    010 Vsgave TM (Rear)  *ENG[0 to 5.5 / - / 0.01 V/step] 
     
    3321 [Vsg Adjustment: Execution]  
    010 P/TM Sensor All  - Execute the ID sensor initialization setting 
    for all sensors 
     
    [Vsg Adjustment Result: Vsg]  
    3322 
    Displays the result value of the Vsg adjustment for each sensor. 
    001  Vsg reg: Bk  *ENG
    002  Vsg reg: M  *ENG
    003  Vsg reg: C  *ENG[0 to 5.5 / - / 0.01 V/step]  
    						
    							 
    B230/B237 5-166  SM 
    004 Vsg reg: Y  *ENG
    005  Vsg dif: M  *ENG
    006  Vsg dif: C  *ENG
    007 Vsg dif: Y  *ENG[0 to 5.5 / - / 0.01 V/step] 
    008 Vsg TM (Front)  *ENG
    009 Vsg TM (Center)  *ENG
    010 Vsg TM (Rear)  *ENG[0 to 5.5 / - / 0.01 V/step] 
     
    3323 [Vsg Adjustment Result: Ifsg] DFU 
    001 Ifsg: Bk  *ENG
    002 Ifsg: M  *ENG
    003 Ifsg: C  *ENG
    004 Ifsg: Y  *ENG[0 to 50 / - / 0.1 mA/step] 
    005 Ifsg TM (Front)  *ENG
    006 Ifsg TM (Center)  *ENG
    007 Ifsg TM (Rear)  *ENG[0 to 50 / - / 0.1 mA/step] 
     
    3324 [Vsg Adjustment: Set] DFU 
    002  Vofset Error Counter  *ENG
    003  Vofset Error Counter  *ENG[0 to 99 / - / 0.1 time/step] 
    004 Vofset Threshold  *ENG
    [0 to 5 / 1 / 0.01 V/step] 
    005 Vsg Upper Threshold  *ENG
    [0 to 5 / 4.5 / 0.01 V/step] 
    006 Vsg Lower Threshold  *ENG
    [0 to 5 / 3.5 / 0.01 V/step] 
      
    						
    							 
    SM 5-167 B230/B237 
    Service 
    Tables 
    [Vsg Adjustment Result]  
    3325 Displays the result of the Vsg adjustment. 
    The displayed numbers mean the result of each sensor (sensor for Front, 
    sensor for Bk, sensor for Cyan, sensor for Center, sensor for Magenta, sensor 
    for Yellow and sensor for Rear). 
    001 Latest  *ENG
    002 Latest 1  *ENG
    003 Latest 2  *ENG
    004 Latest 3  *ENG
    005 Latest 4  *ENG
    006 Latest 5  *ENG
    007 Latest 6  *ENG
    008 Latest 7  *ENG
    009 Latest 8  *ENG
    010 Latest 9  *ENG[ 1111111  t o  9999999 / 9999999 / 1 /step] 
    9: Unexpected error 
    3: Offset voltage error 
    2: Vsg adjustment value error 
    1: O.K 
     
    3361 [ID Sensor Sensitivity: Display] Not Used 
    001 K2K (Latest)  *ENG
    002 K5K (Latest)  *ENG
    003 K2M (Latest)  *ENG
    004 K5M (Latest)  *ENG
    005 K2C (Latest)  *ENG
    006 K5C (Latest)  *ENG
    007 K2Y (Latest)  *ENG
    008 K5Y (Latest)  *ENG[0 to 5 / - / 0.0001 /step]  
    						
    							 
    B230/B237 5-168  SM 
     
    3362 [ID Sensor Sensitivity: Setting] DFU 
    001 K2: Upper  *ENG
    [0 to 1 / 0.32 / 0.01 /step] 
    002 K2: Lower  *ENG
    [0 to 1 / 0.22 / 0.01 /step] 
    003 K5: Upper  *ENG
    [0 to 10 / 5 / 0.01 /step] 
    004 K5: Lower  *ENG
    [0 to 10 / 0.5 / 0.01 /step] 
    005 Kn: Lower  *ENG
    [0 to 1 / 0.1 / 0.01 /step] 
    006 Kn: Upper  *ENG
    [0 to 1 / 1 / 0.01 /step] 
    007  K5 Edit Point  *ENG
    [0 to 1 / 0.15 / 0.01 /step] 
    008 K5 Target Voltage  *ENG
    [0 to 5 / 1.63 / 0.01 V/step] 
    009 K5 Approximate Method  *ENG[0 to 1 / 1 / 1 /step] 
    0:Linear, 1: Curve 
    010 K2: Upper/Lower Limit 
    Coefficient 1 *ENG
    [0 to 1 / 0 / 0.01 /step] 
    011 K2: Upper Limit 
    Correction *ENG
    [–0.2 to 0.4 / 0.07 / 0.01 /step] 
    012 K2: Lower Limit 
    Correction *ENG
    [–0.2 to 0.4 / –0.07 / 0.01 /step] 
    013  Diffusion Correction: M  *ENG
    014  Diffusion Correction: C  *ENG
    015 Diffusion Correction: Y  *ENG[0.75 to 1.35 / 1 / 0.01 /step] 
    016 K2: Check: M  *ENG
    017 K2: Check: C  *ENG
    018 K2: Check: Y  *ENG[0 to 1 / 0.25 / 0.001 /step] 
      
    						
    							 
    SM 5-169 B230/B237 
    Service 
    Tables 
    3363 [ID Pattern Timing Setting] DFU 
    001 Scan YCMBk  *ENGAdjusts the detection timing for the process 
    control pattern. 
    [-500 to 500 / 13.7 / 1 mm/step] 
    002 Paper Transfer Release 
    Start  Ti m e *ENGAdjusts the timing when the paper transfer 
    unit is kept away from the image transfer 
    belt. 
    [0 to 2500 / 0 / 1 msec/step] 
    003 Delay Time  *ENGAdjusts the processing timing for the 
    process control pattern. 
    [0 to 2500 / 600 / 1 msec/step] 
    004 MUSIC Delay Time  *ENGAdjusts the processing timing for the 
    pattern that is used for the line position 
    adjustment. 
    [-2500 to 2500 / 300 / 1 msec/step] 
     
    3371 [M/A Calculation] DFU 
    001  Correction Coefficient: Bk *ENG
    [0.5 to 2.0 / 1.04 / 0.01 /step] 
    002  Correction Coefficient: M  *ENG
    [0.5 to 2.0 / 0.98 / 0.01 /step] 
    003  Correction Coefficient: C  *ENG
    [0.5 to 2.0 / 1.11 / 0.01 /step] 
    004 Correction Coefficient: Y  *ENG
    [0.5 to 2.0 / 0.91 / 0.01 /step] 
     
    [Fixed Supply Mode] 
    3401 
    Adjusts the toner supply rate in the fixed toner supply mode. 
    001  Fixed Rate: Bk  *ENG
    002  Fixed Rate: M  *ENG
    003  Fixed Rate: C  *ENG[0 to 100 / 5 / 1 %/step] 
    These SPs are used only when SP3-044 is 
    set to 1.  
    						
    							 
    B230/B237 5-170  SM 
    004 Fixed Rate: Y  *ENG
     
    [Toner Supply Rate: Display] 
    3411 
    Displays the current toner supply rate. 
    001 Latest: Bk  *ENG
    002 Latest: M  *ENG
    003 Latest: C  *ENG
    004 Latest: Y  *ENG[0 to 100 / - / 1 %/step] 
     
    3421 [Toner Supply Range] 
    001 Upper Limit: Bk  *ENG
    002 Upper Limit: M  *ENG
    003 Upper Limit: C  *ENG
    004 Upper Limit: Y  *ENGAdjusts the toner supply rate during 
    printing. 
    [0 to 100 / 100 / 1%/step] 
    005 Minimum Supply Time: 
    Bk *ENG
    006  Minimum Supply Time: M  *ENG
    007  Minimum Supply Time: C  *ENG
    008  Minimum Supply Time: Y  *ENGAdjusts the minimum toner supply time. 
    [0 to 1000 / 0 / 1 msec/step] 
     
    3451 [Toner Supply Carry Over: Display] DFU 
    001 Bk  *ENG
    002 M  *ENG
    003 C  *ENG
    004 Y  *ENG[0 to 10000 / 0 / 1 msec/step]  
    						
    							 
    SM 5-171 B230/B237 
    Service 
    Tables 
     
    3452 [Toner Supply Carry Over: Setting] DFU 
    001 Maximum: Bk  *ENG
    002 Maximum: M  *ENG
    003 Maximum: C  *ENG
    004 Maximum: Y  *ENG[0 to 10000 / 1000 / 1 msec/step] 
     
    [Process Control Target M/A] 
    3501 
    Adjusts the target M/A. 
    001  Maximum M/A: Bk  *ENG
    002  Maximum M/A: M  *ENG
    003  Maximum M/A: C  *ENG[0 to 1 / 0.42 / 0.001 mg/cm
    2/step] 
    004 Maximum M/A: Y  *ENG
    [0 to 1 / 0.43 / 0.001 mg/cm2/step] 
     
    [Image Quality Adj. Counter: Display] 
    3510 
    Displays the total page counter for each adjustment mode. 
    001  Potential Control: BW  *ENG
    002  Potential Control: FC  *ENG
    003  Power ON: BW  *ENG
    004  Power ON: FC  *ENG
    005 MUSIC: BW  *ENG
    006 MUSIC: FC  *ENG
    007 Vsg Adj.  *ENG
    008 Charge AC Control  *ENG[0 to 2000 / 0 / 1 page/step] 
      
    						
    							 
    B230/B237 5-172  SM 
    [Execution Interval: Setting] 
    3511 
    Adjusts the threshold for each adjustment mode. 
    001 Job End: Potential 
    Control: BW *ENG
    [0 to 2000 / 250 / 1 page/step] 
    002 Job End: Potential 
    Control: FC *ENG
    [0 to 2000 / 100 / 1 page/step] 
    003 Interrupt: Potential 
    Control: BW *ENG
    [0 to 2000 / 500 / 1 page/step] 
    004 Interrupt: Potential 
    Control: FC *ENG
    [0 to 2000 / 200 / 1 page/step] 
    005 Initial: Potential Control: 
    BW *ENG
    [0 to 2000 / 200 / 1 page/step] 
    006 Initial: Potential Control: 
    FC *ENG
    [0 to 2000 / 100 / 1 page/step] 
    007 Vsg Adj. Counter  *ENG
    [0 to 2000 / 500 / 1 page/step] 
    008 Charge AC  Control 
    Counter *ENG
    [0 to 2000 / 500 / 1 page/step] 
    019 Environmental Correction *ENG[0 or 1 / 1 / 1 /step] 
    0: Not Correct (OFF), 1: Correct (ON) 
    020 Gamma Correction  *ENG[0 or 1 / 1 / 1 /step] 
    0: Not Correct (OFF), 1: Correct (ON) 
    021 Non-use Time Correction  *ENG[0 or 1 / 1 / 1 /step] 
    0: Not Correct (OFF), 1: Correct (ON) 
    022 Correction Coefficient 1: 
    JE: BW *ENG
    [0 to 1 / 0.2 / 0.01 page/step] 
    023 Correction Coefficient 2: 
    JE: BW *ENG
    [0 to 1 / 1 / 0.01/step] 
    024  Correction Coefficient 1:  *ENG
    [0 to 1 / 0.5 / 0.01/step]  
    						
    							 
    SM 5-173 B230/B237 
    Service 
    Tables 
    JE: FC 
    025 Correction Coefficient 2: 
    JE: FC *ENG
    [0 to 1 / 1 / 0.01/step] 
    026 Correction Coefficient 1: 
    Interrupt: BW *ENG
    [0 to 1 / 0.1 / 0.01/step] 
    027 Correction Coefficient 2: 
    Interrupt: BW *ENG
    [0 to 1 / 1 / 0.01/step] 
    028 Correction Coefficient 1: 
    Interrupt: FC *ENG
    [0 to 1 / 0.25 / 0.01/step] 
    029 Correction Coefficient 2: 
    Interrupt: FC *ENG
    [0 to 1 / 1 / 0.01/step] 
    030 Max. Number Correction 
    Threshold *ENG
    [0 to 99 / 2 / 1/step] 
    031 Max. Number Correction 
    Counter *ENG
    [0 to 255 / 0 / 1/step] 
     
    [Image Quality Adj.: Interval] 
    3512 
    Adjusts the timing for execution of process control and line position adjustment.
    001 During Job  *ENG
    [0 to 100 / 30 / 1 page/step] 
    002 During Stand-by  *ENG
    [0 to 100 / 10 / 1 minute/step] 
     
    [PCU Motor Stop Time: Bk] 
    3513 
    Displays the last time that the PCU motors stopped. 
    These are used for process control execution timing. 
    001 Year  *ENG
    [0 to 99 / 0 / 1/step] 
    002 Month  *ENG
    [1 to 12 / 1 / 1/step] 
    003 Date  *ENG
    [1 to 31 / 1 / 1/step]  
    						
    							 
    B230/B237 5-174  SM 
    004 Hour  *ENG
    [0 to 23 / 0 / 1/step] 
    005 Minute  *ENG
    [0 to 59 / 0 / 1/step] 
     
    [Environmental Display: Job End] 
    3514 
    Displays the environmental conditions for the last job. 
    These are used for process control execution timing. 
    001 Temperature  *ENG
    [-1280 to 1270 / 0 / 0.1°C/step] 
    002 Relative Humidity  *ENG
    [0 to 1000 / - / 0.1%RH/step] 
    003 Absolute Humidity  *ENG
    [0 to 1000 / - / 0.1 g/cm3/step] 
     
    [Execution Interval: Display] 
    3515 Displays the current interval for process control execution.   
    When the machine calculates the timing for process control, it uses a number 
    of conditions. These are the results after considering all the conditions. 
    001 Job End: Potential 
    Control: BW *ENG [0 to 2000 / – / 1 page/step] 
    002 Job End: Potential 
    Control: FC *ENG [0 to 2000 / – / 1 page/step] 
    003 Interrupt: Potential 
    Control: BW *ENG [0 to 2000 / – / 1 page/step] 
    004 Interrupt: Potential 
    Control: FC *ENG [0 to 2000 / – / 1 page/step] 
     
    [Refresh Mode] DFU 
    3516 While making prints with low coverage, the developer is agitated with less toner 
    consumption and the toner carrier attraction tends to increase. This may cause 
    low image density or poor transfer (white dots). To prevent this, the coagulated 
    toner or overcharged toner has to be consumed by performing the refresh  
    						
    All Ricoh manuals Comments (0)