Home > GE > Ultrasound System > GE Logiq P5 User Manual

GE Logiq P5 User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual GE Logiq P5 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 45 GE manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 878
    							Console Overview
    LOGIQ 5 Basic User Manual 3-11
    Direction 2300002-100 Rev. 2
    Peripheral/Accessory Connector Panel (continued)
     Figure 3-5. Peirpheral/Accessory Connector Panel
    220-240V  500VA MaxIncluding front printer panel220-240V  500VA MaxIncluding rear panel
    100~120V  500VA MaxIncluding front printer panel100~120V  500VA MaxIncluding rear panel
    Japan/USA/Asia Console (100~120V
    Europe/USA Console (220V)
    CAUTIONThe connection of equipment or transmission networks other 
    than as specified in these instructions can result in electric 
    shock hazard. Alternate connections will require verification of 
    compatibility and conformity to IEC/EN 60601-1-1 by the 
    installer. 
    						
    							Preparing the System for Use
    3-12 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Peripheral/Accessory Connector Panel (continued)
    Table 3-2: Peripheral/Accessory Connector Panel Descriptions
    No.ItemType of connector Required Cable
    1. S-Video Out S-Terminal, 4-pin
    2. Composite Color/
    BW
    3. Audio In/Out RCA
    4. S-Video In
    5. Camera Color/
    Camera B/W
    6. VGA Shrinked D-Sub, 15-pin
    7. Service USB(A)
    8. VCR 1 USB(A)
    9. VCR 2 USB(A)
    10. For Future use
    11 .  Insite RJ-11 Modular, 6-pin
    12. Ethernet RJ-45 Modular, 8-pin
    13. Power IEC Couplers
    243
    1
     1
     6
     115 
    10 
    15 
    1  2  3  4
    6 1
     8 1 
    						
    							Console Overview
    LOGIQ 5 Basic User Manual 3-13
    Direction 2300002-100 Rev. 2
    Footswitch (Option)
    Use only the recommended optional multifunctional footswitch.
     Figure 3-6. Footswitch
    The footswitch may be used as select keys, video recording, etc. 
    The three switches have different function assignments 
    depending on the current application.
    The footswitch connection is located below the operator control 
    panel.
    CAUTIONDO NOT place or store the footswitch in the side pocket or the 
    Peripheral Device storage area on the system. This is to 
    prevent the possibility of the footswitch falling and damaging 
    itself. 
    						
    							Preparing the System for Use
    3-14 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    System Positioning/Transporting
    Moving the System
    When moving or transporting the system, follow the precautions 
    below to ensure the maximum safety for personnel, the system, 
    and other equipment. 
    Before moving the system
    1.  Press the Power on/Standby switch and turn off the circuit 
    breaker to power off. See ‘Power Off’ for more information.
    2.  Unplug the power cord.
    3.  All cables from off-board peripheral devices (IIE camera, 
    external printer, VCR, etc.) must be disconnected from the 
    console.
    4.  Disconnect the footswitch from the console.
    5.  Ensure that no loose items are left on the console.
    6.  Wind the power cable around the cable hook below the rear 
    handle or wrap the cord in a bundle and store it behind the 
    rear storage panel. 
    CAUTIONPlease ensure that the peripheral devices, which are 
    installed in the storage areas, are secured with the 
    supplied straps.  
    						
    							System Positioning/Transporting
    LOGIQ 5 Basic User Manual 3-15
    Direction 2300002-100 Rev. 2
    Before moving the system (continued)
    To prevent damage to the Power Cord, DO NOT pull 
    excessively on the cord or make sharp bends while 
    wrapping.
     Figure 3-7. Location of rear handle
    a. Handle
    7.  Connect all probes to be used while off site. Ensure that 
    probe cables are out of the way from the wheels and not 
    protruding beyond the console.
    NOTE:  If more than three (3) probes are intended to be used, store 
    the additional probes securely.
    8.  Store all other probes in their original cases or in soft cloth 
    or foam to prevent damage.
    9.  Store sufficient gel and other essential accessories in the 
    provided space.
    10.  Adjust the monitor and control panel to its lowest position 
    possible by using the release lever located underneath the 
    control panel.
    11. Unlock the wheels.
    a
    CAUTIONDO NOT place probes or the footswitch into either the side 
    pocket or the peripheral device’s storage area when 
    moving the system. These are not storage spaces for 
    probes or the footswitch. 
    						
    							Preparing the System for Use
    3-16 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    When moving the system
    1.  Always use the rear handle grips to move the system.
    2.  Take extra care when moving the system long distances and 
    on inclines. Ask for help if necessary.
    Avoid ramps that are steeper than ten degrees to avoid 
    tipping over the
     system. 
    NOTE:  Wheel chair ramps are usually less than five degrees. 
    Utilize additional care and personnel when moving on steep 
    incline (>5°) or loading into a vehicle for transport. 
    3.  Use the foot brake (pedal), located on the bottom of the 
    system in the front, when necessary.
    4.  Do not let the system strike walls or door frames.
    5.  Use extra care when crossing door or elevator thresholds.
    6.  Once the destination is reached, lock the wheels. 
    CAUTIONDO NOT attempt to move the console using any cables or 
    fixtures, such as the probe connectors.
    CAUTIONThe system weighs approximately 180 kg (397 lbs). To avoid 
    possible injury and equipment damage:
    •  Be sure the pathway is clear.
    •  Limit movement to a slow careful walk.
    •  Use two or more persons to move the system on inclines or 
    long distances. 
    						
    							System Positioning/Transporting
    LOGIQ 5 Basic User Manual 3-17
    Direction 2300002-100 Rev. 2
    Transporting the System
    Use extra care when transporting the system using vehicles. In 
    addition to the instructions used when moving the system (See 
    ‘Moving the System’ for more information.), also perform the 
    following:
    1.  Only use vehicles that are designed for transport of the 
    LOGIQ 5 system.
    2.  Load and unload the system to a vehicle parked on a level 
    surface.
    3.  Ensure that the transporting vehicle can handle the weight 
    of the system plus the passengers.
    4.  Ensure that the load capacity of the lift (a minimum of 180 kg 
    [397 lbs] is recommended) is capable of handling the weight 
    of the system. 
    5.  Ensure that the lift is in good working order.
    6.   Secure the system while it is on the lift so that it cannot roll. 
    Use either wood chocks, restraining straps, or other similar 
    types of constraints. Do not attempt to hold it in place by 
    hand. 
    NOTE:  Strap the system below its handle so that the system does 
    not break loose.
    7.  Employ two to three persons to load and unload safely from 
    a vehicle. 
    WARNINGNever ride on the lift with the system. A persons weight 
    coupled with the weight of the system may exceed the load 
    capacity of the lift. 
    						
    							Preparing the System for Use
    3-18 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Transporting the System (continued)
    8.  Load the unit aboard the vehicle carefully and over its center 
    of gravity. Keep the unit still and upright. 
    NOTE:  Do not lay the unit down. 
    9.  Ensure that the system is firmly secured while inside the 
    vehicle. Any movement, coupled with the weight of the 
    system, could cause it to break loose. 
    10.  Secure system with straps or as directed otherwise to 
    prevent motion during transport. 
    11.  Prevent vibration damage by driving cautiously. Avoid 
    unpaved roads, excessive speeds, and erratic stops or 
    starts. 
    						
    							System Positioning/Transporting
    LOGIQ 5 Basic User Manual 3-19
    Direction 2300002-100 Rev. 2
    Wheels
    Examine the wheels frequently for any obvious defects that 
    could cause them to break or bind. 
    Front wheels
    Swivel and brake lock.
    Back wheels
    Swivel, swivel lock and brake lock.
    Setting the lock
    The pedal is located in the front wheels of the unit and  enables 
    the user to control the movement of the wheels.
     Figure 3-8. Front Pedal
    1. Unlock
    2. Lock
    1
    2 
    						
    							Preparing the System for Use
    3-20 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Powering the System
    Connecting and Using the System
    To connect the system to the electrical supply:
    1.  Ensure that the wall outlet is of the appropriate type.
    2.  Ensure that the power switch is turned off.
    3.  Unwrap the power cable. Make sure to allow sufficient slack 
    in the cable so that the plug is not pulled out of the wall if the 
    system is moved slightly.
    4.  Attach the power plug to the system and secure it in place 
    by using the retaining clamp.
     Figure 3-9. Power Plug
    a.  Retaining clamp for power plug
    5.  Push the power plug securely into the wall outlet.
    a
    CAUTIONEnsure that the retaining clamp for the power plug is fixed 
    firmly.
    CAUTIONUse caution to ensure that the power cable does not 
    disconnect during system use.
    If the system is accidentally unplugged, data may be lost. 
    						
    All GE manuals Comments (1)