    							June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
    3 - 45
    3
    (3) After winding the wires around the pulleys, atta ch the wire holder jigs not to loosen the wires.
    Notes: 
     When the wire holder jig is attached, make sure th at the wire is not shifted or loosened.
     The wire should come out of the slot of the wire h older jig and be passed through between the 
    arm and the jig.
     Fig.3-34
    Arm
    Wire holder jig 
    						
    							e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC
    3 - 46
    3.7.2 Lens unit
    [A] Replacing the lens unit 
     The lens unit must not be readjusted and some part
     of its components must not be replaced in the 
    field since the unit is precisely adjusted. If any  of the components is defective, replace the whole 
    unit.
     When replacing the unit, do not loosen or remove t he 4 screws indicated with the arrows.
     Fig.3-35
     Handle the unit with care. Do not hold the lens and adjusted part (hold the unit as shown below).
     Fig.3-36 
    						
    							June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
    3 - 47
    3
    [B] Adjustment of the magnification ratio of the lens
    Notes:   Perform this adjustment only when the lens unit is  taken off or replaced.
     Make sure that the primary scanning reproduction r atio (printer section) is correct before this 
    adjustment.
    (1) Place a ruler on the original glass (in the prim ary scanning direction) and make a copy on A4/LT-
    sized paper at 100% reproduction ratio.
    (3) If each mark on the rulers differs, perform the  adjustment with the following procedures.
     (2) Compare the copied ruler with the actual 
    ruler.
     Fig.3-37
    (1) Take off the original glass and lens cover. 
    (2) Loosen 2 screws fixing the lens unit.
     Fig.3-38
    Feeding Direction
    Actual ruler
    Copied ruler
    Lens unit
    Screw 
    						
    							e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC
    3 - 48
    (3) Slide the lens unit to the right or left directi on using the marks on the lens base as a guide. (Sl ide 
    right when the copied ruler is magnified and slide  left when the copied ruler is demagnified.)
    The following table shows how the reproduction rati o difference between the copied ruler and 
    actual ruler corresponds to the movement amount of  the lens unit.
     Fig.3-39
    Note: Note: 
    Fine adjustment can be made in the “Reproduction ra tio of primary scanning direction (printer)”. 
    on the copied ruler and actual ruler match.
    (4) Tighten 2 screws fixing the lens unit. 
    (5) Attach the lens cover and original glass. Make a  copy to confirm the reproduction ratio.
    (6) Repeat the procedure 1 to 5 until the marks on t he copied ruler and actual ruler match.
    Reproduction-ratio error Movement amount of unit
    0.1% 0.5 mm
    0.2% 0.9 mm
    0.3% 1.4 mm
    0.4% 1.8 mm
    0.5% 2.3 mm
    0.6% 2.7 mm
    0.7% 3.2 mm
    0.8% 3.6 mm
    0.9% 4.1 mm
    1.0% 4.5 mm
    Lens unit 
    						
    							June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
    3 - 49
    3
    3.8 Adjustment of the Paper Feeding System 
    3.8.1 Sheet sideways deviation caused by paper feedi ng
    
    The center of the printed image shifts to the front  
    side.   Move the guide to the front side (Arrow 
    (A) direction in the lower figure). The center of the printed image shifts to the rear 
    side. 
     Move the guide to the rear side (Arrow 
    (B) direction in the lower figure).
     Fig.3-40  Fig.3-41
    Bypass feeding 
    1) Loosen the screen.
    2) Move the entire guide to the front or rear side.
    3) Tighten the screw.Drawer feeding
    1) Loosen 2 screws.
    2) Move the entire guide to the front or rear side.
    3) Tighten the screws.
     Fig.3-42
     Fig.3-43
    Feeding direction
    Center
    [Rear]
    [Front]Feeding direction Center
    [Rear]
    [Front]
    (A) (B)
    ( B )
    (
    A )
    05/07 
    						
    							e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC
    3 - 50
    3.9 Adjustment of Developer Unit 
    3.9.1 Doctor-to-sleeve gap
    Adjustment tool to use: Doctor-sleeve jig 
    
    (1) Perform the adjustment code “05-280”. 
    (2) Take out the process unit from the equipment.
    (3) Take out the developer unit from the process uni t.
    (4) Remove 2 screws and take off the developer  material cover and discharge the developer  
    material.
    Note: Note: Discharge the developer material from the  
    rear side, being careful not to let it be scat- 
    tered on the gear.
     Fig.3-44
    (5) Turn the adjustment screw to widen the gap 
    so that the jig can be inserted in it.
    (Turning the screw clockwise widens the  
    gap)
     Fig.3-45
    Developer 
    material cover
    Screw 
    						
    							June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
    3 - 51
    3
    (6) Insert the gauge with the thickness “0.45” of  the doctor sleeve jig into the gap between  
    the developer sleeve and doctor blade after 
    lifting up the toner scattering prevention  
    sheet. 
    Adjust the screws with the doctor blade to  
    push the doctor sleeve jig lightly.
     Fig.3-46
    (7) Insert the gauge “0.40” of the doctor sleeve 
    jig into the gap between the developer 
    sleeve and doctor blade. Confirm that the jig 
    moves smoothly to the front and rear side,  
    and the gauge “0.50” cannot be inserted into  
    the gap.
     Fig.3-47
    (8) Confirm that the side seals are attached on the toner scattering prevention sheet.
     Fig.3-48
    ScrewDoctor sleeve jig
    Toner scattering 
    prevention sheet
    Developer 
    sleeve
    Doctor sleeve jig
    Side seal Toner scattering 
    prevention sheet 
    						
    							e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC
    3 - 52
    (9) Attach the developer material cover and  tighten 2 screws.
    Note: Note: After the developer material has been  
    replaced, adjust the auto-toner sensor. 
    (See   P.3-1 3.1 Adjustment of Auto-Toner 
    Sensor.)
     Fig.3-49
    Developer 
    material cover 
    						
    							June 2004 © TOSHIBA TECe-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
    3 - 53
    3
    3.10 Adjustment of the RADF (MR-3016) 
    3.10.1 Adjustment of RADF position
    It is mainly performed at the installation. It is a lso required when the RADF is dislocated for some re a-
    son such as moving the equipment. 
    Remove the platen sheet during adjustment.
    
    (1) Open the RADF and then attach 2 position- ing pins to the equipment.
    (The positioning pins have been attached at 
    the rear of the right-hand hinge of the RADF.)
     Fig.3-50
    (2) Close the RADF to check that the positioning  pins fit smoothly into the holes on the RADF.
    If they do not, adjust them according to the 
    following procedure.
     Fig.3-51
    (3) Loosen the stepped screw 1 turn and 2 screws on the adjustment plate a half turn 
    (status of temporary fixing).
     Fig.3-52
    Positioning pin
    1 turn Half turn 
    						
    							e-STUDIO200L/202L/230/232/280/282 ADJUSTMENTJune 2004 © TOSHIBA TEC
    3 - 54
    (4) Remove the stepped screw at the rear of  right-hand hinge.
     Fig.3-53
    (5) Open the RADF, and then loosen 2 hand screws 1 turn (status of tentative fixing).
     Fig.3-54
    (6) Remove the positioning pin at the front side.
    Close the RADF to fit the positioning pin into  
    the hole at the rear side of the RADF. While  
    peering inside from the front side, fit the posi- 
    tions of the pin and hole by moving the  
    RADF right and left.
     Fig.3-55
    Screw 
    						